BEFORE YOU BEGINBEFORE YOU BEGIN
·
·
·
·
·
·
·
·
Turn off the water supply. The pluming installation must comply with Water Supply Regulations/Bye-laws, Building Regulations or any particular regulations and practices, specified by the local water company or water undertakers. The installation should be carried out by a plumber. Before installation carefully inspect the new fixture for any signs of damage. This product complies with GB 24977-2010.
please leave instructions for the
consumer.
NEW REACH bathroom cabinet adopts E1 grade wood­based panel of high quality, and with further processing, its harmful emissions will be less than 1.5mg/L.
·
·
·
·
·
·
·
·
-
E1
1.5mg/L
GB 24977-2010
ORDERING INFORMATION
This installation covers the following products in the NEW REACH range:
NEW REACH 660mm Washbasin Cabinet..........K-76664T
NEW REACH 1010mm Washbasin Cabinet........K-76663T
660mm .............................................K-76664T
1010mm ...........................................K-76663T
CHANGSHU KOHLER LTD., SOUTHEAST ECONOMIC DEVELOPMENT ZONE,
CHANGSHU, JIANGSU PROVINCE, CHINA POST CODE 215500
215500
©©Copyright Kohler China Investment Co., Ltd. 2015
2015
SAFETY WARNINGS
Kohler products are precision-engineered and should give continued superior and safe performance, provided:
1. They are installed, commissioned, operated and maintained in accordance with the recommendations given in this Manual.
2. Periodic attention is given, as necessary, to maintain the product in good functional order. Recommended guidelines are given in the section.
Carefully inspect the new fixture for any signs of damage.
When installing Kohler Products, manufacturers guidelines for power tool safety should be followed.
MAINTENANCE
1.
2.
1274633-T01-A
Page 2
-2-
K-76663TK-76664T
Fig.1
1
ROUGHING-IN
UNIT : mm
Reference Value
Kohler reserves the right to change marked dimensions without prior notice.
660
1020
483
483
510
510
Fig.2
2
INSTALLATION
A. Install Washbasin Cabinet
Install the services. Hot (H) and Cold (C) inlets must be connected to the correct inlet pipes. Install the drain in accordance with the manufacturer s instructions. We suggest using P-trap drain. Connect P-trap pipe with washbasin drain.
Make sure a watertight seal exisits on all
washbasin drain connections.
Provide access to the plumbing connections
for future plumbing maintenance.
The hot and cold water supplies must be installed with isolating valves.
Caution!
Caution!
A.
(H) (C)
P
1274633-T01-A
Page 3
-3-
Fig.3
3
UNIT : mm
1.
1. Mark the position of hanged bracket according to dimensions as illustrated, and loosen the suspension hook of washbasin cabinet.
Avoid the cables and pipes inner set when
drilling in the wall.
Different types of bolts are required for different
decoration boards. Please apply suitable bolts and plugs.
CAUTION!
NOTE:
20
20
660
553
510
280
20
20
1020
553
Wall Bracket
Wall Bracket
2.
3.
2. Drill holes for fixing the bracket. Using a level, ensure that the hanged bracket is level.
3. Use suitable plugs and bolts, and fix the hanged bracket on the wall.
Fig.4
4
MAX1
2
1
3
4
1274633-T01-A
Page 4
-4-
4.
5.
4. Hang the washbasin cabinet on the wall, and position the suspension on the hanged bracket.
5. Set the washbasin cabinet onto the wall bracket. Be sure the cabinet adjusted level and the back board of cabinet appressed to the wall by adjusting the screws of wall clips.
8
Fig.5
5
6. Mark the wall through two holes at the corresponding positions as illustrated Fig 5.
7. Dismount the washbasin cabinet and put aside. Drill holes at the marked position.
8. Insert the plugs into the wall.
9. Set the washbasin cabinet onto the brackets. Be sure the
cabinet adjusted level and the back board of cabinet appressed to the wall by adjusting the screws of wall clips.
Caution!
NOTE:
Avoid the cables and pipes inner set when
drilling in the wall.
Different types of bolts are required for different
decoration boards. Please apply suitable bolts and plugs.
6. 5
7.
8.
9.
1274633-T01-A
Page 5
-5-
1. (P )
/
Connect Drainage
1. In-wall drainage (P-Trap) Please install the drain assembly and faucet as shown. Please set the water supply and drainage position according to the suppliers instructions. You can adjust the height of shelf to fit the drain assembly.
Faucet
Supply Lines
Shut-off Valve
Drain Assembly
Back Board
Drawer
Fig.6
6
2. S
2. Floor drainage (S-Trap) Please install the drain assembly and faucet as shown. Please set the water supply and drainage position according to the suppliers instructions. You can adjust the height of shelf to fit the drain assembly.
Faucet
Supply Lines
Shut-off Valve
Drain Assembly
Back Board
Ripple Pipe
Outlet
Fig.7
7
Drawer
1274633-T01-A
Page 6
-6-
1.
2.
3.
4.
5.
6.
7.
USER MAINTENANCEUSER MAINTENANCE
Warning! Risk of product damage.
1.
2.
3.
4.
5.
6. Please do not sit, lean or step on the basin cabinet.
7. If any fixtures caused by abnormal reasons, Kohler China can supply paid replacement for service parts caused by abnormal reasons as shown in the Service Parts Page in the limited duration of warranty.
Many cleansers contain abrasive and chemical substance which is not suitable for cleaning stainless steel, enamel, plating or plastic products. You may use mild cleansers or soaps to clean the surfaces. Wipe any splashes of cleaner solutions from the surface with clean soft cloth.
Maintain ventilation in the bathroom, and separate the dry area from the damp one if conditions permit. Try to open the door and windows of the bathroom and maintain good ventilation.
Kohler bathroom cabinet are dealt with strict procedures for damp-proof, whose good damp-proof function ensures good performance even in bathroom of huge humidity. Yet do not splash and pour water directly on the bathroom cabinet. Make sure that the bathroom is not over damp and wipe any splashes from surfaces immediately.
Maintenance of door board: Clean and wipe door board regularly, and wipe the condensation vapor with dry and soft cloth.
Ensure that electrical connections for appliances such as head lamp is insulated wipe mirror surface with chamois regularly to guarantee the persistent excellent performance.