Service Bulletin
SB Number:
Subject:
SB 2K3-001
Firmware upgrade (Firmware pack 1.01)
Creation Date: 15/02/2011
Model: FS-6025MFP/6025MFP/B/6030MFP
Phenomenon When copying in low temperature environments (14°C or less), the error LED may be rarely
turned on after ejecting the paper, and error code F186 may appear on the operation panel and a
blank page may be printed out.
Cause VSYNC(*1) interrupt signal is not transmitted to the main CPU when processing main charge
adjustment for low temperature, however, the signal for releasing it may not be transmitted after
that, and error code F186 may appear due to the abnormal processing.
(*1) Sweep out timing signal of the image data.
Solution Under the above mentioned condition, the release signal will be transmitted.
Firmware
Type Program No. Version
Upgrade Pack Ver. 2K3_V1.01E 1.01
MAIN 2K3_2F00.001.302 001.302
MMI 2K3_7000.001.300 001.300
ENGINE 2K3_1000.003.003 003.003
IO 2K3_1E00.001.010 001.010
DP 3M8_9500.002.001 002.001
FAX BOOT/APL * 5JR_5500.B01.019 B01.019
Firmware notes *: BOOT: B01.019 / APL: B01.019
Classication
Field measure When the above mentioned phenomenon occurs, please upgrade the rmware to the latest
Serial numbers of affected machines
Type Serial number
FS-6025MFP/6025MFP/B/6030MFP January 2011 production.
The above mentioned changes have been applied to machines produced after the above mentioned production date.
Entire stock rework
version.
In-eld modication at next visit
In-eld modication by case
X
No modication necessary
KMIS Service Department, Kyocera Mita Europe B034 / SB 2K3-001