Linear Prox-Pad User Manual

Prox.Pad® Proximity Reader/Keypad Access Control End User Guide
NOTE: This End User Guide is designed as a “quick reference” document for Prox.Pad end users, especially for initial installations or new users. It is not intended for routine use, and does not replace the more comprehensive information supplied in the separate Prox.Pad Installation/
Programming Manual.
Only the most basic information about monitoring or diagnosing the unit’s operating state is included. Also included is information on how to contact your unit’s installer for assistance.
CONTACTING YOUR INSTALLER
If service is ever required for your Prox.Pad unit or you require operational assistance of any kind, this chart is provided. It is highly recommended that you fi ll in the right-hand columns before the installer leaves your facility following an initial installation.
Contact Information Details
Installation Company:
Address 1:
Address 2 (optional):
City, State, Zip Code:
Telephone Number:
Fax Number:
E-Mail Address/Web Site:
Installer’s Name:
Initial Installation Date:
Your Master Code (after default below is changed):
PROX.PAD DEFAULT SETTINGS
Parameter Default Setting
Master Code (user one) 1234*
Main Relay Energizes for Five (5) seconds
Audible Keypress Feedback ON
Local Propped Door Sounder Activates after Thirty (30) seconds
Local Forced Door Sounder Activates for Ten (10) seconds
Part No. 6-055677, Rev 1.2
1
Prox.Pad® End User Guide
LED INDICATORS/SOUNDER OPERATIONS
LED or Sounder
Yellow LED
Bi-color LED
Visual/Audible Condition
Slow blink Unit is in Program mode
Rapid blink
Steady Program error; to clear, press *
Very rapid blink
Steady red Strike is locked
Steady green Strike is energized (timed or latched)
Solid green with red fl icker
Red/green alternating
Red blink
Description
Verify mode is active (checking that the last two values in sequence match)
Memory (eeprom) erase is in progress (commands 40/46, loop-back)
Strike toggle is unlocked and user lockout active
Awaiting second PIN during “Card AND Code” access attempt
User lockout is active and strike locked; red LED drops out for 100 ms every second; normal users cannot change the state of the relay
Sounder
Short beep (100 ms) every 2 seconds
Sounder 1/2 sec on, 1/2 sec off
3 rapid beeps after code entered or card presented
3 slow beeps (250 ms), then single beep
1 single beep Valid card access
Propped door is active
Forced door is active
Code or Card is not found
Self-test is complete
QUESTIONS OR PROBLEMS
If you have any questions about Prox.Pad operation, or encounter any installation problems, contact your Prox.Pad installer as noted on page 1.
2
Part No. 6-055677, Rev 1.2
Loading...