M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de
M corresponden a México (Ej.
K-12345M)
Français, page ″Français-1″
Español, página ″Español-1″
1230865-2-A
Before You Begin
NOTICE: The K-99695 system controller is required to complete this
installation.
NOTICE: Custom shower configurations may not allow certain
system features to be enabled.
NOTE: For pre-programmed shower configurations, refer to the
guide on the K-99695 controller product page at www.us.kohler.com.
Observe all local plumbing, building, and electrical codes.
Read these instructions and determine all components and
installation locations before beginning installation.
A dedicated water heater, 80 gallon (302.8 L) or larger, per valve
is recommended for this installation.
A tankless (on-demand) water heater is not recommended for this
installation.
Drain requirements: The maximum flow rate per valve is 21
gal/min (79.5 l/min) at 45 psi (310.3 kPa). Use a minimum 3″ (76
mm) single drain, minimum 2″ (51 mm) multiple drains, or a
drain system capable of handling the maximum flow rate for oneor two-valve systems.
Before Operating the System For the First Time:
Download and install the latest software for connected components.
This may take an hour or more to complete based on system
configuration and internet connection speed. Do not disconnect the
power from any components during software download and
installation.
1230865-2-A2Kohler Co.
AC
Power
Controller
Digital
Valve
Router
Ethernet Cable
25' (7.6 m) Data Cable
Internet
Service
Computer
or Tablet
Interface
(Up to Three)
AC
Shower FittingsWater Inlets
Power
Digital
Valve
1. Plan the System
NOTE: The controller powers the interface(s) and controls the
digital valve(s) and other system components.
NOTE: Your system may include installation of one or two digital
valves. A data cable is required for each valve.
NOTE: The data cable length is 25’ (7.6 m). Valve installation
location(s) must be within 24’ (6.1 m) of the controller.
Determine the locations of all components, including shower
fittings. For pre-programmed shower configurations, refer to the
guide found on the product page at www.us.kohler.com.
Refer to the installation guides packed with each product for
specific installation needs.
Kohler Co.31230865-2-A
Tab
Clip
Power
Supply
Grommets
Door
Valve
Data
Cable
Drip Loop
2. Installation
Install the K-99695 system controller and the K-682 valve
according to the instructions packed with the products.
Route the data cable in the wall between the controller and valve
installation locations.
Connect the Cables
NOTE: Make drip loops in all cables and cords.
Press the clips to release and open the door on the valve.
To remove the door, slide the hinge side of the door in either
direction until it slips free.
Connect the data cable to the valve.
Connect the power supply to the valve.
Verify all grommets are in place, then reinstall the door.
To close the door, press on the tabs until the clips snap in place.
1230865-2-A4Kohler Co.
3. Configure the Valve
NOTE: Valve setup requires an installed controller, a computer or
tablet, and a router with active internet service.
NOTE: Valves which have been recently installed, or have not been
used for some time should be exercised before running tests or
setting the maximum temperature.
NOTE: The maximum water temperature to the outlets is limited to
120°F (49°C). The valve will automatically shut down if the
temperature exceeds 120°F (49°C).
To configure valve setup, refer to the guide on the K-99695
controller product page at www.us.kohler.com.
Before Operating the System For the First Time:
Download and install the latest software for connected components.
This may take an hour or more to complete based on system
configuration and internet connection speed. Do not disconnect the
power from any components during software download and
installation.
Troubleshooting
WARNING: Risk of electric shock. Disconnect power before
servicing.
NOTICE: Valve maintenance should be performed by a KOHLER
Authorized Service Representative.
NOTE: For additional valve troubleshooting, refer to the valve
installation guide.
This troubleshooting guide is for general aid only. For service and
installation issues or concerns, call 1-800-4KOHLER.
recommended
actions for the
above issues
correct the
symptom, the
valve or controller
requires servicing.
C. Check the data cable
connection, connect if
needed.
D. Reset the circuit
breaker.
E. Disconnect and
reconnect the power
supply from the
valve.
F.Contact your Kohler
Co. authorized
service
representative.
Warranty
KOHLER®Electronic Faucets, Valves and Controls
FIVE-YEAR LIMITED WARRANTY
Kohler Co. warrants that its electronic faucets, valves and controls will
be free of defects in material and workmanship during normal
residential use for five years from the date the product is installed.
This warranty applies only to electronic faucets, valves and controls
installed in the United States of America, Canada and Mexico (″North
America″).
If a defect is found in normal residential use, Kohler Co. will, at its
election, repair, provide a replacement part or product, or make
appropriate adjustment where Kohler Co.’s inspection discloses any
such defect. Damage caused by accident, misuse, or abuse is not
covered by this warranty. Improper care and cleaning will void the
warranty*. Proof of purchase (original sales receipt) must be provided
to Kohler Co. with all warranty claims. Kohler Co. is not responsible
for labor charges, installation, or other incidental or consequential costs
other than those noted above. In no event shall the liability of Kohler
Co. exceed the purchase price of the faucet, valve or control.
If the electronic faucets, valves or controls are used commercially or are
1230865-2-A6Kohler Co.
Warranty (cont.)
installed outside of North America, Kohler Co. warrants that the
faucet, valve or control will be free from defects in material and
workmanship for one (1) year from the date the product is installed,
with all other terms of this warranty applying except duration.
If you believe that you have a warranty claim, contact your Home
Center, Dealer, Plumbing Contractor or E-tailer. Please be sure to
provide all pertinent information regarding your claim, including a
complete description of the problem, the product, model number, the
date the product was purchased, from whom the product was
purchased and the installation date. Also include your original invoice.
For other information, or to obtain the name and address of the service
and repair facility nearest you, write Kohler Co., Attn: Customer Care
Center, Kohler, Wisconsin 53044 USA, or by calling 1-800-4-KOHLER
(1-800-456-4537) from within the USA and Canada, and
001-800-456-4537 from within Mexico, or visit www.kohler.com within
the USA, www.ca.kohler.com from within Canada, or
www.mx.kohler.com in Mexico.
THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some
states/provinces do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of such damages, so
these limitations and exclusions may not apply to you. This warranty
gives the consumer specific legal rights. You may also have other
rights that vary from state/province to state/province. This warranty
is to the original consumer purchaser only, and excludes product
damage due to installation error, product abuse, or product misuse,
whether performed by a contractor, service company, or the
consumer.
This is Kohler Co.’s exclusive written warranty.
*Never use cleaners containing abrasive cleansers, ammonia, bleach,
acids, waxes, alcohol, solvents or other products not recommended
for chrome. This will void the warranty.
Kohler Co.71230865-2-A
Guide d’installation et d’entretien
Câble de données
Avant de commencer
AVIS: Le module de commande du système K-99695 est requis
pour terminer cette installation.
AVIS: Les configurations de douches personnalisées pourraient ne
pas permettre l’activation de certaines caractéristiques du système.
REMARQUE: Pour les configurations de douches préprogrammées,
consulter la page de produit du module de commande K-99695 au
www.us.kohler.com.
Respecter tous les codes électriques, de plomberie et de
construction locaux.
Lire ces instructions et déterminer tous les composants et les
emplacements d’installation avant de commencer celle-ci.
Un chauffe-eau dédié, de 80 gallons (302,8 L) ou plus par vanne
est recommandé pour cette installation.
Un chauffe-eau sans réservoir (sur demande) n’est pas
recommandé pour cette installation.
Conditions requises pour le drain: Le débit maximum par vanne
est de 21 gal/min (79,5 l/min) à 45 psi (310,3 kPa). Utiliser un
drain unique de 3″ (76 mm) minimum, plusieurs drains de 2″ (51
mm) minimum, ou un système de drain capable de s’adapter au
débit maximum pour les systèmes à une ou deux vannes.
Avant de faire fonctionner le système la première fois:
Télécharger et installer le dernier logiciel pour les composants
connectés. Une heure ou plus peuvent être nécessaires en fonction de
la configuration du système et de la vitesse de connexion Internet. Ne
pas déconnecter l’alimentation électrique des composants pendant le
téléchargement et l’installation du logiciel.
Kohler Co.Français-11230865-2-A
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.