MPORTANT
PLEASE READ AND FOLLOW
THESE INSTRUCTIONS
These instructions contain Warning and Caution
statements. This information is important for safe
and efficient installation.
Always read and follow all Warning and Caution
statements!
WARNING
!
States a hazard that may cause serious
injury or death if precautions are not
followed.
CAUTION
!
Signals a situation where minor injury of
product damage may occur if you do not
follow instructions.
IMPORTANT
This highlights information that is especially
relevant to a problem-free installation.
Make sure incoming voltage is the same as the unit
rating.
To reduce the risk of fire, electric shock, or
personal injury, installation work and electrical
wiring must be done by a qualified electrician
in accordance with all applicable codes and
standards, including fire-rated construction.
A delight in freshness
ii
WF1051 / EWTNes 2956
TO THE INSTALLER
It is very important that the guidelines and
instructions are followed in the manual to ensure
proper installation and operation of the unit. The
Installation Guidelines section contains important
information for making sure the installation is
correct. Read and understand all the information in
Installation Guidelines, and in this manual before
the unit is installed.
• Floors can support refrigerator’s weight plus
approximately 1200 pounds (544 kg) of food
weight.
• Finished kitchen floor height has to be level.
Appliance must be shimmed to the floor level if
the floor heights are not equal to make sure air
vents are not obstructed.
• Remove anything attached to rear or side walls
that can obstruct refrigerator opening.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
Do not install this unit next to any other refrigerator
or freezer except another Liebherr model. Liebherr
models are designed to allow side-by-side
installation. They are equipped with a heating
element to eliminate condensation when units are
installed side by side. Installing this unit next to any
other refrigerator or freezer can cause condensation
or cause damage to the Liebherr unit.
WARNING
!
ELECTROCUTION HAZARD
Electrical Grounding Required. This
appliance is equipped with a three-prong
(grounding) polarized plug for your
protection against possible shock hazards.
DO NOT remove the round grounding
•
prong from the plug.
DO NOT use a two-prong grounding
•
adapter.
DO NOT use an extension cord to
•
connect power to the unit.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp (20 Amp for side-byside installation) fused electrical supply is required.
We recommend using a dedicated circuit for this
appliance to prevent electrical overload. Follow
the National Electrical Code and local codes and
ordinances when installing the receptacle.
Blocking For Safety
The anti-tip brackets must be installed to prevent
the unit from tipping after it is installed. Refer to
Blocking For Safety.
Electrical Requirement
If codes require a separate grounding circuit to be
used, have a qualified electrician install the circuit.
WARNING
!
Do not ground to a gas pipe. Check with a
qualified electrician if you are not sure the
appliance is properly grounded. Do not
have a fuse in the neutral or grounding
circuit.
WARNING
!
ELECTRICAL SHOCK HAZARD
• Electrically ground refrigerator.
• Do not use an extension cord.
• Failure to follow these instructions
could result in fire or electrical shock.
Unit Venting
DO NOT restrict the air flow. Air flow must be
provided for the unit to operate. The factory air
vents provide 31 square inches (200 cm²) of air
flow per unit. If you are replacing the factory air
vents with an overlay, the air flow must be the
same or greater than the factory air vents.
WF1051 / EWTNes 2956
A delight in freshness
3
P
LANNING
I
NFORMATION
Cabinet Opening Dimensions -
Figure 1
Allow units to open a minimum of 90° to prevent
problems removing drawers. With the door
opening 90°, you may have to move drawers
slightly to clear the door interior.
Refer to the minimum door clearances in the PreInstallation Specifications chart.
• Allow for a minimum 3-3/4" (95 mm) filler, for
corner installations, so the door can open to 90°.
If you’re using raised panels, consider using a
wider filler.
IMPORTANT
Refer to the full scale illustrations at the end
of this section for specifics on door openings
and filler size alternatives.
"
"
3"
(76mm)
"
"
"
Figure 1
"
"
A delight in freshness
4
WF1051 / EWTNes 2956
WF1051 - Figure 2
P
LANNING
I
NFORMATION
WF1051 / EWTNes 2956
Figure 2
A delight in freshness
5
P
LANNING
Side-By-Side WF1051 and RB1400 - Figure 3
I
NFORMATION
Figure 3
A delight in freshness
6
WF1051 / EWTNes 2956
P
The factory setting for the door to swing open
is 130°. Use this illustration to ensure other
cabinets or counters do not interfere with the
door opening.
LANNING
I
NFORMATION
130°
WF1051 / EWTNes 2956
A delight in freshness
7
Loading...
+ 20 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.