Subject
Model
Service Bulletin Ref. No.
(Page.1/1)
2KW-0035 (C044)
[Service Information]
Notes on Replacement of the LK-590A/B Laser Scanner Unit
(LSU)
FS-C2026MFP, FS-C2126MFP, FS-C5150DN, FS-C5250DN,
FS-C2526MFP, FS-C2626MFP, FS-C2026MFP+, FS-C2126MFP+
<Date> February 21, 2012
Topic
The service part LK-590A/B does not have the LSU focus adjuster gear fitted. (Please refer to the photo to the right
below.) However, please note that this part can be installed into the machine without the gear.
Unit installed in the machine Service part
Gear fitted
No gear
Background
The LSU focus for the unit to be installed at the factory is adjusted in the machine and the gear is already fitted
as shown in the photo to the left above. The service part LSU does not have the gear since they are adjusted
outside of the machine using an adjusting tool. When replacing the unit, no gear is necessary. Also, there is no
need to fit the one removed from the old unit.
KMC’s Classification Entire Stock Rework In-Field modification at next visit
n-Field modification by case No modification necessary
Field Measure: Please note the above.
Serial Nos. of the Affected Machines: -----------
European Service & Development Center (ESDC)
KYOCERA MITA Europe B.V.