Installation
Instructions
For Free Standing NoFrost
Combined Refrigerator-Freezers
CS 16
7080 009-00
IMPORTANT
PLEASE READ AND FOLLOW
THESE INSTRUCTIONS
These instructions contain Warning and Caution
statements. This information is important for safe
and efficient installation.
Always read and follow all Warning and Caution
statements!
States a hazard that may cause serious
injury or death if precautions are not
followed.
Signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
Contents ...................................................... Page
Installation
Dimensions ........................................................ 4
Leveling the Refrigerator ................................... 4
Reversing Door Hinges ...................................... 5
Installing ............................................................. 6
Blocking For Safety .................................................. 7
IMPORTANT
This highlights information that is especially
relevant to a problem-free installation.
Make sure incoming voltage is the same as the unit
rating.
To reduce the risk of fire, electric shock, or personal
injury, installation work and electrical wiring must
be done by a qualified electrician in accordance
with all applicable codes and standards, including
fire-rated construction.
TO THE INSTALLER
It is very important that the guidelines and
instructions are followed in the manual to ensure
proper installation and operation of the unit. The
Installation Guidelines section contains important
information for making sure the installation is
correct. Read and understand all the information in
Installation Guidelines, and in this manual before
the unit is installed.
2
INSTALLATION GUIDELINES
Area Requirements
Verify the following:
• Floors can support refrigerator’s weight plus
approximately 1200 pounds (544 kg) of food
weight.
• Finish kitchen floor height is level. Refrigerator
must be shimmed to the floor level if the floor
heights are not equal to make sure air vents are
not obstructed.
• Remove anything attached to rear or side walls
that can obstruct refrigerator opening.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
Do not install this refrigerator-freezer next to any
other refrigerator or model except another Liebherr
model.Liebherr models are designed to allow sideby-side installation.They are equipped with
a heating system to eliminate condensation when
refrigerators or freezers are installed side-by-side.
Installing this refrigerator-freezer next to any other
refrigerator or freezer can cause condensation or
cause damage to the Liebherr refrigerator-freezer.
ELECTRICAL SHOCK HAZARD
• Electrically ground refrigerator.
• Do not use an extension cord.
• Failure to follow these instructions
could result in fire or electrical shock.
ELECTROCUTION HAZARD
Electrical Grounding Required. This
appliance is equipped with a three-prong
(grounding) polarized plug for your
protection against possible shock hazards.
DO NOT remove the round grounding
•
prong from the plug.
DO NOT use a two-prong grounding
•
adapter.
DO NOT use an extension cord to
•
connect power to the unit.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp (20 Amp for side-byside installation) fused electrical supply is required.
We recommend using a dedicated circuit for this
appliance to prevent electrical overload. Follow
the National Electrical Code and local codes and
ordinances when installing the receptacle.
Electrical Requirement
If codes require a separate grounding circuit to be
used, have a qualified electrician install the circuit.
Do not ground to a gas pipe. Check with
a qualified electrician if you are not sure
the appliance is properly grounded. Do not
have a fuse in the neutral or grounding
circuit.
Blocking For Safety
The anti-tip brackets must be installed to prevent
the unit from tipping after it is installed. Refer to
Blocking For Safety.
Unit Venting
DO NOT restrict the air flow. Air flow must be
provided for the unit to operate. The factory air
vents provide 31 square inches (200 cm
flow. If you are replacing the factory air vents with
an overlay, the air flow must be the same or greater
than the factory air vents.
2
) of air
3