LG EAY62171601, EAX63729001 Schematic

11SP 4247” LCD TV Power specification
Specification
Specification
Rev 1.3
6
Date: 2012. 08. 15
11SP 4247” LCD TV Power specification
1. INTRODUCTION
1.1 Scope
This approval is the description related to every electrical and structural specifications and reliability For Power Supply Unit used on 4247 inch LGE LED TV.
1.2 Customers product related items
Product : Power Supply Unit Part code : EAY62171601
1.3 Product name
Product name : LGP4247-11SPL Revision code : 1.3
2. SPECIFICATION
Rev 1.3
2.1 Input Requirements
Nominal Input Voltage AC 100V to AC 240V Input Voltage Variation AC 90V to AC 264V
Under 3.5Arms . (at 100Vac & Nominal Load)
Input Current
Under 1.5Arms . (at 240Vac & Nominal Load)
Nominal Frequency 50 / 60 Hz Frequency Variation Range 47 Hz to 63 Hz Phase Single Leakage Current 0.7mA_peak. (100Vac ~ 240Vac) Surge Immunity ±
4kV / 1000ns / 0˚
to 360˚
Hold-up Time More than 20ms at 100Vac and maximum output load Lightning Surge 2kA Normal, Common Mode
80A zero-peak max
Inrush Current
at cold start and any specified line, load, temperature conditions.
2.1.1 Power Factor over than 0.9 at 90 – 264Vac & max load condition
7
Date: 2012. 08. 15
11SP 4247” LCD TV Power specification
2.2 Power Output Characteristics
Rev 1.3
Output
3.5V
Voltage
Variable range
[V]
0.09W Under(6mA) - -
Rated Current
(Min, Max)
[Amean]
Voltage
Regulation
[V]
Ripple
Voltage
[mVp_p]
3.325V ~ 3.675V
(STBY)
12V 11.4V ~ 12.6V 3 (0.3~3 ±
24V 22.8V ~ 25.2V 4.1 (0.1~4.1) ±
2 (0.001~2) (ON condition) ±
5% 250 mVp_p
5% 350 mVp_p
5% 500 mVp_p
* On Condition : In a moment of Power_ON Signal activated, the current of 3.5V output should be
limited within 40mA(Max) at LCD TV condition for stability.
Do not turn “Power_ON” Signal on at the load condition of 3.5V output, more than 40mA.
* Total regulation for each output circuit includes the results of input voltage variation,
load variation, warm-up drift and temperature change.
* The following instruments shall be used for measuring ripple noise.
1. Probe having impedance ratio of 1:1.
2. Oscilloscope having frequency characteristic of 100MHz or more.
- Test Point : power output each pin
Add Electrolytic Capacitor 47+ 0.1
Power Supply Unit
Output Voltage
700mm
Ripple and noise are measured at the end of output cable which are added a 0.1uF ceramic
capacitor and 47uF electrolytic capacitor. ( connected parallel )
+
Load
Oscilloscope Measurement point
* Power turn on system (Only E/Load condition)
If Main Board is opened, that is electrical load condition, drive on signal must be turn on after about 1.5s behind power on signal
8
Date: 2012. 08. 15
11SP 4247” LCD TV Power specification
2.2.1 Stand By Power Consumption
Output Voltage 3.5V (STBY) 12V 24V Load [A] 0.006 Don’t Care (Power-Off) Wattage [W] Less than 0.09Under (230Vac / 50Hz)
2.3 Environment Requirement
Operating Temperature Range -10to 40
(60:No Hardware Failure, TV SET Condition) Operating Humidity Range 30 to 85 % Storage Temperature Range -25 to 85 deg. Storage humidity Range 5 to 90 %
Rev 1.3
MTBF
50,000 hour
(Mean Time Between Failure) Cooling Condition Natural Air Shock 98
Shock test consists of pivoting the power supply, from one edge of it’s bottom side, on a flat surface
(such as wood having thickness of 10mm or more) and allowing the opposite edge to fall from a height of 50mm to this surface.
The test is performed three times on each edge of the bottom side of the power supply
2.4 Dielectric Strength Voltage and Insulation Resistance
Dielectric Strength Voltage
AC-DC 1.5K VAC 3 SEC 10 mA. Between Primary and All Secondary Circuits.
Safety
Insulation Resistance
Insulation resistance shall be more than 8M ohm (at DC 500V) Between Primary Live, Neutral line and Secondary.
* Above tests are performed at room temperature in non-condensing atmospheric
conditions
* Frame grounds are connected to secondary circuits.
2.5 Burn-in
More than 0.5 hours at 45℃(±5℃), Normal input voltage.
AC on/off must be test 1 time after burn-in. 80% Load of specification.
9
Date: 2012. 08. 15
Loading...