CH2 : Mecha digital (DXM-680x : 4V , Other : 5V)
IC80Switching RegulatorPower supply for VFD. (57V)
IC100Reset IC“L” when detection voltage goes below 3.6V or less.
IC102System µ-com
IC103Muting logic ICControls logic for muting.
IC104EEPROMFor instraller’s memory
IC200Power Control ICPower control switch
IC300Eelectrical Volume & Source SelecterControls the source, volume, and tone.
Controls FM/AM tuner, the changer, CD/MD mechanism,
Panel, volume and tone.
Panel mecha control
IN1IN2Panel mecha
IC450Panel mecha motor driver
IC451G-AnalyzerAnalog gravity sensor.
IC600±9V AVRPower supply for 5V Pre Out OP-AMP.
IC601~603 5V Pre-out AMPOutput buffer and gain control.
IC750Power ICAmplifies the front L/R and the rear L/R to 50W maximum.
Q80,81VFD (57V) AVR SWWhen Q81’ base goes Hi, VFD (57V) AVR outputs 57V.
Q91Panel5V Discharge SWWhen Q91’ base goes Hi, Panel5V is discharged.
Q100,101Panel Detect SWWhen Q100’ base goes Lo, panel is detected.
Q200,201Pre-out mute driverWhen a base gose Lo, mute driver is turned on.
Q202Acc Detect SWWhen Q202’ base gose Hi, Acc voltage is detected.
Q204Surge Detect SWWhen Q204’ base goes Hi, IC750 is changed into a standby state.
Q205B.U Detected SWWhen Q35’ base gose Hi, B.U voltage is detected.
Q207Small-lamp Detect SWWhen Q207’ base goes Hi, Small-lamp is detected.
Q208,209Power Antenna SWWhen Q206’ base goes Hi, power antenna switch outputs 14V.
Q300DSP mute SWWhen base goes Lo, DSP is set to mute.
Q402,403AM+B SWWhen Q403’ base gose Hi, AM+B is outputs.
Q450DSI DriverDSI turns off when the base is “H”.
Q600~602Pre-Amp +9V AVR
Q603~605Pre-Amp -9V AVR
Q606,607AUDIO 10.5V AVRWhen Q606’ base goes Hi, AVR outputs 10.5V.
Q608~613Pre-out mute SWWhen a base gose Hi, Pre-out is set to mute.
Q800,802REF+B AVRWhen Q800’ base goes Hi, AVR outputs 13V.
Q801SVR6.8V Ref Supply AGC Controller
This FET is governed by IC60.
Frequency is decided at Q61.
This FET is governed by IC60.
Frequency is fixed 400kHz.
DSI lights when the base is “L”.
DSI turns on and off when panel is taken off.
Q600 and 602 works as a differential amplifier,
Q601 works as a driver and +9.4V is supplied to OP Amp for Pre-out.
Q603 and 605 works as a differential amplifier,
Q604 works as a driver and -9.1V is supplied to OP Amp for Pre-out.
When the voltage of B.U voltage falls, a return is hung and an output
is reduced.
IC4PANEL µ-COM
IC5RESET ICWhen panel is attached, IC5 active
IC6REMOTE CONTROL ICRemote control receiver
IC7BUFFER ICIt is change into 3.3V from 5V
IC8BUFFER ICIt is change into 5V from 3.3V
IC9BUFFER ICFor Control ED1
IC102.5V REGULATORThe power supply For 2.5V
IC113.3V REGULATORThe power supply For 3.3V
Q1
ROM IC
FLASH ROM IC
TRIANGLE GREEN
LED SW
Graphics data included
Triangle green LED is lighting when Q1’s base level goes “H”
Q3BLUE LED SWBlue LED are lighting when Q3’s base level goes “H”
Q4GREEN LED SWGreen LED are lighting when Q4’s base level goes “H”
Q5RED LED SWRed LED are lighting when Q5’s base level goes “H”
Q6SW3.3V SW
Q7,8SW5V SW
Q9,10FL3.3V SWFL+3.3V (VDD1) is turned on when Q9’s base level goes “H”
Q12FL BLK SWED1 is lighted on when Q7’s base level goes “H”
Q11,13FL+B SWFL+B (VDD2) is turned on when Q11’s base level goes “H”
IC1A3.3V regulatorPower supply for audio 3.3V
IC2Ope amp for low-pass filter
IC34ch BTL driverDriving spindle motor and loading/ejection operation
IC4Mechanism µ-com
IC5BU 3.3V regulatorPower supply for backup 3.3V
IC6D3.3V regulatorDigital 3.3V power supply
IC7Audio DAC built-in servo DSPMP3, WMA, and AAC compatible
IC11Buffer ICLevel shift
Q1A3.3V discharge circuit
Q4Current ampAdjusts current to be sent to laser
Q5,6SW 5V
Q7,8SW 8V
D1For current amp
TRIANGLE RED
LED SW
Triangle red LED is lighting when Q2’s base level goes “H”
SW3.3V the power supply of IC1, 3 is turned on when Q6’s base
level goes “L”
SW5V the power supply of IC2, 6 is turned on when Q8’s base
level goes “H”
5
KDC-MP732
MICROCOMPUTER’S TERMINAL DESCRIPTION
● SYSTEM MICROCOMPUTER : 30625MGPA78GP (X34 : IC102)
Pin No.Pin NameI/OFunctionProcessing Operation
1VREF-Analog reference voltage
2AVCC3LX DATA SIData from slave unit
4LX DATA MOData to slave unit
5LX CLKI/OLX-BUS clock
6WIRED REMOIExternal display remoter controller
7LX MUTEIMute request from slave unitH : MUTE ON, L : MUTE OFF
8AUD SDAOE-VOL dataSPI communication
9AUD SELOE-VOL controlSPI communication
10AUD SCLOE-VOL clockSPI communication
10DSP_SCLODSP clock output terminalSPI communication
11DAC RSTODAC resetL : DAC RESET
11NCONot usedL-output for models without DSP
12NC-Not used
13BYTE-GND
14CNVSS15XCINIClock32,768kHz
16XCOUTIClock32,768kHz
17RESETIReset
18XOUT-Clock12MHz
19VSS-GND
20XIN-Clock12MHz
21VCC122NMIINot used
23PANEL DETIPanel detectionH : No panel, L : Panel exists
24RDS CLKIRDS decoder clock
24NCONot usedL-output for models without RDS/RBDS
25LX REQ SICommunication request from slave unit
26PON AMI/OAM power supply controlAM in operation : H, AM not in operation : HI-Z
27LX REQ MOCommunication request to slave unit
28TUN IFC OUTIFront-end IFC outH : Station exists, L : No station
29NCONot used
30RDS AFS MI/OTime constant switching when noise detectedRefer to Truth Value Table r
30NCONot usedL-output for models without RDS/RBDS
31RDS QUALIRDS decoder QUAL
31NCONot usedL-output for models without RDS/RBDS
32RDS DATAIRDS decoder DATA
32NCONot usedL-output for models without RDS/RBDS
33PWIC BEEPOBeep
34TUN SCLI/OFront-end I2C clock
35TUN SDAI/OFront-end I2C data
36SYS DATAOInside-panel communication dataMAX 500kbps
6
KDC-MP732
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No.Pin NameI/OFunctionProcessing Operation
37VCC138PAN DATAIInside-panel communication dataMAX 500kbps
39VSS40SYS REQOCommunication request from system µ-com
41PAN REQICommunication request from panel
42SDAI/OI2C data input output
43SCLI/OI2C clock input output
44PON PANELI/OPanel 5V control
45DSII/ODSI control
46~49NC-Not used.
50PM MOT1OPanel motor control 1Refer to Truth Value Table w
51PM MOT2OPanel motor control 2Refer to Truth Value Table w
52EPMIFlash EPM
53PM OPENIPanel full open detectionRefer to Truth Value Table e
54~56NC-Not used
57P5V DISI/OPanel 5V discharge controlH : Discharge, Other : Hi-Z
58PM CLOSEIPanel mechanism close detectionRefer to Truth Value Table e
59ROMCOR DETIE2PROM write requestH : Write
60PM DETIPanel mechanism detectionH : Function check in progress
61SC CONO
62NC-Not used
63TUN TYPE1IDestination setting 1
64TUN TYPE2IDestination setting 2
65,66NC-Not used
67
67NCONot used when MDOutput L fixed when MD
68CD LOS SWICD loading detection
68
69CD MUTE RICD mute (Rch) requestL : Rch mute request
69NCONot used when MDOutput L fixed when MD
70CD MUTE LICD mute (Lch) requestL : Lch mute request
70MD_MUTEIMD MUTE request terminalL : MUTE request
71CD MRSTOCD mechanism microcomputer resetL : Reset, H : Normal
71MD_MRSTOMD mechanism µ-com RST terminalH : Normal, L : RESET
72CD MSTOPOCD mechanism microcomputer stop
72MD_MSTOPOMD mechanism µ-com stop terminal
73CD_DISC8_SWICD disc detection terminal (8cm) (J only)
73NC-Not used
CD DISC12 SW
MD_LOS_EJE_SW
Inside-panel communication (Chip enable when flash)
I12cm CD detection
IMD DISC position detection terminal
ON : H (Momentary power down/Panel detached)
11 Minutes after ACC OFF : Hi-Z
POWER OFF, ACC OFF : L
TUN TYPE1 : L, TUN TYPE2 : L
Refer to Truth Value Table t
TUN TYPE1 : L, TUN TYPE2 : L
Refer to Truth Value Table t
L : Mechanism microcomputer stop,
H : Mechanism microcomputer in operation
H : Mechanism µ-com in operation,
L : Mechanism µ-com stop
7
KDC-MP732
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No.Pin NameI/OFunctionProcessing Operation
74
74
75CD LOEJI/OCD motor controlRefer to Truth Value Table q
75MD_LOEJI/OMD motor control terminalRefer to Truth Value Table q
76CD MOTOROCD motor controlRefer to Truth Value Table q
76MD_MOTOROMD motor control terminalRefer to Truth Value Table q
77PON ILLUMII/OK e y illumination pow er supply controlON : H, OFF : Hi-Z
78PON CDI/OCD/WMA power supply controlAt time of CD source: H, Other than CD : Hi-Z
78PON_MDI/OMD servo power supply control terminal
79PONOPower supply controlPOWER ON : H, POWER OFF : L
80PON FL+BO
81PON FDCI/O
82F SEL1OSW-Reg frequency switching
83F SEL2OSW-Reg frequency switching
84DIAGI/OP-CON excess current surveillance
85VCC286EXT AMP CONI/OExternal amplifier control
86NCONot usedFixed to L-output for models without EXT_AMP
87VSS88~91
92NC-Not used
93
93NCONot used with DISP OUTOutput L fixed
94
94NCONot used with DISP OUTOutput L fixed
95OEM DISP CEI/OExternal display control requestExternal display
95NCONot used with DISP OUTOutput L fixed
96NC-Not used.
97P CONOExternal amplifier controlPOWER ON : H, POWER OFF or STANDBY : L
98NC-Not used.
99ANT CONTOPower antenna controlTUNER ON : H
100ILLUMI DETIDimmer illumination detectionL : ON, H : OFF
101BU DETIMomentary power down detectionBU : L, No BU or momentary power down : H
102ACC DETIACC power supply detectionACC ON : L, ACC OFF : H
103(PWIC SVR)OSVR discharge circuit
104PWIC MUTEOPower IC mute
105PWIC STBYOPower IC standby controlPOWER ON : H, POWER OFF : L
106LX CONOStart up request to slave unitH : SLAVE UNIT ON, L : SLAVE UNIT OFF
CD LOE LIM SW
MD_LOE_LIM_SW
TYPE 1~TYPE4
OEM DISP DATA
OEM DISP CLK
ICD detection (Chucking SW)H : Loading complete, L : No disc
IMD detection terminal (chucking SW)H : Loading completed, L : No disc
H : When MD mechanism in operation,
Hi-Z : When other than MD source
Fruorescent indicator tube bias power supply control
Fruorescent indicator tube filament power supply control
IDestination switchingRefer to Truth Value Table y
I/OExternal display DATAExternal display
I/OExternal display CLKExternal display
POWER ON : H, POWER OFF or display black out : L
POWER ON : L, POWER OFF or display black out : Hi-Z
H : 5 seconds after POWER OFF and momentary
power down, Then : L
L : When STANDBY source or momentary power
down, L : When TEL MUTE
8
KDC-MP732
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No.Pin NameI/OFunctionProcessing Operation
107MUTE PRE RORch pre-out mute
107NCONot used when MDOutput L fixed
108
108MUTE_PREOPRE_OUT MUTE (MD)L : When at momentary power down
109MUTE 0OE-VOL front muteON : L, OFF : H
110MUTE 1OE-VOL rear muteON : L, OFF : H
111MUTE 2OE-VOL sub muteON : L, OFF : H
112NCONot used
113DSP MUTEI/ODSP muteON : L, OFF : Hi-Z
113NCONot used when without DSPOutput L fixed
114MUTE COE-VOL AFS muteON : L, OFF : H
114NCONot used (in other than when the destination is E)Output L fixed
115DSP INIT RSTODSP initial resetL : Reset, H : Reset release
115NCONot used when without DSPOutput L fixed
116DSP S RSTODSP system resetL : Reset, H : Reset release
116NCONot used when without DSPOutput L fixed
117DSP RQORequest to DSPL : Request
117NCONot used when without DSPOutput L fixed
118DSP CSODSP chip selectL : Select
118NCONot used when without DSPOutput L fixed
119NC (GTEST)ONot used
120LINE MUTEILine mute detect
121MD DETIFor a terminal of MD receiver
121NCONot used when CDOutput L fixed
122PWIC DC DETIDC offset error detect
123LX RSTOHard reset to slave unitH : Reset, L : Normal
124G Y OUTIAnalog Y gravity detect
124NCONot used when without G sensorOutput L fixed
125G X OUTIAnalog X gravity detect
125NCONot used when without G sensorOutput L fixed
126RDS NOISEIFM noise detection
127AVSS128TUN SMETERIS-meter input
CD MUTE PRE L
OLch pre-out mute
L : When “MUTE PRE R” is “L” or at momentary
power down, H : Only when 2-zone
L : When “MUTE PRE L” is “L” or at momentary power
down, H : Only when 2-zone
TEL MUTE : 1V or less,
NAVI MUTE : 1V or less, 2.5V or more
9
KDC-MP732
MICROCOMPUTER’S TERMINAL DESCRIPTION
Truth Value T able
q CD MOTOR / CD LOEJ
CD MOTOR
StandbyLL
EjectHH
LoadHL
BrakeHHi-Z
CD LOEJ
r RDS AFS
RDS AFS M RDS AFS L
AFS LOWLL
AFS MIDLHi-ZSound output with AF search
AFS HIGHHi-ZHi-ZNormal reception
No sound output with AF search
Condition
w PANEL MOTOR
OPENCLOSESTOPWAIT
PM MOT1LHHL
PM MOT2HLHL
e PANEL MECHA
FULL OPEN FULL CLOSEOTHER
PM OPENHLL
PM CLOSEHLH
t TUN TYPE setting
TYPE1TYPE2
Kenwood brand modelLL
Setting for OEM1LH
Setting for OEM2HL
Setting for OEM3HH
1~7D14~D8I/OData input/output
83.3VDD-3.3V
9VSS-Connect to GND
10~17D7~D0I/OData input/output
18FLGCP1OFL harmony control
19NC-Not used
20SYS REQISystem µ-com communication requestH : Data communication
21SC CONI
22FL BKOFruorescent indicator blackout controlH : Fruorescent indicator turned on, L : turned off
232.5VDD-2.5V
24VSS-Connect to GND
25NC-Not used
26,27KS1, KS2I/OKey scanL : Output, Hi-Z : Switching
28,29TD0, TD1-Not used
30,31KS3, KS4I/OKey scanL : Output, Hi-Z : Switching
32TRSTIPull down
System µ-com communication/Panel operation control
Lighting timing (brightness harmony) is controlled
with pulse interval. GCP=FLGCP1+FLGCP2
44PAN REQOPanel communication requestH : Data communication in progress
45SYS DATAIData reception from system µ-comUART communication 500kbps
46PAN DATAOData transmission from panelUART communication 500kbps
47FL CLKO
48KR4 INTIKey returnInterruption possible
49FL DATA1OFruorescent indicator serial control data
50CLK IN3ISerial synchronization clockSynchronized to Fruorescent indicator CLK
51FL ELOFruorescent indicator skip shift controlH or Hi-Z : Odd number skip, L : Even number skip
52FL DATA2OFruorescent indicator serial control data
53CLK IN2ISerial synchronization clockSynchronized to Fruorescent indicator CLK
54FL LATOFruorescent indicator latch control
55FL DATA3OFruorescent indicator serial control data
563.3VDD-3.3V
57,58X2,X1IClock6.6MHz
59CVSS-Connect to GND
60CKSEL-Connect to GND
61PSEL-Connect to VDD
622.5VDD-2.5V
63VSS-Connect to GND
64MODE0-Connect to GND
65MODE1-Pull down
66PAN RSTIInput from reset IC
67AVDD1ID/A conversion reference voltageConnect to D3.3V
68,69NC-Pull down
70,71AVSS1,AVSS0-D/A conversion reference GND
72AVDD0-A/D conversion reference voltageConnect to D3.3V
73WAVE INIVoice inputAD read
74F01IBPF (63Hz)AD read
75F02IBPF (150Hz)AD read
76F03IBPF (330Hz)AD read
77F04IBPF (1kHz)AD read
78F05IBPF (3.3kHz)AD read
79F06IBPF (10kHz)AD read
80NC-Pull down
Fruorescent indicator serial communication reference clock
Lighting timing (brightness harmony) is controlled
with pulse interval. GCP=FLGCP1+FLGCP2
Reference clock 4.125MHz
11
KDC-MP732
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No.Pin NameI/OFunctionProcessing Operation
812.5VDD-2.5V
82VSS-Connect to GND
83NC-Not used
84TYPEI
85
86REMOIRemote controller signalDetection with pulse width
87PON FL+BOFruorescent indicator bias power supply switchH : ON, L : OFF
88PON FLVDDI/O
89PON 5VI/O5V power supply switch
90~93NC-Not used
94WEI/OMemory data write permissionL : Write, H : Wait SW3.3V start up : Hi-Z
95OEI/OMemory data transmission permission
96,97NC-Not used
983.3VDD-3.3V
99VSS-Connect to GND
100FROMCHK-Not used
101CEI/OMemory operation permissionL : Operation, H : Wait SW3.3V start up : Hi-Z
102~104
105ROMCOR SCL-For ROM correction
106ROMCOR SDA-For ROM correction
107NC (SEL E2P)-Not used
108
109PON TRI REDI/OTriangle red light ON switchH : Light ON, Hi-Z : Light OFF
110PON BLUEI/OBlue sub-illumination light ON switchH : Light ON, Hi-Z : Light OFF
111SA RSTOSpectrum analyzer IC resetH : Reset (1.8V or higher), L : Normal
1123.3VDD-3.3V
113EVSS-Connect to GND
114PON GREENI/OGreen key illumination light ON s witchH : Light ON, Hi-Z : Light OFF
115PON REDI/ORed illumination light ON switchH : Light ON, Hi-Z : Light OFF
116PON SW3VI/ORotary encoder power supplyL : ON, Hi-Z : OFF
117NCONot used
118~123
1242.5VDD-2.5V
125VSS-Connect to GND
126~133
1343.3VDD-3.3V
135EVSS-Connect to GND
136~142
143NC-Not used
144D15I/OData input/output
NC (VREFCON)
NC-Not used
PON TRI GREEN
A21~A16OAddress output
A15~A8OAddress output
A7~A1OAddress output
Whether there is customizing or not designation setting
ONot used
Fruorescent indicator logic section power supply switch
I/OTriangle green light ON switch
H : Flash ROM (This model), L : Mask ROM (Other model)
H : ON, Hi-Z : OFF
Remote controller IC / Space analyzer IC power
supply H : ON, Hi-Z : OFF
L : Data transmission, H : Wait SW3.3V start up : Hi-Z
H : Light ON, Hi-Z : Light OFF, When blackout : Light ON
1NC-Not used.Low-fixed
2E2P SCLI/O Rom correction E2P I2C clock
3~5NC-Not used.Low-fixed
6VDD-5V electric potential
7GND-GND electric potential
8,9NC-Not used.Low-fixed
10,11PON1,PON2OPower ON/OFF controlH : ON, L : OFF
12LOE/LIM SWIDown-limit SW detectionL : Lim detection
13DAC MUTEODAC MUTE controlH : MUTE ON, L : MUTE OFFWith DXM-6580W (X32-574), open and
14DAC RSTODAC RESETH : NORMAL, L : RESETWith DXM-6580W (X32-574), open and
15EMPHOExternal DAC Emphasis control
16,17NC-Not used.Low-fixed
18IC/Vpp-Write voltage (FLASH)
19MUTE LOLch audio MUTE controlL : MUTE ON, H : MUTE OFF
20MUTE RORch audio MUTE controlL : MUTE ON, H : MUTE OFF
21TYPEIDAC switching
22TEST O 1OTEST MODE O 1(Not used.)
23TEST O 2OTEST MODE O 2(Not used.)
24TEST O 3OTEST MODE O 3(Not used.)
25TEST O 4OTEST MODE O 4(Not used.)
26NC-Not used.Low-fixed
27WAITIWait control signal detection
28~30NC-Not used.Low-fixed
31RESETIReset detectionH : NORMAL, L : RESET
32XT1INot used.
33XT2-Not used.
34REGC35X236X1I
37Vss-GND electric potential
38VDD-5V electric potential
39NC-NCOutput stopped in standby3.3V driven
40WRLIMultiplex WRITE signal3.3V driv en
Processing Operation
Description
H : Emphasis ON,
L : Emphasis OFF
L : Normal operation,
H : In writing.
H : DSP built-in DAC used,
L : DSP built-in DAC Not used.
Remarks
Used with DXM-6680W (X32-586).
L-fixed.
Used with DXM-6680W (X32-586).
L-fixed.
Used with DXM-6680W (X32-586).
With DXM-6580W (X32-574), open and
L-fixed.
76RZMI0bit MUTE detectionH : ≥1.7V, L : <1.7V
77LZMI0bit MUTE detectionH : ≥1.7V, L : <1.7V
78AACIAAC compatibility switching
79ASELIAudio output polarity switching
80E2P WRIE2PROM write switching
81TEST I 0ITEST MODE I 0(Not used.)
82TEST I 1ITEST MODE I 1(Not used.)
83TEST I 2ITEST MODE I 2(Not used.)
84TEST I 3ITEST MODE I 3(Not used.)
85,86NC-Not used.Low-fixed
87MSTOPIStandby restart interruptionH : STOP release, L : STOP
88INTSVIInterruption from servo ICH : Interruption
89~92NC-Not used.Low-fixed
93D-MUTEODriver MUTEH : OFF, L : ON
94SYS SDAI/O System µ-com I2C dataFlash write port (SI0)
95NC-Not used.Low-fixedFlash write port (SO0)
96SYS SCLI/O System µ-com I2C clockFlash write port (SCK0)
97~99NC-Not used.Low-fixed
100E2P SDAI/O ROM correction E2P I2C data
With DRAM/No DRAM switching
for different models
Processing Operation
Description
H : With DRAM, L : No DRAM
H : AAC non-compatible,AAC non-compatible mode has priority
L : AAC compatiblefor both hardware and software.
H : Reverse output,
L : Non-reverse output
H : E2PROM WRITE,
L : NORMAL
Remarks
14
TEST MODE
KDC-MP732
●How to enter the test mode
In order to enter the test mode, reset the unit while simultaneously pressing down [1] and [3] keys.
(While “----” is being displayed, power can be ON for 30 minutes.)
●How to clear the test mode
The test mode is cleared in case of any of the following e v ents:
resetting, momentary power down, Acc OFF, P ower OFF and
removal of the panel.
●Initial conditions of the test mode
• Source is STANDBY.
• Displays lights are all turned on.
• The volume is at –10dB (The display is 30).
• Loudness (LOUD) is OFF.
• CRSC is OFF, regardless of whether there are switching
functions or not.
• SYSTEM Q is NATURAL (=FLAT).
• BEEP will sound anytime with a less than 1 second push.
• Auxiliary (AUX) is ON.
• DISPLAY TYPE is TYPE D.
• The Multi-function Key System are source dependent systems. (TUNER → Preset, CD / CD-CH → Scan, etc.)
• Display of TUNER sources will be as follows :
European Models : Upper Display=PS/frequency, Middle
Display=spectrum analyzer, Lower Display=multi-function
Other Models : Upper Displa y=SNPS, Middle Display =spectrum analyzer, Lower Display=multi-function
• CD source display will be as follows :
All Models : Upper Displa y=P-TIME, Middle Displa y= spectrum analyzer, Lower Display=multi-function
●RDS automatic measurement
Conventionally, the PS display has been visually checked on
the production line. This will be replaced b y a ne w processing.
The PS data will be received and the PS contents is to be
verified as “RDS_TEST”. When this is verified, the P-CON
terminal is forced to go OFF. (In this case, “ _ ” means blank.)
→ This will be a dedicated test mode processing.
On the P-CON, when power is turned off once and, then,
turned on again, (Power OFF → ON) the unit will be restarted.
●Special display when set to TUNER
When in TUNER mode , if any of the f ollowing displays appear,
there is an abnormality with the front end.
• “TNE2P_NG” : Front-end E2PROM values are still default
(not determined).
•“TNCON_NG” : In this condition, the communication with
the front-end is not possible.
●Forced switching of K3I
In TUNER FM mode, each time [6] key is pressed, the functions move in the following cycle :
AUTO → forced WIDE → forced MIDDLE → force NARROW
→ AUTO
The initial condition is AUTO and the displays below will appear.
• AUTO : FMA
• Forced MIDDLE : FMM
• Forced WIDE : FMW
• Forced NARROW : FMN
●CD receiver test mode specifications
•Jumps are made to the following tracks by pressing the
[
No.22 → No.14 → No.9 (Returns to the beginning)
It must be noted, however, that when paying MP3 / WMA /
AAC disk, which contain 8 files or less, the first track and
the following trac ks are played in order.
• When [
• When a CD is used as a source, by pressing [1] key f or less
than 1 second, a jump to the Track No. 28 is made.
• When a CD is used as a source, by pressing [2] key f or less
than 1 second, a jump to the Track No. 14 is made.
• When a CD is used as a source, by pressing [3] key f or less
than 1 second, a display of CD mechanism model name
and its version is made. When the pressing of [3] key for
less than 1 second is made for the second time, the normal
display is resumed. (Time code display)
• While in CD source, use [5] key to switch between DSP
Through and DSP Bypass. (In models with DSP)
The multi-function key
dicates Bypass.
• When a CD is used as a source, by pressing [6] key f or less
than 1 second, a jump to the Track No. 15 is made. At the
same time, the volume value is set to 27 (5V PRE).
] key is pressed, it goes down by 1 track.
5
indicates Through, and 5 in-
15
KDC-MP732
TEST MODE
●Audio adjust mode
Model with DSP (KDC-W8534/W8534Y)
•By pressing [AUD] key for less than 1 second, the Audio
Adjust mode is entered.
• As with the [AUD] key, [∗] key on the remote controller can
be used to enter the Audio Adjust mode.
• As for the adjustment items, items for both the AUDIO
FUNCTION MODE and SETUP MODE are included.
• By pressing [AUD] or [FM] key briefly, switch the item to be
adjusted in the following order. (only in forward rotation)
• The initial item will be Fader and the next is Balance. (After
Balance, it will be arbitrary.)
• With the remote controller, continuous forwarding is prohibited.
• Using the V OL knob and [] / [] key, the Fader is to be
adjusted to the following 3 levels : R15 ↔ 0 ↔ F15 (The
default value : 0)
• Using the VOL knob and [
be adjusted to the following 3 le v els : L15 ↔ 0 ↔ R15 (The
default value : 0)
• Using the VOL knob and [
set is to be adjusted to the following 2 le vels : –8 ↔ 0 (The
default value : 0)
] / [] key, the Balance is to
] / [] key, the Volume Off-
• Using the VOL knob and [
Level can be adjusted in 3 steps : –15 ↔ 0 ↔ +15 (The
initial value is 0)
• Using the VOL knob and [
set can be adjusted in 2 steps : –8 ↔ 0 (The initial value is
0)
• Using the VOL knob and [
Rear can be adjusted in 2 steps : Through ↔ 180Hz (or
220Hz) (The initial value is Through)
• Using the VOL knob and [
Woofer can be adjusted in 2 steps : 60Hz (or 50Hz) ↔
Through (The initial value is Through)
• Using the VOL knob and [
set can be adjusted in 2 steps : –8 ↔ 0 (The initial value is
0)
• Using the VOL knob and [
ON/OFF can be adjusted in 2 steps : OFF ↔ ON (The
initial value is OFF)
• Using the V OL knob and [
can be adjusted in 2 steps : OFF ↔ ON (The initial value is
OFF)
• Bass f / Bass Q / Bass EXT / Middle f / Middle Q / Treble f
do no appear in audio adjustments.
] / [] key, the Sub Woofer
] / [] key, the Volume Off-
] / [] key, the HPF Front /
] / [] key, the LPF Sub
] / [] key, the Volume Off-
] / [] key, the Loudness
] / [] key, 2-Zone ON/OFF
Model with no DSP (KDC-X790/MP732/MP8533)
• By pressing [AUD] key for less than 1 second, the audio
adjustment mode can be entered.
• Using the remote controller [∗] key and [AUD] key, the audio adjustment mode can be entered.
•Adjustment items of both the AUDIO FUNCTION MODE
and SETUP MODE are included.
• By pressing [AUD] or [FM] key briefly, switch the item to be
adjusted in the following order. (only in forward rotation)
• The initial item will be Fader , which is followed by : Balance
→ Bass Le v el → Middle Level → Treble Le v el → HPF Front
→ HPF Rear → LPF Sub Woofer (After this, it will be arbi-
trary)
• With the remote controller, continuous forwarding is prohibited.
• Using the V OL knob and [] / [] key, the Fader can be
adjusted in 3 steps : R15 ↔ 0 ↔ F15 (The initial value is 0)
• Using the VOL knob and [] / [] key, the Balance can
be adjusted in 3 steps : L15 ↔ 0 ↔ R15 (The initial value is
0)
• Using the V OL knob and [
/ Treble Level can be adjusted in 3 steps : –8 ↔ 0 ↔ +8
(The initial value is 0)
] / [] key , the Bass / Middle
●MENU items
• Push the [] (NEXT) key for at least 1 second to enter the
MENU.
• The [DNPP/SBF] and [DIRECT] keys on the remote controller can also be used to enter the MENU.
• With the remote controller, continuous forwarding is prohibited.
• When a CD is used as a source, the default item will be the
ACD F/W Version.
(DXM-6800 mechanism equipped model : KDC-W8534/
W8534Y, KDC-X790)
●2-ZONE (Dual Zone) items
• When using sources other than the STANDBY source, using a short-press on [AUTO] or [TI] key, 2-ZONE ON/OFF
is achieved.
●Backup current measurement
When reset in Acc OFF (Back Up ON) condition, MUTE terminal goes off after 2 seconds, instead of 15 seconds. (During
this time, the CD mechanism does not function.)
16
Loading...
+ 36 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.