Introduction
This manual contains information about procedures for handling, operations, warnings, and precautions about “Hand-held Barcode Reader HR-51 Series”.
Make sure to read this manual before use. Keep this manual in a safe place for future reference.
■ Symbols
This manual uses the following symbols that alert you to important messages.
Be sure to read these messages carefully.
DANGER
WARNI NG
CAUTION
Note
Indicates reference pages in this manual or other manuals.
Failure to follow instructions and mishandling the product may lead to death or
serious injury.
Failure to follow instructions may lead to physical injury (i.e., electric shock,
burns, etc.).
Failure to follow instructions may lead to the product malfunctions.
Provides additional information on proper operations that can be easily mistaken.
■ General Precautions
• At startup and during operation, be sure to monitor the functions and performance of
HR-51 and confirm the normal operation.
• We recommend that you take substantial safety measures to avoid any damage in the
event the HR-51 series malfunctions.
• If the product is modified or used in any way other than described in the specifications,
its functions and performance cannot be guaranteed.
• When the HR-51 series is used in combination with other devices, the functions and performance may be degraded, depending on the operating conditions, surrounding environment, etc..
• Do not use the HR-51 series for the purpose of protecting the human body.
■ Notice
When this product is used under the circumstances and operating environments
described below, adhere to the limitations of the ratings, take adequate measures to
ensure safety such as fail-safe installations and consult a KEYENCE sales representative.
• For use under circumstances or environments which are not described in the manual.
• For use with nuclear power control, railway, aircraft, vehicles, incinerators, medical
equipment, entertainment equipment, safety devices, etc.
• For use in applications where death or serious property damage is possible and extensive safety precautions are required.
Page 3
Safety Precautions
■ Safety Precautions on Laser Apparatus
WARNING
Use of controls or adjustments or performunce of procedures other than those
specified herein may result in hazardous radiation exposure.
The “Hand-held Barcode Reader HR-51 Series” employs a visible red semiconductor laser
for its light source. HR-51 has a wavelength of 650 nm and is classified as a Class 2 laser
under IEC standard (IEC60825-1: “Safety of Laser Products”).
ModelHR-51
Wavelength650nm
Maximum output1.0mW
ClassCLASS 2 (IEC60825-1)
• Do not directly stare into the laser beams or specularly reflected light. Doing
so may result in serious eye injury. Do not direct laser beams towards a human
body intentionally although laser beams will not cause damage even if it
strikes exposed skin.
• Never disassemble HR-51. HR-51 is not equipped with a mechanism to stop
laser emission when disassembled. If HR-51 is disassembled, laser beams
WARNING
emitted from HR-51 may cause eye injury.
• Before cleaning the transmitter/receiver part of laser scanner, be sure to stop
the emission of laser beams. Otherwise, exposure to the laser may cause eye
injury.
• Be careful of the light path of laser beams.
Be especially careful of the specularly reflected light.
Do not install HR-51 in such a way that the laser beam passes at eye height
when operating HR-51.
■ Warning label locations
HR-51
1
Page 4
Operating Precautions
■ Precautions on use
• Do not disassemble or modify this unit. Doing so may lead to product fail-
ure.
• This unit is a precision instrument. Dropping the unit or subjecting it to
shock may cause damage. Take enough care when carrying or using this
unit.
• Locate cables as far as possible from high-voltage lines and power lines.
Otherwise, generated noise may cause product failure or operation error.
• Do not hold the unit by its cable when carrying. The HR-51 may strike the
wall and may be damaged. Also due to the stress on the cables, the wires
may be broken.
• Be sure to use the supplied AC adaptor or optional AC adaptor for HR-
UC51. Using other AC adaptors than these may result in fire, electric shock
or product failures.
• Be sure to periodically clean the power connection part of AC adaptor con-
nected to HR-UC51 as it tends to catch dust. Tracking phenomenon may
result in fire. Also, disconnect the AC adaptor from the outlet if not using a
long period of time.
CAUTION
• When recharging HR-51 on HR-UC51, be sure to check no foreign objects
are attached to the recharge terminal. Foreign objects may cause fire.
■ Environments for use
Do not use in the following locations. Product failure or mechanical error may
occur.
• Locations where the ambient temperature is beyond specified range
• Locations where the ambient humidity is beyond specified range
• Locations where the unit is exposed to direct sunlight
• High-temperature locations such as inside a closed car
• Locations where condensation occurs due to the rapid humidity change
• Locations where there are corrosive gas or combustible gas
• Locations where there is a large amount of airborne dust, salt, iron, and
greasy fumes
• Locations where the unit may be directly subjected to vibration or impact
• Locations where water, oil or chemicals may splash onto the unit
• Locations where a strong magnetic or electric field is generated
2
Page 5
Precautions for using the built-in rechargeable battery
HR-51 contains the built-in lithium ion rechargeable battery. Observe the following precautions for proper use.
On disposal, follow the disposal procedure specified by each local government.
•
Stop the recharging process if recharging does not finish even after the specified recharge time.
The built-in rechargeable battery may become hot, explode or cause fire.
• If there is leak or abnormal smell from the built-in rechargeable battery, keep it
DANGER
WARNING
CAUTION
away from fire immediately.
The battery electrolyte may catch fire, resulting in explosion and ignition.
• Never put it into the fire. The explosion of built-in rechargeable battery may
lead to a serious accident.
• Never put it into the water. The chemical reaction of the built-in rechargeable
battery may lead to an accident.
• In the event that the leaked liquid comes into the eye, do not wipe it. Clean it
immediately with clean water instead and go to the eye specialist. If the eye is
left untreated, eye damage may result.
• In the event the liquid leaked from the built-in rechargeable battery is attached
to the skin, wash it immediately with clean water. Otherwise, skin irritation may
occur.
•
Do not leave or use it in a heated car, under the scorching sun or at highhumidity locations. The built-in rechargeable battery may become hot or cause
fire. Also, the battery life may become short and the performance may deteriorate.
• Recharge and use the built-in battery in the temperature environment of –5 to
140 degree. If it is used in other temperature environments than this, the builtin rechargeable battery may be hot or damaged. Also, the life become short
and the performance may deteriorate.
• Never use other rechargers than the specified one. Product failure may occur.
3
Page 6
Wireless communication
HR-51 and HR-UC51 contain the built-in wireless device based on the Bluetooth wireless
technology.
Never disassemble or modify HR-51 and HR-UC51 as those conducts are pro-
CAUTION
■ Cautions for wireless communication
• If the product is used near a wireless LAN device with the same frequency band as that
of HR-51 and HR-UC51, radio wave interference may occur and the communication
speed becomes slow or communication may become impossible.
• The communication may be impossible near equipment using the same frequency band
of electric wave as that of HR-51 and HR-UC51, such as microwave oven, industrial
heating equipment and medical high-frequency equipment.
• Communication may be impossible in the following locations
- Locations near metallic objects or where there is much metallic powder
- Locations surrounded by a metallic wall
- Locations where the unit is subject to strong vibration
• Communication-possible distance is approx. 10 m, however, depending on the environment for use, communication may be impossible. Make sure to check the communication condition before introduction.
• With the frequency band for HR-51 and HR-UC51, premise radio stations (with license
required) and specified low power radio station (with license not required) for identifying
mobile objects used for industrial, scientific and medical equipment or product lines in
factory are operating.
• Before using HR-51 and HR-UC51, be sure to check that premise radio stations and
specified low power radio stations are not operating in the vicinity.
• If radio wave interference occurs from HR-51 and HR-UC51 against premise radio stations for identifying mobile objects, stop the electric wave generation, contact the following address and consult to take necessary measures (i.e. setting a partition) to avoid
interference.
• If radio wave interference occur from HR-51 and HR-UC51 against specified low power
radio stations for identifying mobile objects or other problems occur, contact the following address.
hibited by the Radio Law. HR-51 and HR-UC51 are regarded as specified low
power radio devices and they obtained Construction Design Certification
according to the standard required by law.
1
2.4 : This represents wireless equipment using
2.4GHz band.
FH: This represents the modulation method of
FH-SS.
1: This represents the assumed interference
distance (≤ 10m)
: This represents the whole band is used and
the equipment range for identifying mobile
objects is unavoidable.
4
Page 7
Safety Regulations and Standards
■ FDA regulations
HR-51 Series complies with FDA laser product regulation and is classified as class 2 laser
product.
Applicable regulation: 21 CFR Part 1040.10, 1040.11
The classification is based on IEC60825-1 following the Laser Notice No. 50 from FDA
(CDRH).
■ FCC regulations
HR-51 Series complies with the following FCC regulations.
Applicable regulation : FCC Part 15 Subpart B, Class B digital devices
FCC Part 15 Subpart C
FCC ID: RF40945A (HR-51)
RF40945B (HR-UC51)
FCC WARNING
Changes or modifications not expressly apprvoed by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with
Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTICE
The HR-51 and the HR-UC51 have been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
The HR-51 and the HR-UC51 generate, use and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If the HR-51 and the HR-UC51 do cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
5
Page 8
The HR-UC51 complied with FCC radiation exposure limits set forth for uncontrolled
equipment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement
C to OET65. The HR-UC51 has very low levels of RF energy that it deemed to comply
without maximum permissive exposure evaluation (MPE). But it is desirable that it should
be installed and operated with at least 20cm and more between the radiator and person’s
body (excluding extremities: hands, wrists, feet and legs).
The HR-51 complies with FCC radiation exposure limits set forth for uncontrolled equipment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to
OET65. The HR-51 has very low levels of RF energy that it is deemed to comply without
testing of specific absorption ratio (SAR).
■ CE Marking
HR-51 Series complies with the requirements of R&TTE Directive.
Applicable standards : ETSI EN300 328
ETSI EN301 489-1
ETSI EN301 489-17
EN60950-1
EN60825-1, Laser Class2
Overvoltage category : I (HR-51)
II (HR-UC51)
Pollution degree2
■ EU Countries where HR-51 Series can be used
HR-51 Series can be used in the following EU countries.
c Austriac Belgiumc Cyprusc Czech
c Denmarkc Estoniac Finlandc France
c Germanyc Greecec Hungaryc Ireland
c Italyc Latviac Lithuaniac Luxemburg
c Maltac Hollandc Portuguesec Slovakia
c Sloveniac Spainc Swedenc United Kingdom
c Polandc Bulgariac Romania
6
Page 9
Maintenance
Clean the following parts of HR-51 and HR-UC51 periodically.
• HR-51
Clean the transmitter/receiver and recharge terminal.
Transmitter/receiver
• HR-UC51
Clean the recharge terminal.
Recharge terminal
Recharge terminal
■ How to clean
Transmitter/receiver : Wipe it lightly with an eyeglass cloth or a soft cloth moistened with a
plastic cleaner.
Recharge terminal : Wipe it lightly with a soft cloth moistened with alcohol.
7
Page 10
MEMO
8
Page 11
Overview
This chapter explains the package contents list, part names and
functions, and basic operations.
HR-51 comes with the following items. Check that all of the items are included.
Hand-held Laser Barcode Reader HR-51
1
■ Main unit: 1
Overview
ModelCommunication interface
HR-51Bluetooth interface
• HR-51• Laser warning seal
• Strap
Japanese/English
German
French
Chinese
■ User’s manual: 1
Wireless
Hand-held Barcode Reader
HR-51 Series
User’s Manual
Read this manual before use in order to achieve maximum
performance.
Keep this manual in a safe place after reading so that you
can use it at any time.
1-2
Page 13
1-1 Checking the Package Contents
Communication unit HR-UC51 (Dedicated use for HR-51)
■ Main unit: 1
ModelCommunication interface
HR-UC51Bluetooth interface
• HR-UC51• BD address barcode label
■ Cables
• RS-232C cable• USB Cable
1
Overview
■ AC adaptor: 1■ Operating instructions: 1
1-3
Page 14
1-1 Checking the Package Contents
Options
■ Stand OP-87027
• OP-87027: Use this stand when placing HR-51 on a table top
1
Overview
■ Stand OP-87026
•
OP-87026
: Use this stand when using HR-51 in detection mode, etc.
■ AC adaptor
• OP-84372: AC100 to 240V applicable (Same as the supplied accessory for HR-UC51)
1-4
Page 15
1-2Part Names and Functions
This section explains the part names and functions
HR-51
HR-51
1
Overview
Operation status LED:
( page 1-7)
Transmitter/receiver:
Emits laser beams and receives
the reflected light.
Trigger switch:
Used when reading barcodes.
Recharge terminal
1-5
Page 16
1-2 Part Names and Functions
HR-UC51
HR-UC51: front
1
Reader search button:
Overview
Checks the connection of
HR-51 is established.
The paired HR-51 sounds a
buzzer.
Recharge terminal
bottom
Operation status LED:
( page 1-7)
back
1-6
BD address barcode
Power terminal
USB port
RS-232C port
Page 17
Operation status LED
■ HR-51
LED colorLED light-up timing
Green
Red
Orange
Blue
■ HR-UC51
• When fully charged
• When recognizing barcode in program mode
• When reading the Setup barcode that cannot be set
• When recharging
• When read data cannot be transmitted
• When the remaining battery level is low
• When the connection with HR-UC51 is established
• When the transmission of read data is complete
• When scanning the Setup barcode
1-2 Part Names and Functions
1
Overview
LED
number
➀
➁
➂
LED
color
RedWhen the power is turned on
GreenWhen data transmission is complete
RedWhen data transmission is impossible
Blue
LED light-up timing
Lights up: When the connection with
HR-UC51 is established
Blinks:When the connection is
not yet established
1-7
Page 18
1-3Basic operations
This section explains the basic operations of the barcode reader.
Reading a barcode
1
Point the transmitter/receiver toward the barcode and press the trigger switch about 50 mm
Overview
away from the barcode.
• When the barcode is read, the operation status LED (green) lights up and the buzzer
sounds.
(You can make the setting for the operation status LED and the buzzer not to operate.)
• The read barcode data is sent to the connected computer or other equipment.
■ Notes for reading
Adjust the reading direction and reading timing so the laser beam can be emitted from the
one end to the other end of barcode to scan correctly.
• Correct scanning
• Wrong scanning
You cannot specify which barcode to read
1-8
Page 19
Connections
This chapter explains the connection methods for HR-51 Series.
HR-51 and the communication unit HR-UC51 communicate in pairs. Before operation, be
sure to establish the connection (pairing) between HR-51 and the communication unit HRUC51.
•
Note
HR-51 operates in fully-charged condition.
• The communication unit HR-UC51 operates with the power ON.
2
Procedure
Connections
Note
When the connection (pairing) is not established, the following operations or conditions
result.
• After the barcode is read, the operation status LED of HR-51 lights red once and the
buzzer sounds.
• LED ➂ of HR-UC51 blinks blue.
Perform the following operations in this condition.
• Note that even if you use more than 2 units of HR-51, communication is possible only
between connection-established HR-51 and the communication unit HR-UC51.
1Press the “Trigger switch” to emit the laser beams.
2Select the communication interface.
(As a default setting, RS-232C interface has been selected.)
3Read the BD address barcode attached to the communication unit or supplied BD address
barcode.
50mm
2-2
Page 21
2-1 Connecting HR-51 to HR-UC51
When the connection (pairing) is established, the following conditions result.
• After the barcode is read, the operation status LED of HR-51 lights blue once and the
buzzer sounds.
• LED ➂ of HR-UC51 lights blue.
If you change the communication interface, turn OFF and ON once and read the
CAUTION
BD address again. Otherwise, the unit may not operate normally (i.e. connection
failure, transmission failure).
Notes when the wireless connection is established between HR-51 and HR-UC51
■ For reading the barcode
You cannot read the barcode in the establishment process with HR-UC51.
■ When multiple HR-51 and HR-UC 51 are connected
• Only connected pairs can communicate.
• If multiple HR-51 read the same address bar code of HR-UC51, only the first connec-
tion-established HR-51 can communicate with HR-UC51. If you wish to change pairs of
HR-51 and HR-UC51, perform the same operation as described at “Changing pairs of
HR-51 and HR-UC51” below.
■ Changing pairs of HR-51 and HR-UC51
If you change HR-51 in use to another HR-51, perform the following operations.
Procedure
2
Connections
1Cancel the connection of connection-established HR-51 in either way of the following.
• Cut connection by reading the Connection-cut barcode.
• Cut connection by pressing and holding the trigger key.
• Cut connection automatically during wireless communication.
2Read the BD address of HR-UC51 using another HR-51.
Note
If you restart HR-UC51, the connection of HR-UC51 will become unestablished. Make
sure to establish 1 to 1 connection between HR-51 and HR-UC51.
2-3
Page 22
2-2Connecting HR-UC51
After cables are connected, connect the communication unit to equipment with the connection method according to the communication interface.
Connecting to a computer using the USB interface
Connect to the USB port of the computer. Compliant OS: Windows Vista/XP/2000/98
2
HR-UC51
Connections
CAUTION
■ Notes when using the computer
• Do not read a barcode while pressing down a key. Do not enter a key while receiving
data.
• Set the input mode to “half-width alphanumeric characters”.
• You can select keyboard specifications.
Be sure to use the supplied AC adaptor or optional AC adaptor. Using other
power sources may damage the unit.
Installing the USB driver
When HR-UC51 is first connected to a Windows 98 PC, the USB driver installation screen
appears. Install the driver according to the on-screen instructions.
(Windows Vista, XP and 2000 do not require this operation.)
Note
Connect the barcode reader after the startup of the computer. If it is connected with the
power OFF, start the computer.
To computer
USB port
(A type)
Procedure
1The “Add New Hardware Wizard” screen appears and the message “This window
searches for new drivers for: USB human interface device” is displayed. Click “Next”.
2-4
Page 23
2-2 Connecting HR-UC51
2The message “What do you want Windows to do?” is displayed. Then select “Search for
the best driver for your device (Recommended)” and click “Next”.
3Click on the “Next” button. “USB human interface device” is displayed and the message
“Windows driver file search for the device” appears. Click “Next”.
Note
The CD-ROM (Windows) may be required depending on the computer environment.
4Windows begins installing the driver. When installation is complete, the message “Win-
dows has finished installing the software that your new hardware device requires.” appears.
Click “Finish”.
Connecting to a computer using the RS-232C interface
The barcode reader can directly connect to the serial port (RS-232C D-sub9 pin connector)
of a DOSV computer.
HR-UC51
To computer
RS-232C
(D-sub9 pin)
CAUTION
■ HR-UC51 connector pin
54321
9876
D-sub9 pin (female)
#4-40 screw
Be sure to use the supplied AC adaptor or optional AC adaptor. Using other
power sources may damage the unit.
Pin number
1FGFrame Ground–
2SD (TXD)Sends DataOutput
3RD (RXD)Receives DataInput
4DR (DSR)Data set readyInput
5SGSignal Ground–
6–Do not connect.–
7CS (CTS)Can SendInput
8RS (RTS)Requests to send dataOutput
SymbolDescription
Signal direction
2
Connections
Note
DR (DSR) and ER (DTR) functions cannot be used.
2-5
Page 24
2-2 Connecting HR-UC51
■ Communication settings
The default settings for HR-UC51 are as follows. The setting values can be changed.
Make sure that the settings for HR-UC51 and the connected computer are the same.
• Baud rate : 9600bit/s
• Data length : 7 bit
• Parity: Even
• Stop bit: 1 bit
• Communication protocol : Non-procedure
2
■ Connecting to DV-90 Series
Connections
To connect to DV-90 Series, the conversion connecter is necessary as below.
HR-UC51
Use the following conversion connector.
• Manufacturer : ELECOM Inc.
• Product name : Serial Reverse Adaptor
• Model: AD-R9
Conversion Connecter
DV90
RS-232C
(D-sub9 pin)
2-6
CAUTION
•
Be sure to use the supplied AC adaptor or optional AC adaptor. Using other
power sources may result in fire, electric shock or product malfunctions.
• Power is supplied from the AC adaptor. Power is not supplied from the D-sub
connector.
Page 25
2-3Recharging HR-51
Use the dedicated communication unit HR-UC51 to recharge HR-51.
Note
■ Recharge method
There is no remaining battery at the time of shipment. Be sure to charge the battery
when using this product for the first time.
1Connect the supplied AC adaptor or optional AC adaptor to the communication unit HR-
UC51 and confirm the power is ON.
2Set HR-51 to the communication unit HR-UC51 so the recharge terminal of HR-UC51 is
not misaligned with that of HR-51.
As soon as recharging starts, the operation status LED of HR-51 lights red.
Recharging is complete when the operation status LED of HR-51 lights green.
2
Connections
Note
Clean the recharge terminals of HR-51 and HR-UC51 periodically ( page 7).
Dirt will interfere with recharging.
2-7
Page 26
2-3 Recharging HR-51
HR-51 rechargeable battery
If the battery level of HR-51 becomes low, the operation status LED lights orange.
Pay attention to the operation status LED while operating and recharge the battery whenever
necessary.
■ Continuous use time
The following chart shows approximate continuous use time in each case after recharging
HR-51 is complete.
2
Connections
■ Recharge time
Reading 1 time/5 sec.15 hours
Keeping the connection *116 hours
Wireless not connected250 hours
*1 The battery is consumed even when not in use as HR-51 and HR-UC51 always communicates wirelessly.
• It is recommended that HR-51 is set on HR-UC51 when not in use.
•
Note
The following chart shows approximate recharge time from battery level 0 to fully-charged
level.
• If the continuous use time becomes extremely short, replace the battery. Consult
ConditionsApproximate continuous use time
The above continuous use time is approximate and may become shor ter depending
on the period of use.
your nearest dealer.
Recharge methodRecharge time
When power is supplied from the AC adaptorApprox. 3 hours
When power is supplied from the USB bus powerApprox. 6 hours
2-8
Page 27
2-4Checking the connected pairs
Checking the connection pairs may be necessary in the environment that multiple HR-51 and
the communication unit HR-UC51 are used. For example, when you are not sure which communication unit is connection-established with HR-51, use this function.
■ How to check the connected pairs
Press the “Reader search button” of the communication unit HR-UC51 while the connection between HR-51 and HR-UC51 has been established.
Reader search button
2
Connections
The paired HR-51 sounds a buzzer.
2-9
Page 28
2-5Wireless communication environment
Bluetooth Version 1.2 is used for the wireless communication between HR-51 and the communication unit HR-UC51. Use in the following environment.
■ Communication distance and surrounding environment
HR-51 and the communication unit HR-UC51 can communicate wirelessly within the
range of approx. 10 m.
However, the wireless communication is interrupted if obstacles such as concrete and a
2
Connections
metal exist. Use in environments with no obstacles.
Obstacle
Read “Cautions for wireless communication”. ( page 4)
■ Operations when the wireless communication is interrupted
If the communication is cut, the following operations result.
• The operation status LED of HR-51 lights red once and the buzzer sounds.
• The operation status LED ➂ of communication unit HR-UC51 blinks.
When wireless communication becomes available, the setting is automatically restored
according to the setting contents of automatic reconnecting operation.
If connection fails within the automatic reconnecting operation period, make connection
again using either of the methods below.
• Read “Connection-ON barcode”.
• Read the readable barcode when “Automatic connection after reading the barcode”
is “Enable”.
• When “Connection on/cut by pressing down the trigger key” is “Enable”, press down
the trigger key for the set time for “Trigger key pressing-down time: Connection ON”.
• Read the BD address of HR-UC51.
Note
If the BD address of UR-UC51 has not been registered on HR-51, read the BD address
of HR-UC51 before connection.
Built-in batteryLithium ion battery, continuous use time: 16 hours
Wireless frequency
Communication
output
Communication
distance
2402MHz to 2480MHz
CLASS 2 (max. 2.5 m)
Scope 10m
A-2
Page 31
A-1 Specifications
HR-UC51 General specifications (Communication unit dedicated for HR-51)
ModelHR-UC51
Wired
communication
part
Wireless
communication
part
Recharge
part
Environment
resistance
Dimensions78×100×185mm
WeightApprox. 230 g (excluding cables)
AC adaptor specificationsSee OP-84372 specifications.
Communication
standard
Connector shapeUSB (B type)D-sub9 pin (female)
Wireless standardBluetooth Ver2.0
Wireless frequency
Communication
output
Communication
distance
Recharge systemConstant-current and constant-voltage system
Recharge time
Ambient
temperature
Storage ambient
temperature
Ambient humidity25 to 85% RH, No freeze or condensation
Storage ambient
humidity
Operating
atmosphere
USB Ver2.0 (HID class)
compliant
2402MHz to 2480MHz
CLASS 2 (max. 2.5 m)
Scope 10m
AC adaptor: approx. 3 hours
USB bus power: approx. 6 hours
–5 to +40°C
–20 to +60°C
20 to 90% RH, No freeze or condensation
No dust or corrosive gas present
RS-232C compliant
Appendix
A-3
Page 32
A-1 Specifications
■ Interface specifications
USB interface
USB versionUSB-HID Fullspeed
Compliant OSWindows Vista/XP/2000/98
Format of sent dataSame as data sent from keyboard
RS-232C interface
Synchronization methodStart-stop synchronization
Transmission codeASCII code
Baud rate
Data length7/8 bit
Parity checkNone/Even/Odd
Appendix
Stop bit length1/2 bit
Flow controlNon
600, 1200, 2400, 4800, 9600,
19200, 38400, 57600bit/s
A-4
Page 33
A-2Dimensions
■ HR-51(Unit: mm)
56
112.8
25
132
29
■ HR-UC51(Unit: mm)
70
60
83
50
Appendix
100
185
A-5
Page 34
A-2 Dimensions
■ Supplied cables
• RS-232C cable(Unit: mm)
1500
D-SUB9PIN
FEMALE
• USB cable
1500
Appendix
■ AC adaptor
• OP-84372 (supplied with HR-UC51)(Unit: mm)
USB-B connectorUSB-A connector
47
7227
1800
1800
A-6
Page 35
A-2 Dimensions
■ Stand OP-87027
• OP-87027(Unit: mm)
44.5
71
75
85
Appendix
A-7
Page 36
A-2 Dimensions
■ Stand OP-87026
• OP-87026(Unit: mm)
Appendix
64
72
64
134
A-8
295
170
106
146
Page 37
Warranty
1Warranty period
One-year warranty is provided for this product after it is delivered to the designated place.
2Warranty scope
(1) If failure occurs under KEYENCE responsibility during the above warranty period, free repair
service is provided.
However, the following cases are excluded from the warranty scope.
➀ Malfunctions caused by improper conditions, environments, handling and operations
other than those described in the operating instructions, user’s manual and separately
provided specifications.
➁ Malfunctions caused by user’s device or design contents of software except for
KEYENCE products.
➂ Malfunctions caused by modification or service done by other parties than KEYENCE.
➃ Malfunctions that could have been prevented if the consumable parts described in the
operating instructions or user’s manual had been properly maintained and replaced.
➄ Malfunctions that were not foreseeable with the technology at the time of shipment.
➅ Malfunctions caused by other external factors irrelevant to KEYENCE (i.e., fire, earth-
quake, flood, etc.)
The limit of warranty period is as described above (1). KEYENCE will not responsible for secondary
damages (device damage, opportunity loss, lost earnings, etc.) and any other damages on user’s
side resulted from malfunctions of KEYENCE products.
3Applicable scope of product
KEYENCE products are designed and manufactured as general-purpose products for general
industrial use.
The following uses are not intended and are out of applicable scope.
However, if a user consults KEYENCE beforehand, confirms the product specifications under the
userfs responsibility, approves the rating and performance, and then take necessary safety measures, the use is applicable.
Even in this case, the warranty scope is the same as described above.
➀ For use with facilities where death or serious property damage are possible, such as
nuclear power generation, aircraft, railway, ship, vehicles, medical equipment, etc.
➁ For use with public facilities such as electricity, gas, water, etc.
➂ For use outdoors and in similar conditions and environments
Page 38
KEYENCE CORPORATION OF AMERICA
50 Tice Blvd., Woodcliff Lake, NJ 07677 PHONE: 1-201-930-0100
Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved. Printed in Japan
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.