Linear MT9215S, MT9215 User Manual

1
5.2
6
.0
7
.6
3.0
1.3
1.3
0.5
Dia.
16.5
6.5
Detail A
mm
in
306.8
12.08
25.4
6.9
74.7
2.94
37.3
1.47
88.9
3.50
73.2
2.88
138.3
5.45
Detail A
See Detail A
See
See Detail B
INDOOR/OUTDOOR
FEED-THROUGH HOUSING MOUNTS
MT9215-24H
MT9215
MT9215S
I N STALLATION AND O P E RATING I N STRUCTIONS
MT9219
SAFETY PRECAUTIONS
Top
Bottom
he exclamation point within an equilateral triangle
T is intended to alert the user to presence of impor­tant operating and maintenance (servicing) instruc­tions in the literature accompanying the appliance.
SECURITE
Le point d'exclamation à l'intérieur d'un triangle
quilatéral avertit l'utilisateur de la présence d'in-
é structions importantes d'utilisation et de mainte­nance dans la documentation accompagnant l'ap­pareil.
SICHERHEITSVORKENHRUNGEN
Das Ausrufezeichen in dem gleichseitigen Dreieck ist dazu da, den Benutzer auf wich-tige Inbetriebnahme- und Instandhaltungs-vorschriften hinzuweisen, die dem Gerät in Form einer Broschüre beigelegt sind.
PRECAUCIONES DE SEGURIDAD
El símbolo de exclamación dentro de un triángulo equilátero, se muestra con el objetivo de alertar al ususario de que instrucciones de operación y man­tenimiento importantes acompañan al equipo.
1 UNPACKING
Unpack carefully.This is mechanical equipment and should be handled with care.
The MT9215S has been designed specifically for the HS9480 series housings, while the MT9215-24H, MT9215 and MT9219 can be used with the HS9480, HS9483, and HS9488 series camera housings.All mounts come fully assembled.
4 INSTALLATION
4.1 Installation of the MT9215-24H
1. Determine a secure wall mounting location.
ARNING: Do not mount in an inverted position.
W
2. Caution:
a. For a secure installation use six (6) bolts (not
included). The bolts should extend through the mounting surface and be secured with nuts, lock washers, and flat washers on the opposite side.
b. If studs are used, they should be anchored in
concrete or welded to a steel backer plate.
c. If the wall mount is attached to wood or to a blind
structure (with no access to the rear), make certain that the mounting fasteners have a out strength of 600 pounds.
WARNING: All mounts are designed to support a load only in a vertical direction. Mounts MUST be positioned as shown under SPECIFICATIONS.
3. For ease of installation, locate the bottom mounting holes first. Install the bolts (or studs) into the wall surface.
WARNING:The MT9215-24H must be mounted with the slotted mounting holes of the wall plate at the bottom.
minimum pull-
Check for the following items:
n Verify the unit model number. n Instructions for Use.
If an item appears to have been damaged in shipment,replace it properly in its carton and notify the shipper. If any items are missing, notify Aigis Mechtronics.The shipping carton is the safest container in which the unit may be transported. Save it for possible future use.
2 SERVICE
er needs r
If the unit e contact Aigis Mechtronics.
v
epair service, the customer should
3 DESCRIPTION
MT9215-24H 79-cm (30-in), MT9215 30-cm (12-in), MT9215S 18-cm (7-in), Feed-through Mounts.
The MT9215, MT9215S and the MT9219 are indoor/outdoor mounts designed for fixed camera or camera housing installations up to 9 kg (20 lb) rated load.The MT9215-24H is designed for fixed camera or camera housings installation up to 4.7 kg or (10.5 lbs). All models are made of lightweight aluminum and feature welded construction, providing an extremely rigid camera mount.
and MT9219 40-cm (15-in)
4. Reseat the MT9215-24H on the bolts (or studs) using the bottom slotted holes, then locate the upper mounting holes and drill into the wall surface.
5. Install the upper bolts (or studs) through the wall mount and into the wall surface. Tighten upper and lower bolts (or studs) securely.
The
Note: 10 mm (3/8 in).
6. To mount the camera or camera housing: a. Mount camera with 2 - 1/4-20 bolts and lock
b. Mount housings with 2 - 1/4-20 bolts and
c. Lock mount head in position by using the supplied
2
minimumdiameter bolt (or stud) r
washers (not furnished) in the 2 holes of the adjustable head. and out through the hole near the base.
lockwashers (not furnished).Feed wires through center hole and out through the hole near the base.
1/8-inch long-arm hex wrench to tighten screws.
Feed wires through the center hole
equir
ed is
4.1 Installation of the MT9215, MT9215S and
24.0
7.0
30.1
7.0
8.9
See Detail A
See Detail B
15.2
6.0
7.6
3.0
1.3
0.5
1.3
0.5
mm
in
1.3
0.5
Dia.
(3 Places)
16.5
6.5
Detail A
23.9
0.94
25.4
1.00
12.7
0.50
6.9
0.27
74.7
2.94
37.3
1.47
88.9
3.50
73.2
2.88
7.9
0.31
Detail B
the MT9219
1. Determine a secure wall mounting location.
WARNING: Do not mount in an inverted position.
2. Cautions:
a. For a secure installation, use four 8-mm (5/16-in)
diameter fasteners (not included). Use stainless
teel or zinc plated fasteners.
s
b. If bolts are used, they should extend through the
mounting surface and be secured with flat washers, lock washers, and nuts on the opposite side. Each bolt must have a minimum pull-out strength of 200 kg (450 lb).
c. If studs are used, they should be anchored in
concrete or welded to a steel backer plate. Each stud must have a minimum pull out strength of 200 kg (450 lb).
d. If the wall mount is attached to wood or to a blind
structure (with no access to the rear), each fastener must have a minimum pull-out strength of at least 200 kg (450 lb)
5 SPECIFICATIONS
5.1 MT9215-24H 79-cm (30.1-in) Indoor/Outdoor Feed-through Mount
Maximum Load: 4.7kg (10.5 lb). Mounting Head:Adjustable. 360° pan, 180° tilt. Finish: Dark mushroom. Approx.Weight: .9 kg (2 lb). WARNING: All mounts must be mounted as shown.
WARNING: All mounts are designed to
.
support a load only in a vertical direction. Mounts MUST be positioned as shown under SPECIFICATIONS.
3. Locate the four holes or stud locations using the flange as a template (four holes equally spaced on a 69.9-mm (2-3/4-in bolt circle).
4. Feed wires through the large hole in the flange or through the slot on the surface where the camera housing mounts.
5.
Install the mount using bolts or studs at least 8-mm (5/16-in) in diameter.
6. To mount the camera or camera housing:
a. Mount camera with a 2-1/4-20 bolts and lock
washers (not furnished) in the 2 holes of the adjustable head. Feed wires through the center hole and out through the hole near the base.
b. Mount housings with 2 - 1/4-20 bolts and
lockwashers (not furnished). Feed wires through center hole and out through the hole near the base.
c. Lock mount head in position by using the supplied
1/8-inch long-arm hex wrench to tighten screws.
MT9215-24H Feed-through Mount
3
8.9
0.35
88.9
3.50
mm
in
306.8
12.08
23.9
0.94
25.4
1.00
12.7
0.50
6.9
0.27
74.7
2.94
37.3
1.47
88.9
3.50
73.2
2.88
7.9
0.31
138.3
5.45
Detail A
See Detail A
Detail B
See Detail B
See Detail B
88.9
3.50
8.9
0.35
mm
in
179.8
7.08
138.3
5.45
23.9
0.94
25.4
1.00
12.7
0.50
6.9
0.27
74.7
2.94
37.3
1.47
7.9
0.31
73.2
2.88
88.9
3.50
8.9 .35
Detail A
Detail B
See Detail B
See Detail A
391
15.4
mm
in
234
9.2
157
6.2
5.2 MT9215 30-cm (12-in) Indoor/Outdoor Feed-through Mount
Maximum Load: 9 kg (20 lb).
ounting Head:Adjustable. 360° pan, 180° tilt.
M Finish: Dark mushroom. Approx.Weight: 0.4 kg (0.9 lb). Accessory for MT9215: MT9213 Pole Mount Adapter.
ARNING:All mounts must be mounted as shown.
W
MT9215S Feed-through Mount
MT9215 Feed-through Mount
5.3 MT9215S 18-cm (7-in) Indoor/Outdoor Feed-through Mount
Maxim Mounting Head: Finish: Dark mushroom. Appr Accessory f WARNING: All mounts must be mounted as shown.
um Load:9 kg (20 lb).
x.Weight
o
or MT9215S:
©2006 Aigis Mechtronics 1124 Louise Road, T
Data subject to change without notice
360°
.
Adjustable
0.3 kg (0.7 lb).
:
MT9213 Pole Mount Adapter
336.785.7740 Fax:
el:
tilt.
pan, 180
Winston-Salem,
°
336.785.7744
.
NC 27107-5450
5.4 MT9219 40-cm (15-in) Indoor/Outdoor Feed-through J-mount
Maximum Load: 9 kg (20 lb). Mounting Head:Adjustable. 360° pan, 180° tilt. Finish: Dark mushroom. Approx.Weight: 0.55 kg (1.2 lb). WARNING: All mounts must be mounted as shown.
MT9219 Feed-through J-mount
100 0013 002 AIG 11/06
Printed in U
.S.A.
Loading...