(Revised Issue 1) (Page 1/5)
Improvement of the Toner Container Drive Section Engagement
(Measures against the Frequent Toner Replacement Message
Display due to the Toner Supply Failure)
FS-C5150DN, FS-C5250DN, FS-C2026MFP, FS-C2126MFP,
FS-C2026MFP+, FS-C2126MFP+, FS-C2526MFP, FS-C2626MFP
KDC’s Classification Entire Stock Rework In-Field modification at next visit
In-Field modification by case No modification necessary
Field Measures:
Please replace the CAM TONER SUPPLY (4 pcs. of No.1) with the new one when the phenomenon described
below occurs.
(Note1) Please refer to another document [Procedure for replacing with the corrective parts] (File name is
“Procedure_D012_2KT_0019_E”) for the procedures how to replace the parts.
(Note2) Along with this work, it is recommended to replace the other corrective parts in the related sections.
For more details, please refer to another Service Bulletin SB-2KT-0019-D012.
Serial Nos. of the Affected Machines: From the available timing in the February 2013* production
* The above is the plan at the present moment. Please note that this information is subject to change.
Service Bulletin Ref. No. 2KT-0021 (D022)
<Date> April 1, 2013
This time, the description with (-->) was revised from the previous information.
<Number of changes: 2> The actual serial numbers were added.
To be informed:
To several issues, we have created a modification kit containing the parts in the <Table.2>.
The Item code of each modification kit is described in the <Table.3>. (Each country has a different item code!)
All latest hardware updates since January are implemented in this kit.
For more details, please refer to the Service Bulletin SB-2KT-0019-D012.
We do not recommend ordering the modification kit in every case, but the price for the kit will be lower than the
parts ordered separately ,which makes the purchase more convenient.
<Table.2> Contents of the modification kit (The yellow marked part is described in this Bulletin.)
KYOCERA Document Solutions Europe
Customer Services & Support Division (CSSD)

(Revised Issue 1) (Page 2/5)
Material
Number
in AS-400
GEMINI MODIFICATION KIT FOR AUSTRIA
GEMINI MODIFICATION KIT FOR BELGIUM
GEMINI MODIFICATION KIT FOR SWITZERLAND
GEMINI MODIFICATION KIT FOR GERMANY
GEMINI MODIFICATION KIT FOR DENMARK
GEMINI MODIFICATION KIT FOR SPAIN
GEMINI MODIFICATION KIT FOR FINLAND
GEMINI MODIFICATION KIT FOR FRANCE
GEMINI MODIFICATION KIT FOR UNITED KINGD
GEMINI MODIFICATION KIT FOR ITALY
GEMINI MODIFICATION KIT FOR NETHERLANDS
GEMINI MODIFICATION KIT FOR NORWAY
GEMINI MODIFICATION KIT FOR PORTUGAL
GEMINI MODIFICATION KIT FOR SWEDEN
GEMINI MODIFICATION KIT FOR SOUTH AFRICA
GEMINI MODIFICATION KIT FOR RUSSIA
GEMINI MODIFICATION KIT FOR INT. SALES
GEMINI MODIFICATION KIT FOR OLIVETTI
GEMINI MODIFICATION KIT FOR TA GmbH
Service Bulletin Ref. No. 2KT-0021 (D022)
<Table.3> item code of modification kit
<Date> April 1, 2013
Customer Services & Support Division (CSSD)
KYOCERA Document Solutions Europe

(Revised Issue 1) (Page 3/5)
Improvement of the Toner Container Drive Section Engagement
(Measures against the Frequent Toner Replacement Message
Display due to the Toner Supply Failure)
<Toner container left side (Drive section)
<When the top tray is fully opened without all toner containers>
[Joint at the machine left side (x4)]
[Joint at the toner container (4 colors)]
Engaged when the
top tray is closed.
Service Bulletin Ref. No. 2KT-0021 (D022)
<Date> April 1, 2013
Topic
When the joint (X) at the machine left side insufficiently engages the joint (Y) at the toner container due to
dimensional variation of the parts or the assembly, the machine drive might not be transmitted to the toner container,
which causes toner supply failure. Also, the toner replacement message might be frequently displayed even if the
toner container was replaced with the new one. Therefore, the following change was made.
Content of Changes
The shape of the CAM TONNER SUPPLY (No.1) thrusting the joint at the main unit in the engaging and
disengaging directions was changed to facilitate the joints engagement of the main unit and the toner container.
(For more details, please refer to the next page.)
* Red lines in the above figure indicate the engagement
shape of the joints (X, Y).
The engagement shape differs depending on the model
and the specs.
*1: Newly registered this time
KYOCERA Document Solutions Europe
Customer Services & Support Division (CSSD)

(Revised Issue 1) (Page 4/5)
Toner motor holder
(Attached to outside
of the left frame)
Hole of the toner container left
guide to insert the joint
<Toner container left side>
(Drive section)
The edges of the entry shape were cut to avoid the contact with
the rib around the joint (Y) of the toner container.
To secure the margin for the joint's
engagement when the toner motor
holder is bent, the snap-fit shape to
hook the toner motor holder was
changed and the length of the arm
was extended by 1 mm.
The outer diameter of the insertion shape was reduced by thinning its
thickness so that the gap margins between the part and the hole to
insert the joint of the toner container left guide can be secured in order
to avoid the contact with the hole to insert the joint.
- Old outer diameter: 16.95 mm (+/-0.04 mm)
- New outer diameter: 16.75 mm (+/-0.04 mm)
Arm length
(Same as the
low side)
Service Bulletin Ref. No. 2KT-0021 (D022)
<Date> April 1, 2013
<Machine left side>
[Part motion when the top tray is opened and closed]
- Top tray open: The CAM TONER SUPPLY thrusts the joint (X) in the disengaging direction as indicated on the
page 1.
(The toner container can be detached by disengagement of the joints.)
- Top tray close: The CAM TONER SUPPLY slides in the engaging direction and the joint (X) of the machine
engages the joint (Y) of the toner container by the pressure of the spring attached inside of the joint (X).
(The machine drive is transmitted to the toner container by engaging the joints, and the toner conveying screw in
the toner container is rotated to supply toner.)
[CAM TONER SUPPLY (No.1)]
(Old) (New)
KYOCERA Document Solutions Europe
Customer Services & Support Division (CSSD)

(Revised Issue 1) (Page 5/5)
Next production
(Not affected until
NHU3300828)
Next production
(Not affected until
NML2X01863)
Next production
(Not affected until
NQ92300115)
Next
production
(Not affected until
NQA2500212)
Service Bulletin Ref. No. 2KT-0021 (D022)
<Date> April 1, 2013
(-->) Serial Nos. of the Affected Machines
KYOCERA Document Solutions Europe
Customer Services & Support Division (CSSD)