Up to 16 sub units can be connected to
each main unit.
1) Remove the expansion protective cover
from the main unit.
FS-V22/22G/22R(P)/22X
Instruction Manual
1. Safety Precautions
WARNING
• This product is used to detect targets. Do not apply the product to
safety circuits for human protection.
• This product is not of explosion-proof construction. Do not use the
products in places with flammable gas, liquid, or dust.
• This product is a sensor of DC power supply type. Do not apply AC
power. The product may explode or burn if 100 VAC or a higher voltage is applied.
Check that all the accessories are ready before use.
• Accessories
InstructionEnd units (x2)Expansion Sticker (x1)
manual (x1)
Slide the unit to the
right to remove it.
2) Mount each amplifier to the DIN rail.
3) Press the two claws of each sub unit
to the grooves on the main unit until
the claws snap.
4) Mount the end units to the left- and
right-hand sides of the whole amplifiers in the method shown in the figure
at step 2.
5) Check that the amplifiers are securely sandwiched by the end units. Use a Phillips screwdriver and securely tighten the screws on the
end units (i.e., two screws on each end unit).
4. Connecting Fiber Unit
1) Open the dust cover in the direction
shown by arrow ➀.
2) Move down the fiber lock lever in the
direction shown by arrow ➁.
3) Insert a fiber unit into the fiber insertion holes to a length of the fiber insertion sign (i.e., approximately 14
mm).
Fiber insertion sign
Note:If a thin fiber unit is used, an adapter provided with the thin fiber unit
will be required.
Unless the right adapter is connected, the thin fiber unit will not
detect targets correctly.
Cable outer dia.AdapterAppearance
ø1.3Adapter A
ø1.0Adapter B
• To connect the coaxial reflective type fiber unit to the amplifier, connect
the single-core fiber to the transmitter side, and connect the multiplecore fiber to the receiver side.
4) Move up and return the fiber lock lever
in the direction shown by arrow ➃.
2. Part Names
* The operation indicator of the FS-V22X (infrared model) will not be lit.
Fiber lock lever
Operation indicator*
Set button
Digital
Preset value (PV)
green indicator
monitor
Manual
button
Current value
(CV) red indicator
Expansion protective cover
Expansion connector
Mode button
Output selector
Cable
Dust cover
Single-core fiber
Multi-core fiber
Transmitter
Receiver
• To remove the amplifiers added, take the steps opposite to the mounting procedure.
• Put the provided sticker close to the sensor.
Note • The FS-V22/22G/22R(P)/22X incorporates a mutual interference
prevention function, thus allowing the close mounting of a number
of fiber units in the following modes.
Power mode
Number of
units connected
FINE4TURBO
SUPER
TURBO
8
5. I/O Cricuit
Refer to the following I/O circuit diagram when connecting the unit to peripheral devices.
● FS-V22/22G/22R/22X● FS-V22RP
DC 12 to 24V
Overcurrent
Photoelectric
protection circuit
sensor main circuit
1
ULTRA
TURBO
8
Black
Max. 100mA
Load
(Control output)
8
DC 5 to 40V
Page 2
6. Making Sensitivity Settings
● Full Auto Calibration
In this mode, the PV will be set to the mean value of the maximum and
minimum incident values obtained within a certain period.
Use this mode to detect moving workpieces.
1) Press the set button for a minimum of three seconds while the target
workpiece is passing the sensing area of the fiber unit.
• While the set button is pressed, the sensitivity of the sensor will
be set according to the incident values.
Workpiece
3 s min.
The display will
flash when the
settings are
completed.
• When the setting is finished, the digital monitor will display the PV
in green.
PV (green)
CV (red)
● Two-point Calibration
In this mode, the PV used will be the mean value of two sensing values
obtained with and without a workpiece.
1) Press the set button for a moment without the workpiece in the sensing area (i.e., in front of the fiber unit).
Workpiece
● Manua| Calibration
In this mode, make manual PV settings.
PV
The PV value decreases by pressing
this side of the manual button.
The PV value increases
by pressing this side of
the manual button.
● Positioning Calibration
In this mode, a workpiece will be detected when the front edge of the
workpiece has reached a preset position.
1) Press the set button for a moment without the workpiece in the sensing area (i.e., in front of the fiber unit).
Workpiece
The display will be lit
when the workpiece
is detected.
2) Locate the front edge of the workpiece in the sensing area. Then
press the set button for a minimum of three seconds.
Workpiece
Front edge
3 s min.
The display will flash
for a moment when
the setting is
finished. Then the
PV will be displayed.
The display will be lit
when the workpiece
is detected.
2) Locate the workpiece in the sensing area (i.e., in front of the fiber unit).
Then press the set button for a moment.
Workpiece
The PV will appear when
the settings are completed.
* If there is extremely little difference in sensitivity between the sens-
ing values, the display will flash on completion of tuning.
● Maximum Sensitivity Setting
If the sensing performance of the sensor drops due to dust or dirt, set
the sensitivity of the sensor to maximum.
1) Press the set button without a workpiece if the fiber unit is a reflec-
tive model. Press the set button with a workpiece if the fiber unit is a
through-beam model. In both cases, press the set button for a minimum of three seconds.
“Reflective model”
“Through-beam model”
3 s min.
The display will flash
for a moment when
the setting is finished.
Then the PV will be
displayed.
* If the sensing distance is insufficient, make sensitivity settings in the
sensor in two-point tuning mode.
7. Selecting Output
Either light-ON mode or dark-ON mode is selectable.
Press the mode button.
The display indicates that
the sensor is in dark-ON
mode. The CV will be
Press the manual button
within five seconds after
pressing the mode button .
displayed if no buttons are
operated for approximately
five seconds.
• Take the same steps to set the sensor to light-ON mode again.
8. User-friendly Functions
● Access Mode Selection
Two modes are available to the display of values and menu items.
EASYOnly basic functions are displayed.
FULLAll available functions are displayed.
Press 3 s min.
Completion
of selection
Press 3 s min.
• The mode is set to EASY before shipping.
Select
EASY
FULL
2
Page 3
● Display Selection (Access Mode: EASY)
PVCV
Press
Excess
•The CV is displayed in
CV
gain
percent based on the
PV.
Press
Output
status
•
The current value will be
displayed if no keys are operated
for approximately 30 s.
•
If the timer function is set, the
output status with power mode
and the timer mode with set time
will be displayed alternately.
● Display Selection (Access Mode: FULL)
PVCV
Press
Press
Press
Power
mode status
● Menu Selection (Access Mode: FULL)
Access
mode
selection
Power
mode
selection
Timer
function
setting
Press the
mode button 3 s min
Press
Select
Press
Select
Press
Other than
FINE
TURBO
SUPER TURBO
ULTRA TURBO
HIGH SPEED
HIGH RESO-
LUTION
Normal operation use
Used if the sensing distance is insufficient
while the sensor is in fine mode.
Used if the sensing environment is
bad due to dust or other obstacles.
Used if the incident is insufficient while
the sensor is in SUPER TURBO mode.
Used to detect sensing objects
moving at high speed.
Used to detect delicate differences
within a short sensing distance.
Timer OFF (for normal operation use)
OFF-delay timer
ON-delay timer
One-shot timer
OFF (for normal operation use)
Used to detect sensing objects highly
precisely under clean environments.
OFF (for normal operation use)
Rising edge
Falling edge
OFF (for normal operation use)
ECO half
ECO all
OFF (for normal operation use)
Shift ON
Other than
Press to manual button to
Press
Note: • Press the mode button ( ) for a minimum of three seconds to return to the display of the CV from any menu selection stage. To return to the previous
display, press the mode button (
• When the power mode is set to HIGH RESOLUTION, the S-APC mode will be always turned ON.
• When the power mode is set to HIGH SPEED, the S-APC mode will be always turned ON in the case of the R model, or otherwise the S-APC mode will be
always turned OFF.
make timer adjustments
* For timer values, refer to the
corresponding table under FULL
mode.
) first, and press the left side () of the manual button ().
Sensitivity Settings in Edge Detection Mode
The sensitivity of the sensor will be set to maximum by pressing the
while the sensor is in edge detection mode. Make fine sensitivity adjustments by pressing the .
3
Page 4
9. Key Lock
The key lock function disables the operation of all keys.
Press the manual button for
three seconds while pressing
the mode button.
13. List of Digital Display Items
Preset value/Current value display
Output selection (Dark ON)
Timer function setting (OFF-delay timer)
Timer function setting (ON-delay timer)
Indicates that the
keys are locked.
• Take the same step to unlock the keys.
10. Mode Settings before Shipping (Initialization)
The following factory settings are made before shipping.
Access mode
Power mode
Timer function
Output selection
EASY
FINE
OFF
Light-ON
* Returning to factory settings: Press the button for a minimum of
five seconds while pressing the button.
11. Hints On Correct Use
• To extend the cable length, use a cable with at least a 0.3 mm2 crosssection area. Limit the length of cable extension to no more than 100 m.
(To connect several units, contact Keyence for further information.)
• Do not wire the amplifier line along with power lines or high-tension
lines, or otherwise the sensor may malfunction or receive damage due
to noise.
• When using a commercially available switching regulator, ground the
frame ground terminal and ground terminal.
• Do not use the FS series outdoors, or in a place where extraneous light
can enter the light receiving surface directly.
• Due to the individual dispersion of characteristics and the difference in
fiber unit model, the maximum sensing distance or displayed value of
all the units are not the same.
• If the sensor is used in S-APC mode for a long time, the LED indicators
will be imposed with a heavy load. In that case, the sensor will be automatically set to ACC mode where the current consumption of the sensor for light emission will be constant, and “END APC” will be displayed.
The sensor can be continuously used in this case. Replace the sensor,
however, if highly precise detection is required.
12. Specifications
Model
Light source
Response time
Display shift function
Timer function
Control output
Supply voltage
Current consumption
Rating
Ambient
illumination
Ambient
temperature
Relative humidity
Vibration
Shock resistance
Environment resistance
Housing material
Size
Weight
*1. The model is sold only in Japan. Consult your KEYENCE representa-
tive if the model is required outside Japan.
*2. Ambient operating temperature with amplifier expansion
1 to 2 units: -10°C to 55°C
3 to 10 units: -10°C to 50°C
11 to 16 units: -10°C to 45°C
FS-V22*1FS-V22G
Red LEDGreed LED
250µs (FINE)/500µs (TURBO)/1ms (SUPER TURBO)/
4ms (ULTRA TURBO)/500µs (HIGH RESOLUTION)/
50µs (HIGH SPEED)
Max. ±1999 (variable)
Timer OFF, OFF-delay timer, ON-delay timer, and one-shot timer
1 to 500 ms
NPN open collector with 100 mA max at 40 V with a
max, Residual voltage of 1 V.
DC12-24V ±10% with a maximum ripple (peak to peak) of 10%
35% to 85% RH (No condensation)
10 to 55 Hz, 1.5-mm double amplitude,
each in X, Y, and Z directions for two hours
2
500 m/s
Three times each in X, Y, and Z directions
Unit and cover are both polycarbonate made
W 9 mm x L70 mm x H 30 mm
Approximately 80 g (including 2-m Cable)
FS-V22R(P)
4-element red LED Infrared (950 nm)
S-APC
S-APC mode turned ON or when
mode OFF
the HIGH SPEED mode is selected.
580 mW
480 mW
430 mW
650 mW
530 mW
480 mW
720 mW
600 mW
550 mW
720 mW
600 mW
550 mW
FS-V22X
Output selection (Light-ON)
Access mode selection (EASY)
Access mode selection (FULL)
Excess gain display
LED bar display
Hold display
Power mode selection (FINE)
Power mode selection (TURBO)
Power mode selection (SUPER TURBO)
Power mode selection (ULTRA TURBO)
Power mode selection (HIGH SPEED)
Power mode selection (HIGH RESOLUTION)
Timer function setting (Timer OFF)
Forecast maintenance warning (END APC)
Timer function setting (One-shot timer)
S-APC mode setting (S-APC OFF)
S-APC mode setting (S-APC ON)
Edge detection mode (OFF)
Edge detection mode (Rising edge)
Edge detection mode (Falling edge)
ECO mode setting (ECO mode OFF)
ECO mode setting (ECO half)
ECO mode setting (ECO all)
Shift function setting (Shift OFF)
Shift function setting (Shift ON)
Key lock setting
Key unlock
WARRANTIES (MUST ACCOMPANY THE PRODUCTS): KEYENCE, at its sole
option, will refund, repair or replace at no charge any defective Products within
1year from the date of shipment. Unless stated otherwise herein, the Products
should not be used internally in humans, for human transportation, as safety
devices or fail-safe systems. EXCEPT FOR THE FOREGOING, ALL EXPRESS,
IMPLIED, AND STATUTORY WARRANTIES, INCLUDING WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
KEYENCE SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES RESULT FROM
THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY SUGGESTIONS OR
INFORMATION PROVIDED BY KEYENCE. In some jurisdictions, some of the
foregoing warranty disclaimers or damage limitations may not apply.
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku,
Osaka, 533-8555, Japan
PHONE: +81-6-6379-2211 FAX: +81-6-6379-2131
AFFILIATED COMPANIES
KEYENCE CORPORATION OF AMERICA
PHONE: 201-930-0100
FAX: 201-930-0099
KEYENCE DEUTSCHLAND GmbH
PHONE: 06102-36 89-0
FAX: 06102-36 89-100
KEYENCE (UK) LIMITED
PHONE: 01908-696900
FAX: 01908-696777
KEYENCE FRANCE S.A.
PHONE: 01 47 92 76 76
FAX: 01 47 92 76 77
KEYENCE SINGAPORE PTE LTD.
PHONE: 6392-1011 FAX: 6392-5055
KEYENCE (MALAYSIA) SDN BHD
PHONE: 03-252-2211
FAX: 03-252-2131
KEYENCE (THAILAND) CO., LTD.
PHONE: 02-369-2777
FAX: 02-369-2775
KEYENCE TAIWAN CO., LTD.
PHONE: 02-2627-3100
FAX: 02-2798-8925
KEYENCE (HONG KONG) CO., LTD.
PHONE: 3104-1010 FAX: 3104-1080
KEYENCE INTERNATIONAL TRADING
(SHANGHAI) CO., LTD.
PHONE: 021-68757500
FAX: 021-68757550
KEYENCE KOREA CORPORATION
PHONE: 02-563-1270
FAX: 02-563-1271
Printed in Japan
4