Service Bulletin
SB Number:
Subject:
SB 2K3-016
Difcult to pull the Paper cassette outside the Main body
Creation Date: 16/02/2012
FS-6025MFP/6025MFP(B)/6030MFP, FS-C8020MFP/8025MFP,
Model:
PF-470/471
Affected models PF-470/471 FS-6025MFP/6025MFP(B)/6030MFP, FS-C8020MFP/8025MFP
Phenomenon It may be difcult to pull the standard Paper cassette outside the Main body.
Temporary
solution
Permanent
solution
To prevent contact between the Boss and the Base edge, a Guide has been added to the back
of the Paper cassette. (Refer to Service Bulletin 2K3-015 for further details)
1. To prevent contact between the Paper width cursor support point and the Base edge
protection material, the shape of the back of the Paper cassette has been changed.
2. Due to the above mentioned change, the Guide is no longer necessary and has been
discontinued.
Back of the Paper cassette
Added ribs (Marked in blue)
Paper width cursor
support point boss
(Marked in green)
The Guide has been discontinued
Guide
Arm
KMIS Service Department, Kyocera Mita Europe C022 / SB 2K3-016
Page 1 of 2
Parts
Service Bulletin
No. Old Parts
No.
1 302K393171
2K393171
2 303NN93011
3NN93011
3 302K394900
2K394900
Notes: *1. Main body standard Paper cassette and 1ste cassette of the PF.
*2. 2nd Paper cassette (Added for commonality with the standard Paper cassette and 1ste cassette of the PF)
Classication
Field measure When the above mentioned phenomenon occurs, please add the Guide to the Paper cassette
Serial numbers of affected machines
Type Serial number
PF-470/471 Planned from January 2012 production*.
FS-6025MFP/6025MFP(B)/6030MFP, FS-C8020MFP/
8025MFP
The above is the plan at the present moment. Please note that there is a possibility of change after giving this
information.
New Parts
No.
302K393172
2K393172
303NN93012
3NN93012
---------- + PARTS GUIDE BOTTOM
Entire stock rework
(Refer to Service Bulletin 2K3-015 for further details).
Description Q’TY Interchange-
Old New Old New
CT-475 1 1 O O *1
CT-476 1 1 O O *2
1 - X - (Set of the Guide/
CASSETTE ASSY SP
In-eld modication at next visit
Not availble
In-eld modication by case
X
Remarks
ability
Screw/Leaet)
No modication necessary
KMIS Service Department, Kyocera Mita Europe C022 / SB 2K3-016