Kodak CP-48S User Manual

CURRENT INFORMATION SUMMARY March 2009 • CIS-229E
Using the KODAK EKTACOLOR Processing Cartridge 111 with Digital Minilabs (Processes CP-48S and CP-49E)
NOTE: If you are located in the US, Canada, or Latin America, use publication CIS-229.
KODAK EKTACOLOR Processing Cartridge 111 and KODAK Rinse Tablets are designed for use with all FUJI FRONTIER Digital Minilabs and models of NORITSU Digital Minilabs using Process Cycles CP-48S and C-49E. The EKTACOLOR Processing Cartridge 111 is a drop-in cartridge for paper processing chemicals.
The cartridge and tablets are part of Kodak’s systems approach that enables users of other manufacturers’ minilabs to provide customers with photographs printed on KODAK Paper and processed in KODAK Chemicals. When used with KODAK EKTACOLOR ROYAL or EDGE GENERATIONS Papers, the processing cartridge will produce prints with rich, bright colors and excellent shadow detail.
The KODAK EKTACOLOR Processing Cartridge 111 is compatible with both FUJI and NORITSU Minilab Systems using Processes CP-48S and CP-49E. There are different time and temperature recommendations for these process cycles. See Figures 1, 2, and 3 for details.
OBTAINING CHEMICALS
These products are offered worldwide. Each cartridge processes 111 square metres of paper when the processor is operated at recommended replenishment rates. They are available from your usual supplier of KODAK Products. Catalog numbers are as follows:
KODAK EKTACOLOR Processing Cartridge 111
CAT No. 838 7375, European Regions US, Canada, Latin America
©Eastman Kodak Company, 2009
KODAK Rinse Tablets
CAT No. 119 9033, European Region CAT No. 191 3110, US/Canada/Latin America Regions
CONVERTING TO THE KODAK EKTACOLOR PROCESSING CARTRIDGE 111
To convert to the KODAK EKTACOLOR Processing Cartridge 111, simply load the cartridge, and let it mix as usual on top of existing solutions. Use KODAK Rinse Tablets in the same way as FUJI FSC100 Super Conditioner Tablets. If you are converting from a FUJI CP-48S, CP-48HV, or CP-49E Processing Cartridge that processes 111 square metres of paper, then no processor adjustments are required to use the EKTACOLOR Processing Cartridge 111. Use the same replenisher and other software settings as for your previous chemical cartridge. However, if you are converting from a FUJI
CP-48LR, or CP-49ELR Processing Cartridge, you will need to adjust the replenishment rates for the Developer Replenisher and Bleach-Fix Replenisher to the rates listed in the following illustrations (Figures 1, 2, and 3).
At the time of the conversion from other chemicals to the KODAK EKTACOLOR Processing Cartridge 111, you may encounter process control biases using KODAK Control Strips and the aims described on page 7. For example, the LD may be low by as much as –0.10.
Figure 1
This bias is explained by slight differences in the formulations of the previous product and the EKTACOLOR Processing Cartridge 111. As the KODAK Chemicals and Paper season into the processor, the low plots will recover closer to the aim values. The printer will calibrate to follow the process shift, and there will be no impact on the picture quality. Depending on the rate of chemical use, it may take several weeks for the full impact of the shift.
For smaller models of FUJI and NORITSU Digital Minilabs, such as the FRONTIER 330 or the NORITSU 3501/3502F, it will take approximately 6 cartridges to fully season the tank solutions with KODAK Chemicals and Paper. For models with larger tank sizes, such as FRONTIER 390 Digital Minilab, it may take up to 30 cartridges to fully season these..
When your processor needs a new cartridge, simply mount the EKTACOLOR Processing Cartridge 111 on the machine, and let it mix as usual. Use KODAK Rinse Tablets in the same way as FUJI FSC100 Super Conditioner Tablets.
FUJI FRONTIER 330,350,355,
Process Cycle with KODAK EKTACOLOR
370, 395, and 390
Processing Cartridge 111
CP-48S
Replenishment Rate
mL/m
2
Time (sec)
Temperature
C ( F)
2
Using the KODAK EKTACOLOR Processing Cartridge 111 With Digital Minilabs, CP-48S/CP-49E CIS-229E
Processing Cartridge 111
Developer
Concentrate
DeveloperP1Bleach-Fix
38.5 +/- 0.3
(101.3 +/- 0.5)
1.
2.
Bleach-Fix
Concentrate
Par t A
45
0:45 0:45
The P2 bleach-fix and PS-1 super rinse overflows can be combined and desilvered together.
Typical is 50 - 60 C (122 - 140 F).
35 (Combined)
38.0 +/- 2.0
(100.0 +/- 2.0)
Bleach-Fix
Concentrate
P2
Par t B
Super Rinse
PS1
Super Rinse
PS2
1:30 Combined Time
All Super Rinse Tanks
35-95 (96 - 104)
Super Rinse
PS3
KODAK Rinse
Tablets
& Water
175 (121 w/RC-50)
Super Rinse
PS4
Dry
2.
Figure 2
FRONTIER 340, NORITSU 3701/02/03/04F
CP-49E
Replenishment Rate
mL/m
2
Time (sec)
Temperature
C ( F)
Follow the manufacturer’s recommendation for the time in a specific model of Digital Minilab.
Processing Cartridge 111
Developer
Concentrate
DeveloperP1Bleach-Fix
42 +/- 0.3
(113.0 +/- 0.5)
1.
2.
Bleach-Fix
Concentrate
Par t A
45
22-27 22-27 21-45 total
The P2 bleach-fix and PS-1 super rinse overflows can be combined and desilvered together.
Typical is 50 - 60 C (122 - 140 F).
35 (Combined)
40.0 +/- 2.0
(104.0 +/- 3.0)
Concentrate
P2
Bleach-Fix
Par t B
Super Rinse
PS1
Process Cycle with KODAK EKTACOLOR Processing Cartridge
KODAK Rinse
Tablets
& Water
215
Super Rinse
PS2
35-95 (101 - 107)
Super
Rinse
PS3
Super Rinse
PS4
Dry
2.
Using the KODAK EKTACOLOR Processing Cartridge 111 with Digital Minilabs, CP-48S/CP-49E CIS-229E
3
Figure 3
FRONTIER 500,550,570,590 and NORITSU QSS 3501/02F & 3705F
CP-49E
Processing Cartridge 111
Replenishment Rate
Temperature
mL/m
Time (sec)
C ( F)
2
Developer
Concentrate
DeveloperP1Bleach-Fix
43.0 +/- 0.3
(109.4 +/- 0.5)
Bleach-Fix
Concentrate
Par t A
45
19-22 19-27 17 - 32
35 (Combined)
43.0 +/- 0.2
(109.4 +/- 3.0)
Concentrate
P2
Bleach-Fix
Par t B
Super Rinse
PS1
Process Cycle with KODAK EKTACOLOR Processing Cartridge
KODAK Rinse
Tablets
& Water
175
Super Rinse
PS2
43-46 (109 - 115)
Super Rinse
PS3
Super Rinse
PS4
Dry
2.
1.
The P2 bleach-fix and PS-1 super rinse overflows can be combined and desilvered together.
2.
Typical is 50 - 60 C (122 - 140 F).
Follow the manufacturer’s recommendation for the time in a specific model of Digital Minilab.
4
Using the KODAK EKTACOLOR Processing Cartridge 111 With Digital Minilabs, CP-48S/CP-49E CIS-229E
Loading...