Kohler K-772, K-772-N1 Series Manual

Roughing-In Guide
Bath Whirlpool
K-772
M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page 3 Español, página 4
1019470-1-C ©2006 Kohler Co.
USA: 1-800-4-KOHLER
México: 001-877-680-1310
kohler.com
21" (53.3 cm)
1-7/8" (4.8 cm)
3-1/4" (8.3 cm)
8-7/8" (22.5 cm)
K-772-N1
60" (152.4 cm)
No change in measurements if connected with drain illustrated. (K-7161-AF or K-7161M-AF)
Pump/Control Access 34" (86.4 cm) W x 15" (38.1 cm) H
3/4"
42" (106.7 cm)
(1.9 cm)
20-3/8" (51.8 cm)
2-7/8" (7.3 cm) 3" (7.6 cm)
Product Information
With neck jets K-772-N1 shown Without neck jets K-772-N1 not shown
Required accessories: Jet trim kit K-9696
Fixture*: basin area top area weight Bathing
well
To overflow
* Approximate measurements for comparison only.
Product Pump Heater V A* Neckjets 2 hp 1.5 kW 240 15 w/o
Neckjets * Approximate measurements for comparison only.
42(106.7 cm) x 26(66 cm)
water depth capacity 15(38.1 cm) 70 gal (265 L)
1.5 hp 1.5 kW 240 11
54(137.2 cm) x 32(81.3 cm)
460 lbs (208.7 kg)
1/4" (6 mm)
1-1/2" OD
Required Electrical Service
Dedicated circuit required, protected with a Class A Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB):
Pump/control 208-240 V, 20 A, 50/60 Hz Locate the outlet behind the whirlpool and within 24
(61 cm) of the pump.
Installation Notes
Install this product according to the installation guide. Cast iron whirlpools are extremely heavy, making some drop-in
installations difficult. Splitting the deck/surround is recommended if installing into a deck.
Floor support under whirlpool must provide for a minimum of 1500 lbs (680.4 kg).
Hot water supply should be 70% of capacity or greater. Installations will vary.
Fixture conforms to ASME Standard A112.19.1M. All dimensions are nominal.
Drop-in cut-out 58-1/2(148.6 cm) x 40-1/2(102.9 cm) Included Components: Cutout template K-583 template
1019470-1-C 2 Kohler Co.
Loading...
+ 2 hidden pages