Installation and Homeowners Guide
Underscore Bathroom Heater S300
S300
K-77316T-C-MZ
(Air-care)
KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD,
JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436
( ) 158 200436
1325978-T01-A

-1-
BEFORE YOU BEGIN
©©Copyright Kohler China Investment Co., Ltd. 2016
2016
!
!
!
!
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operation and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information -
.
This product complies with GB 4706.1-2005, GB4706.232007 and GB 4706.27-2008.
please leave instructions for the
consumer
!
!
!
!
,
-
GB 4706.1-2005 GB4706.23-2007 GB
4706.27-2008
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
A licensed
electrician should make all electrical connections.
Connect only to
a circuit protected by a typical two-pole circuit breaker.
Disconnect
power before servicing.
!
!
!
!
!
!
!
!
!
!
Tape measure
Level
Screw driver
Connection wire
Wire cutter
Insulation tape
Bushing
Percussion Drill
Pen Knife
Wrench
!
!
!
!
!
!
!
!
!
!
RECOMMENDED TOOLS AND MATERIALSRECOMMENDED TOOLS AND MATERIALS
Kohler reserves the right to change marked dimensions without prior notice.
Unit: mm
:
Reference Value
ROUGHING-IN
300
300
266
285
Junction Box Cover
280
256
200
160
12
28
Ventilation Outlet
Hot Air Outlet
1325978-T01-A

-2-
SPECIFICATIONS
Model
Voltage/Frequency
/
220V~/50Hz 220V~/50Hz
Rated Input Power
2150W 2150W
Heater Power
Fan Power
Dry Clothing Power
Ventilation Power
2125W 2125W
25W 25W
2125W(Hot)/25W(Cool) 2125W( )/25W( )
25W
25W
25W
25W
Air-care Power
Lighting Power
Ventilation Volume
Ventilation Noise
Ingress Protection
8W 8W
2.2m /min
3
2.2m /min
3
43dB 43dB
IPX2 (Bathroom Heater) IPX2 ( )
IPX4 (Remote Control) IPX4 ( )
SIMPLIFIED DIAGRAM OF THE UNIT
Note: Plaster or other ceiling opening dimension: 280 X 285 (mm)
280 X 285 (mm)
+5
0
+5
0
+5
0
+5
0
M6 Screw Rod
M6
6 Washer
6
6 Spring Washer
6
Hanger
M6 Screw Cap
M6
Keel
Body
Clamp
Clamp
Air Exhaust Pipe
BTP4*8 Triangular Self Tapping Screw
BTP4*8
Expansion Pipe
M6 Butterfly Nut
M6
BTP4*8 Self Tapping Screw
BTP4*8
Ventilation Outlet Assy.
Air Outlet Window
K-77316T-C-MZ
K-77316T-C-MZ
1325978-T01-A

-3-
WIRING DIAGRAM
LED POWER
LED
HEATER
THERMOSTAT
THERMAL FUSE
OVER CURRENT FUSE
MOTOR
CAPACITOR
ALL-POLE SWITCH (OPTIONAL)
220V
50Hz
CN4
CN7
CN8
CN5
CN2
CN9
CN13
CN1
CN11
CN12
CN10
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
AIR-CARE MODULE
STEPPER MOTOR
INDICATOR LIGHT
MODULE
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 16A
250V 16A
YELLOW/GREEN
/
RED
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
BLACK
BLACK
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
BROWN
GRAY
PINK
PINK
YELLOW
YELLOW
YELLOW
ORANGE
ORANGE
MAIN CONTROL CIRCUIT BOARD
+
+
+
+
+
+
There's no risk of damage to the insulation of power cord.
Copper cord must be inserted into the pillar terminal hole, and make
sure all the cords under the terminal are inserted into the pillar
terminal completely.
Suggest using a power cord which with specification 60227 IEC 53
Model's powercord Specified in GB/T 5023.5 and with cross section
of 3X1.0mm .
,
GB/T 5023.5 60227 IEC 53 ,
3X1.0mm
2
2
Terminal
Conductor
Insulation
8
(Unit: mm)
(: )
WARNING
Make sure the power cord installed firmly,
otherwise it may catch fire.
Conductor
Earth
Power Cord
8
8
13
10
1325978-T01-A

-4-
PREPARATIONS BEFORE INSTALLATION
A. Preparation before the installation A.
1. Open the hole of outlet window
Make sure that the outlet window s position (it should be
lower than the outlet of the bathroom heater to prevent the
water come back to the bathroom heater from the outlet
window), and open a round hole on the wall.
2. Outlet window installation
Fix the air exhaust pipe to the outlet window on the wall
with the clamp as the preparation of bathroom heater
installation. Seal the pipe and the outlet window with
foaming agent.
1.
(
)
2.
Ceiling
Air Exhaust Pipe
Wall
Inside
Outside
Outlet Window
The situation of outlet window on the
wall outside.
The situation of outlet window on the
wall inside.
Outlet Window
Outlet Window
Hole on the Wall
Hole on the Wall
80mm
80mm
115mm
115mm
B. Take out the bathroom from package. B.
Bathromm Heater
1325978-T01-A