LG BSNQ126J2K0, HSN09ISP Owner’s Manual

LG BSNQ126J2K0, HSN09ISP Owner’s Manual

MFL69284015

Note

1.Exterier size on the drawing is cutting line.

2.To be approved by Engineering Department before production.

3.Shape and size of contents should be based on the film or sample given by designer.

4.The Part should not contain prohibited sustances (Pb,Cd,Hg,Cr+6,PBB,PBDE) and the details comply with LG(65)-B-3514

5.Samples be the same as the actual production

6.(1) & (2) use Front : LG smart Size 6pt Regular.

-(1) is Revision No.on cover page by refer revision detail of each part.

-(2) is Date of modify (Month.Year)

7. A is barcode P/No. by refer P/No.of drawing Front : C39HrP24DhTt , Size 24 pt Normal.

 

 

 

COVER

PAGE

 

 

EXAMPLE

 

 

 

 

 

A

A

 

 

 

REV : (1) (

(2) )

 

 

REV : (1) ( (2) )

 

 

 

 

7.Pantone color of LG

-Red : 207C ( C:0 M:100 Y:43 K:19 )

-Gray : 431C ( C:0 M:0 Y:0 K:70 )

8.LG Logo : Grid & Clear Space

0.15X

X

0.225X

0.016X

0.15X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.15X

0.175X

0.65X

X

0.175X

0.2X

0.15X

8.1. Logo/3D horizorizontal logo with tangine.

Minimun size : 12mm

Specification

PRINTING SJ GGRD SJ SK Mosquito Export model

(Remote AKB74515405) English 2016

 

 

 

Language

English

 

 

Material

White bond paper 70g

 

 

Color

Black&White (monochrome)

 

 

Size (W x H)

148.5 mm X 210 mm (A5)

 

 

Page

24 pages

 

 

Revision

Rev : 00 (08T16)

 

 

Model apply

Export model

 

 

8.2. Logo/3D horizorizontal logo

Minimun size : 10mm

8.3. Logo/2D horizorizontal logo

Minimun size : 4 mm

9. Front : LG Smart font, For languages that cannot apply the LG Smart Font, should select a font that is the closest to LG Smart Font

22-08-2016 Chalermphorn Khamyan

Manual,Owner

MFL69284015

<![if ! IE]>

<![endif]>ENGLISH

OWNER’S MANUAL

AIR

CONDITIONER

Please read this manual carefully before

operating your set and retain it for future reference.

TYPE : WALL MOUNTED

*MFL69284015*

Rev : 00 (08T16)

2 TIPS FOR SAVING ENERGY

<![if ! IE]>

<![endif]>ENGLISH

TIPs FOR SAVING ENERGY

Here are some tips that will help you to minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below :

Do not cool the indoor excessively. This may be harmful for your health and may consume more electricity.

Block sunlight with blinds or curtains while you are operating the air conditioner.

Keep doors or windows closed tightly while you are operating the air conditioner.

Adjust the direction of the air flow vertically or horizontally to circulate indoor air.

Speed up the fan to cool or warm indoor air quickly, in a short period of time.

Openwindowsregularlyforventilationastheindoorairqualitymaydeteriorateiftheairconditioner is used for many hours.

Clean the air filter once every 2 weeks. Dust and impurities collected in the Air filter may block the air flow or weaken the cooling / dehumidifying functions.

For your records

Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :

IMPORTANT SAFETY INSTRUCTIONS

3

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Always comply with the following precautions to avoid dangerous situation and ensure peak performance of you product.

!WARNING

It can result in serious injury or death when the directions are ignored.

!CAUTION

It can result in minor injury or product damage when the directions are ignored.

!WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

Air conditioner shall be installed in accordance with national wiring regulations.

The information contained in the manual is intended for use qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Thisapplianceisnotintendforusebypersons(includingchildren)withreducedphysical,senaryor mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for theirs safety.

Children should be supervised to ensure that they do not play with the appliance.

When the power cord is to be replaced,replacement work shall be performed by authorized personnel only genuine replacement parts.

Installation

Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Failure to do so may result in electric shock or product failure.

Contact an authorized service center when you install or relocate the air conditioner. Failure to do so may result in serious injury or product failure.

Alwaysuseapowerplugandsocketwithagroundterminal.Failuretodosomayresultinelectric shock or product failure.

Installthepanelandthecoverofthecontrolboxsafely.Failuretodosomayresultinexplosionorfire.

Install a dedicatedelectric outlet and circuit breaker before you use the air conditioner.Failure to do so may result in electric shock or product failure.

Do not modify or extend the power cable.If the power cable or cord has scratches or skin peeled off or deteriorated then it must be replaced.It may result in fire or electric shock.

Be cautious when you unpack or install the air conditioner. Failure to do so may result in serious injury or product failure.

Do not install the air conditioner on an unstable surface or where there may be a danger of it falling.It may result in death, serious injury, or product failure.

<![if ! IE]>

<![endif]>ENGLISH

4 IMPORTANT SAFETY INSTRUCTIONS

<![if ! IE]>

<![endif]>ENGLISH

Operation

Do not let the air conditioner run for a long time when the humidity is very high or when a door or window has been left open. Failure to do so may result in product failure.

Make sure that the power cord is not pulled or damaged while the air conditioner is operating. Failure to do so may result in fire, electric shock, or product failure.

Do not place any objects on the power cord.It may result in electric shock or product failure.

Do not turn on or off the air conditioner by plugging in or unplugging the power plug.It may result in fire or electric shock.

Do not touch, operate or repair the air conditioner with wet hands. It may result in electric shock or product failure.

Do not place a heater or other heating appliances near the power cable. It may result in fire, electric shock, or product failure.

Do not allow water to run into the air conditioner.It may result in explosion or fire.

Do not leave flammable substances such as gasoline, benzene and thinner near the air conditioner. It may result in explosion or fire.

Do not use the air conditioner for an extended period of time in a small place without ventilation. Ventilate the place regularly. Failure to do so may result in explosion or fire.

When there is a gas leak, ventilate sufficiently before using the air conditioner again. Failure to do so may result in explosion or fire.

Unplug the power plug if there is a noise, smell or smoke coming from the air conditioner. Failure to do so may result in explosion or fire.

Stop operating and close the window in storm or hurricane. If possible remove the product from the window before hurricane arrives.

Donottouchtheelectrostaticfilterafteropeningthefrontgrille.Failuretodosomayresultinelectric shock or product failure.

Contactanauthorizedservicecenterwhentheairconditionerissubmergedintowaterduetoflooding. Failure to do so may result in explosion or fire.

Be cautious water could not enter the product.

Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater areusedsimultaneously.Failuretodosomayresultinexplosionorfire,seriousinjury,orproductfailure.

Turnthemainpoweroffandunplugthepowerplugwhenyoucleanorrepairtheairconditioner.Failure to do so may result in death, serious injury, or product failure.

Unplug the power plug when the air conditioner is not used for an extended period of time. Failure to do so may result in product failure.

For inner cleaning, contact an Authorized Service Center or a dealer.

Do not use harsh detergent that causes corrosion or damage on the unit. Harsh detergent may also cause failure of product, fire, or electric shock.

IMPORTANT SAFETY INSTRUCTIONS

5

! CAUTION

<![if ! IE]>

<![endif]>ENGLISH

Failure to do so may result in product failure.

Installation

 

• Make sure to check if there is a refrigerant leak after you install or repair the air conditioner.

 

• Install the drain hose properly for smooth drainage of condensed water. Failure to do so may

 

result in product failure.

 

• Keep level even when installing the product.

 

• Install the air conditioner where the noise from the outdoor unit or the exhaust gas will not

 

inconvenience the neighbors. Failure to do so may result in conflict between neighbors.

 

• When transporting the equipment, there should be at least 2 or more people, or a forklift. It

 

may result in serious injury.

 

• Do not install the air conditioner where it will be exposed to sea wind (salt spray) directly.It may

 

result in product failure.

 

•Donotturnonthebreakerorpowerunderconditionthatfrontpanel,cabinet,topcover,control

 

boxcoverare removedoropened. Otherwise,it may cause fire,electric shock, explosionor death.

 

Operation

 

• Do not expose people, animals or plants to the cold or hot wind from the air conditioner. It may

 

result in serious injury.

 

• Do not use the product for special purposes, such as preserving foods, works of art, etc. It is

 

a consumer air conditioner, not a precision refrigeration system. It may result in death, fire or

 

electric shock.

 

• Do not block the inlet or outlet of air flow.It may result in explosion or product failure.

 

•Donotusestrongcleaningagentsorsolventswhenyoucleantheairconditioner,orspraywater.

 

Use a smooth cloth.It may result in serious injury or product failure.

 

• Never touch the metal parts of the air conditioner when you remove the air filter. It may result

 

serious injury or product failure.

 

• Do not place any objects on the air conditioner.It may result in product failure.

 

• Always insert the filter securely after cleaning. Clean the filter every two weeks or more often

 

if necessary.

 

• Do not insert hands or other objects through the air inlet or outlet while the air conditioner is

 

operating.It may result in electric shock.

 

•Donotdrinkthewaterdrainedfromtheairconditioner.Itmayresultinserioushealthcomplications.

 

• Use a sturdy stool or ladder when you clean, maintain or repair the air conditioner at a height.

 

Failure to do so may result in serious injury or product failure.

 

•Donotmixthebatteriesfortheremotecontrolwithothertypesofbatteriesormixnewbatteries

 

with used batteries. Failure to do so may result in product failure.

 

• Do not recharge or disassemble the batteries. Failure to do so may result in explosion, fire or

 

serious injury.

 

•Stopusingtheremotecontrolifthereisabatteryfluidleak.Ifyourclothorskinisexplosiontothe

 

battery fluid from a leak, wash it off with clean water. Failure to do so may result in serious injury.

 

• If you swallow the battery fluid from a leak. Wash out the inside of your mouth thoroughly and

 

then consult a doctor. Failure to do so may result in serious health complications.

 

6 CONTENTS

<![if ! IE]>

<![endif]>ENGLISH

Contents

2TIPs FOR SAVING ENERGY

3IMPORTANT SAFETY INSTRUCTIONS

7

BEFORE USE

 

 

7

Components

7

- Indoor unit

7

- OUTdoor unit

8Inserting batteries

8Installing the remote control holder

8Operating method

9USING THE REMOTE CONTROL

9Wireless remote control

10BASIC FUNCTIONS

10Cooling your room (Cooling operation)

10Removing humidity (Dehumidifying operation)

10Airing your rooM (Air Circulation operation)

10Adjusting the fan speed

11Adjusting the air flow direction

11Setting the timer

11

- Setting the current time

11

- Turning on the air conditioner

 

automatically at a set time

11- Turning off the air conditioner automatically at a set time

11- CanceLing the timer setting

12Setting sleep mode

12 Advanced FUNCTIONS

12Changing roomtemperature quickly

(JET COOL) (OPTIONAL)

13Indoor air purification (Auto Clean operation)

13Display screen brightness

13Auto operation (Artificial intelligence)

141 TOUCH SOFT AIR OPERATION (Comfort Vane operation)(OPTIONAL)

14Mosquito Away Operation

15Active energy control operation (OPTIONAL)

16Operating the air conditioner without the remote control

16Restarting the air conditioner automatically

16- Disabling auto restart

17MAINTENANCE

18Cleaning the air filter

18Cleaning 3M filter (optional)

19Assemble 3M Filter (optional)

20TROUBLESHOOTING

20 Self-diagnosis function

20 Before requesting service

BEFORE USE

7

BEFORE USE

Components

Indoor unit

Air inlet

Air filter

3M filter (Optional)

 

 

 

 

Front cover

 

 

Signal Receiver

 

 

Display screen

 

 

On/off button

Air outlet

 

 

 

 

Vertical louver

 

Horizontal vane

 

*The feature can be changed according a type of model.

!NOTE

The number of operation lamps and their locations may vary, depending on the model of the air conditioner.

OUTdoor unit

Air inlet

Connecting wires

Air outlet

Piping

<![if ! IE]>

<![endif]>ENGLISH

Base Plate

Drain hose

 

*The feature can be changed according a type of model.

 

Loading...