Karcher FS 2000 User Manual

FS 2000
1.250-101
www.karcher.com
5.959-271 A2002423 02/03
FS 2000 2
Betriebsanleitung 3
Ersatzteilliste 229
Spare Parts List 229
Notice d'instructions 31
Liste des pièces de rechange 229
Istruzioni per l'uso 45
Elenco pezzi di ricambio 229
Gebruiksaanwijzing 59
Reserveonderdelenlijst 229
Instrucciones de servicio 73
Lista de piezas de requesto 229
Manual de instruçoes 87
Lista de pecas sobresselentes 229
ПдзгЯет лейфпхсгЯбт
бнфбллбкфйкб
102
229
Driftsvejledning 117
Reservedelsliste 229
Bruksveiledning 131
Reservedels liste 229
Driftinstruktion 145
Reservdelslista 229
Käyttöohje 159
Varaosalista 229
Üzemeltetési utasítás 173
Cserealkatrészlista 229
Návod k obsluze 187
Seznam náhradních dílů 229
Navodilo za uporabo 201
Seznam rezervnih delov 229
Instrukcja obsługi 215
Lista części zamiennych 229
English FS 2000 17
CONTENTS
For your safety! 18
Personal Protective Equipment 18 Emergency procedures 18
Environmental protection 18
Range of applications 19
Overview 19
Transport 19
Before first-time operation 20
Mounting handle 20 Mounting bracket 20
Each time before operation 20
Checking/closing valves 20 Filling with cleaning agent/disinfectant 21 Connecting to the mains 22
Operation 22
Shampooing/cleaning 23 Spraying/disinfection 23
Each time after usage 24
Dissipating pressure 24 Switching off the cleaner 24 Draining pressure vessel 24 Flushing pressure vessel 26
Care 26
Reccommended cleaning agents 27
Cleaning agent overview 28
Fault tracing instructions 28
Detaching cover 28
Accessories 30
Technical data 30
English FS 2000 18
FOR YOUR SAFETY!
Study operating instructions carefully prior to initial start-up!
Only to be operated by qualified
personnel
Unit must be accompanied by
operating instructions if passed on to third parties
Never make any modifications to
unit
Do not fix hand gun trigger in
position
Do not leave unit unattended
Do not allow children near the
cleaner
Always have damaged piping and
hoses replaced immediately by After-Sales Service
Make sure piping and hoses are
never kinked, routed over sharp edges or trapped
Electrical safety
Class I units are only to be
connected to properly earthed power sources.
All parts carrying electricity in the
work zone must be protected against water jets.
Only connect unit to sockets
provided with 30 mA residual- current-operated circuit breaker.
Operation prohibited in baths and
with user standing in water.
National regulations
Operation in Germany is subject
to the guidelines on liquid-jet units (spraying devices) ZH 1/406 and the accident prevention regulations (UVV) BGV D15 Working with Liquid-Jet Units as issued by the Principal Organisation of the Commercial Employers' Liability Insurance Associations. In line with UVV BGV D15 high-pressure spraying devices must be checked every 12 months by a qualified expert, with the results of checking being recorded in writing. Information can be obtained from your retailer. ZH 1/406 and UVV BGV D15 are available from Carl HeymannsVerlag KG, Luxemburger Str. 449, 50939 Cologne.
Observe appropriate regulations
applicable to operation in other countries.
Commercial applications
In Germany, mobile units for
commercial use are subject to safety checking in accordance with VDE Standards.
Observe appropriate regulations
applicable to units for commercial use in other countries.
Heed appropriate safety
regulations for use at petrol stations or in other hazardous environments.
Safety features
Unit is switched off on exceeding
operating pressure.
Safety valve opens if pressure
switch is defective.
Motor is switched off in the event
of overload/overheating.
Personal Protective Equipment
Hazards associated with cleaning agent!
Observe cleaning
agent/disinfectant manufacturer's notes on safety and handling
Never allow to come into contact
with eyes and skin
Always wear protective clothing,
as well as mask, protective goggles, rubber boots and rubber gloves
Thoroughly wash contaminated
protective clothing with water
Emergency procedures
Heed applicable company
instructions
Observe cleaning
agent/disinfectant manufacturer's notes on safety and handling
ENVIRONMENTAL PROTECTION
Items used when working, such as cleaning agent/disinfectant and contaminated maintenance materials, are to be deposited at a special collection point.
Packaging materials, metal and plastic containers are to be set aside for recycling as appropriate.
English FS 2000 19
RANGE OF APPLICATIONS
Foam generator for mobile low- pressure shampooing and disinfection
Unit is suitable for cleaning/disinfection of rooms and installations in industry/foodstuffs industry, in the hotel and catering sector, in sports and keep-fit centres, in swimming baths, hospitals, rest homes and industrial kitchens. This also includes general building cleaning applications and in particular sanitary and wet room facilities.
Cleaning agent/disinfectant must
be suited to the surface to be treated!
OVERVIEW
1 Hand gun with shampoo lance and fan-jet nozzle 2 Cover with ON/OFF switch and hose connection 3 Handle 4 Bracket with cable holder 5 Pressure vessel
1 Air supply valve 2 Control valve 3 Safety valve 4 Cap 5 Pressure gauge
TRANSPORTATION
Coil up connecting cable Coil up high-pressure hose and attach to handle Place hand gun in holder
Take care not to kink high-pressure hose and connecting cable!
For transportation in vehicle, secure unit with straps to prevent slipping/tilting.
English FS 2000 20
BEFORE OPERATION FOR THE FIRST TIME
Inform retailer immediately of any transportation damage!
Mounting bracket
EACH TIME BEFORE OPERATION
Checking/closing valves
Unit, piping, high-pressure hose
and connections must be in perfect working order!
Mounting handle
Slacken off handle bolts Pull handle out of holders, turn through 180° and re-insert Tighten bolts
Insert bracket
Tighten both wing nuts
Close safety valve
Turn control valve clockwise as far as it will go
Close air supply valve (position across direction of flow)
English FS 2000 21
Filling with cleaning agent/disinfectant
Use is only to be made of
approved products (refer to cleaning agent overview)
Never fill with solvent
(petrol, acetone, thinner etc.)!
Avoid contact with eyes and
skin
Observe cleaning
agent/disinfectant manufacturer's notes on safety and handling
Always wear protective clothing,
mask, protective goggles, rubber boots and rubber gloves
Warning: Chemical reaction hazard!
Unit must be thoroughly cleaned of all residue before switching from acid to alkaline cleaning agents! Pressure vessel will otherwise be damaged by pitting.
An approved, individual range of cleaning agents and disinfectants is available from Kärcher.
Your dealer will be pleased to advise you.
Open air supply valve Open safety valve and dissipate pressure.
Open fastener on pressure vessel
Cap is released inwards Make sure seal does not drop into vessel.
Take out cap
Heed cleaning agent/disinfectant manufacturer's instructions on dilution/mixing!
Warning:
Maximum total filling capacity: 20 l Residual volume in pressure vessel is required as air cushion.
Loading...