1AM+BOAM power terminalH: During AM radio operation
2FM+BOFM power terminalH: During FM radio operation
H: During FM radio operation if with RDS, RBDS
3
AFS
4PLL-DATAI/O Data I/O terminal to F/E
5PLL-CLKI/O CLK terminal to F/E
6Evdd-Positive power terminal
7Evss-GND terminal
8N.COOpen (not used)
9BEEPOBEEP output terminal
10N.COOpen (not used)
11PRE-MUTE LOL (during CD): when M MUTE L is L (low)
12PRE-MUTE ROL (during CD): when M MUTE R is L (low)
13IC2-SDAI/O IC2, IC5, CD mechanism, DATA line
14IC2-SCLOIC2, IC5, CD mechanism, CLK line
15N.COOpen (not used)
16N.COOpen (not used)
17N.COOpen (not used)
18TEST-Test terminal
19P-MUTEOPower IC MUTE terminalL: During Power-OFF L: During All-OFF
20P-STBYOPower IC STBY terminal
21MUTEOMUTE termianlON: Open OFF: L
22N.COOpen (not used)
23N.COOpen (not used)
24ACC-DETIACC detection terminalL: ACCH: No ACC
25DIMMERISmall detection terminalON: LOFF: H
26SW5VO5 volt power terminalON: LOFF: H
27EXT-AMP-COOExternal AMP control terminal (200ms)L 40ms: Bus boost OFF
28P-CONOPower control terminalPower ON: HPower OFF: L
29ANT-CONOAntenna control terminalTUNER, TI ON: H Open if no ANT-CON
30P-ONOSW14V control terminalPower ON: HPower OFF: L
31
RESET
32XT1ISubclock terminalTime countOperation during Power-OFF
33XT2-Subclock terminal
34REGC35X2-Main clock terminalOscillates: During Power-ON
36X1IMain clock terminal
37Vss-GND terminal
38Vdd-+B terminal
39CLKOUTOInternal system clock output
40N.COOpen (not used)
41N.COOpen (not used)
42TYPE0IDestination selector port
43TYPE1IDestination selector port
44TYPE2IDestination selector port
45N.COOpen (not used)
46IC2TYPE0IIC2 destination terminalL: During default
OSwitching terminal for noise detectionL: During AF search, FM seek
H: During receive
L during momentary power down
Fixed at H only during 2 zone
L during momentary power down
Fixed at H only during 2 zone
L: During Tell-mute
Power IC ON: H. Power IC OFF: L. During All-OFF: H
L 70ms: Bus boost LOW
L 100ms: Bus boost HI
IReset IN terminalH: NormallyH: During reset
Capacitor output terminal for regulator inside microprocessor
Oscillates stop: During Power-OFF, during
momentary power down
3
KDC-8090R
MICROCOMPUTER'S TERMINAL DESCRIPTION
PinFunctionI/ODescriptionProcessing Operation
47IC2TYPE1IIC2 destination terminalL: During default
48
CH-REQH
49CH-RSTOReset output to changerNormally L, after system RST reset is ”H” for
50CH-MUTEIMute request from changerON: HOFF: L
51CH-CONOChanger control outputON: HOFF: L
52ILL-ONOFL, illumination outputON: HOFF: L
53M-MUTE LIMute request from CD mechanismON: L
54M-MUTE RIMute request from CD mechanismON: L
55BVdd-+B terminal
56BVss-GND terminal
57M-RSTOReset output to CD mechanismNormally H,L:During reset
58M-STOPOStop request to CD mechanismStop: LH: During CD
59N.COOpen (not used)
60LO/EJI/O CD mechanism, LODING, EJECT selectorStop, Brake: Hi-z, LOADING: L, EJECT: H
61MOSWOCD mechanism, MOTOR, SWLOADING, EJECT, Brake: H
62N.COOpen (not used)
63CD-SW3ICD down SW detection terminalChucking: H
64PAN-RESETOReset output to panel microprocessor
65MC-REQ/PANI/O
66N.COOpen (not used)
67N.COOpen (not used)
68N.COOpen (not used)
69N.COOpen (not used)
70AVCONTOAD reference voltage control outputSame timing as P ONH: During operation
71Avdd-+B terminal
72Avss-GND terminal
73AvrefI
74PHONEIPHONE detection terminalTel mute: Min 1 volt, Navi mute: Max.2.5 volt
75SRM-SW3IMask mechanism position detection inputSee 01mask mechanical position detection chart
76SRM-SW1IMask mechanism position detection inputSee 01mask mechanical position detection chart
77SRM-SW2IMask mechanism position detection inputSee 01mask mechanical position detection chart
78SRM-DETIMask mechanism detection inputL: MechanismH: No mechanism
79NOISEIFM noise detection terminal
80S-METERIS meter detection terminal
81R-DATAIRDS DECODER DATA input terminalConnect to GND: On models without RDS,
82R-QUALIRDS DECODER QUAL input terminalConnect to GND: On models without RDS,
83IFC-OUTIF/E IFC OUT input terminalL: When station present
84N.CIOpen (not used)Connect to GND
85N.CIOpen (not used)Connect to GND
86SRM-BOSRM mechanical submotor output terminal
87R-CLKIRDS DECODER CLK input terminalConnect to GHD: On models without RDS,
88CH-REQCIInput request from changerON: L
89SC-REQI
90CD-SW1ILOADING SW detection terminalLOADING start: L
91CD-SW2I12cm disk detection switch terminal12cm DISC: L
92SRM+BOSRM mechanical submotor output terminal
93BU-DETIMomentary power down detection terminalL: B.UH: No B.U (momentary power down)
94CH-DATACIData input terminal from changer
95CH-DATAHOData input terminal to changer
96CH-CLKI/O CLK I/O terminal used with changer
97SC-DATAIData line from panel microprocessor
98MC-DATAI/O Data line to panel microprocessor
99MC-CLKOCLK terminal to panel microprocessor
100 PAN5VOPanel 5 volt control terminalL: PanelH: No panel
ORequest output to changer
REQ terminal/panel detection for panel microprocessor
Reference voltage supply terminal for A/D converter
Communication request from panel microprocessor
400ms and then ”L”
Per mechanical control specs.
Normally H, L: During reset, momentary power down
L: During panel use
RBDS
RBDS
RBDS
4
ADJUSTMENT
KDC-8090R
Test Mode
1. How to enter test mode
While holding the FM key and the Preset 6 key, reset the
unit.
2. How to exit from test mode.
While holding down the Preset 6 key, reset the unit.
Note: Does not exit from test mode ACC-OFF, Power-OFF
or Momentary power down
3. Test mode reset status
•Sources are all OFF
•All display segment lit up
•Volume at -10dB (shows 30 on display)
•LOUD is OFF.
•CRSC is OFF regardless of whether switching function is
provided.
•SYSTEM Q is in FLAT
•Blank skip is OFF. (C/R model)
•LEDs are white, no scanning. (VLCD model)
4. Special displays in Tuner
When the following displays appear in tuner mode it shows
a problem with the front end.
•“TNE2P NG” ..... F/E is not aligned and EEPROM is in
reset (no settings) such as when shipped.
•“TNCON NG” .... Cannot communicate with F/E (front
end).
5. K3I switching
Each time the Preset 6 key is pressed in Tuner mode,
switches one at a time through the following sequence:
AUTO → Forced Wide → Forced Middle → Forced Narrow
→ AUTO. When reset, displays the following in AUTO.
•AUTO ................ FMA
•Forced Wide ..... FMW
•Forced Middle ... FMM
•Forced Narrow .. FMN
6. CD receiver test mode specifications
•No automatic ejection during reset-start. Does not make a
CD check in reset with a CD loaded.
•Using the Track up key jumps to the following tracks.
No.9→No.15→No.10→No.11→No.12→No.13→No.14→and
back to No. 9
•Using the Track down key moves 1 track downwards from
the track being played.
7. Audio items
•Momentarily pressing the Q key calls up audio adjustment
mode.
•Pressing the ∗ key on the remote control calls up audio
alignment mode.
•Continuous forward is disabled on the remote control.
•Bass/Middle/Treble are settable in 3 steps of MIN/
CENTER/MAX with the Track up/down keys.
•Balance is settable in 3 steps of Left MAX/CENTER/Right
MAX with the Track up/down keys.
•Fader is settable in 3 steps of Rear MAX/CENTER/Front
MAX with the Track up/down keys.
•HPF is settable in 2 steps of THRU/220Hz with the Track
up/down keys.
•LPF is settable in 2 steps of THRU/120Hz with the Track
up/down keys.
•Bass f/Bass Q/Bass EXT/Middle f/Middle Q/Treble f do
not appear in the audio alignment.
8. Menu items
•Momentarily pressing the CLK key calls up the Menu mode.
•The DNPP/SBF keys on the remote control calls up Menu
mode.
•Continuous forward is disabled on the remote control.
•Calendar adjust, calendar display switching and calendar
memo are eliminated from forward (FL model)
•In color alignment mode, Preset 1 is red, 2 is blue, 3 is
green and 4 is white. (VLCD model).
•Contrast is set in 3 steps of 0, 5, 10 and the reset value is
5. (VLCD/LCD models)
•Brightness adjustment is set in 3 steps of 0, 5, 10 and the
reset value is 10. (Normal FL model)
9. Backup current measurement
The MUTE terminal turns off 2 seconds (not 15 seconds)
after being reset in ACC off (backup on). (The panel, CD
and tape mechanisms are disabled during this time.)
10. Special displays during All-Off with all lamps on
The following displays appear when the preset keys are
pressed with all display segment lit up.
•Automatic panel close is disabled when tape or CD is
inserted. (M&T model)
•Panel operation is disabled at Power-ON or Power-OFF.
(M&T model)
•Panel open and closes with the ATT key. (M&T model)
•No displays such as “CODE OFF” during Power-ON.
•Pressing the TI (AUTO) key during changer operation turns
on 2zone. Cancel by pressing the TI (AUTO) key again.
The P/S dot is lit during 2zone.
•Pressing the CLK key for 1 second or more during All OFF,
calls up the Mask Key (security) write mode.
Security items
• Forced power-ON mode (all models)
Even when writing is permitted by the security function (mask
key), Power-on can be set for a 30 minute period each time
the reset key is pressed while holding down the ATT key
and Preset 4 keys. After 30 minutes elapses, can only be
restored by using reset.
• How to register the security code for EEPROM (F/E)
replacement (coded security models)
1. While holding the FM key and the preset 6 key, reset the
unit.
2. Call up security register mode by pressing the CLK key.
3. Enter the code with the Preset 1/2/3/4 keys.
For example, to enter the number, “3510”....
- Press the Preset 1 key 4 times.
- Press the Preset 2 key 6 times.
- Press the Preset 3 key 2 times.
- Press the Preset 4 key 1 time.
4. Hold down the DISP key for at least 3 seconds and the
message, “RE-ENTER” appears, so once again enter
the code according to Step 3 above.
5. Hold down the DISP key for at least 3 seconds, and the
message, “APPROVED” appears.
6. Cancel test mode. (See, 2. How to cancel the test mode.)
Note: All clear cannot be performed on the security code
for this model.
• Simple way to clear the security code (K type only)
1. During code request mode, press the VOL UP key for at
least 3 seconds while holding down the DISP key.
(---- will disappear)
2. Enter, “KCAR” with the remote controller as described
below. (Same as on 00 model.)
Press the remote controller 5 key twice, and press the
Track Up key. (Enters a “K”)
Press the remote controller 2 key three times, and press
the Track Up key. (Enters a “C”)
Press the remote controller 2 key once, and press the
6
Track Up key. (Enters an “A”)
Press the remote controller 7 key twice, and press the
Track Up key. (Enters an “R”)
3. Security function is canceled and unit sets to All-Off mode.
4. Code request mode appears if a mistake was made in
entering the numbers.
• Mask key write method on initialized EEPROM
1. While holding the FM key and the preset 6 key, reset the
unit.
2. Press the CLK key to call up mouse key register mode.
The message, “TRANSMIT 1” appears. The display at
this time shows “< >“ rather than “[ ]”.
3. Face the mask key towards the photosensor and hold
down for half a second or longer.
4. When “TRANSMIT 2” appears, again hold down the mask
key for at least half a second. The first and second counter
codes are not compared at this time.
5. When the message, “APPROVED” appears, the writing
is complete. The demo mode is set at this time and test
mode is canceled.
Note: Just as with the previous model, if 30 minutes elapses
and the code is not written, then an error is issued and
power-OFF is triggered.
• How to initialize the mask key (Return to factory settings
from mask key write permit status.)
1. While holding the FM key and the preset 6 key, reset the
unit.
2. The message, “TRANSMIT 1” appears and mask key
request mode is called up. The display at this time shows
“∗ ∗” rather than “[ ]”.
3. Cancel the mask key on the remote control by holding
down for at least 3 seconds.
4. When “TRANSMIT 2” appears, again hold down the mask
key for at least 3 seconds.
5. When the message, “APPROVED” appears, the mask
key is canceled, demo mode is set, test mode is canceled,
and the factory settings restored.
• How to All-Clear the mask key
1. While holding the FM key and the preset 6 key, reset the
unit.
2. Press the CLK key to call up mouse key register mode.
The message, “TRANSMIT 1” appears.
3. Face the mask cancel key towards the photosensor and
hold down for 3 seconds or longer (until level reaches
full).
4. When “TRANSMIT 2” appears, again hold down the mask
key for at least 3 seconds. If “TRANSMIT 1” appears at
this time, then redo the procedure, starting from step 3.
5. When the message, “APPROVED” appears, all-clear has
been performed on the security data and operation returns
to the Mask key write method on initialized EEPROM.
IHGEFDCAB
PC BOARD (Component Side View)
1
CD PLAYER UNITCD PLAYER UNIT
CD PLAYER UNIT
(X32-5030-00)
.ON.feR
CIQ
1B4
2C4
2
4D2
5D3
6D3
1B4
2D4
3D3
4C4
5D4
sserddA
3
D1
R8
C5
4
R10
R11
R12
C10
C11
5
FCS+
LD
R9
C4
W17
PD
B
E
C6
C7
C12
R5
Q1
CN1
1
C8
16
R202
IOP+
/RFDET
X32-5030-00 (J74-1161-02)
R83
C45
R82
-
ECS
+
FCS-
16
TRK-
32
17
C2
+
-
BDO
R3
C1
TE
FE
ARF
S.GND
C
C16
A
R234
TE
FOD
EJECT/SLED-
CP3
A.+B
R6
F
Vcc
Vc
1
C18
R17
TBAL
GCTL
-
+
RF
F
IC1
C89
TRCRS
GND
IOP-
LOAD
SLED+
SW3
S.+B
TRK+
VR
R72
C43
R71
Rch
C3
D
B
FBAL
VDET
TR
+
1
CN2
22
R19
R233
LDON
OFT
R81
R73
-
R75
+
TVD
RW
D4
R218
C19
C20
R21
R20
C15
C14
R16C13
R15
2551
C17
R18
C23
Vref
E
A.GND
C55
1
C33
26
TOFS
R36
Lch
C35
R32
R34
CP2
CP1
R47
S3
Q4
C85
R54
C26
C29
R38 C25
SPDL-
BE
CLVS
IC2
R37
IPFLAG
C24
C28
/MSTOP
/MRST
C21
76100
X1
50
FCLK
FLAG
SPDL+
C46
BU.5V
75
DQSY
STLD
ST-O
R76
R44C51
Q3
R107
R52
R213
LDCNT
SMCK
14
1
EB
C34
R45
R49
D.OUT
R46
S2
IC4
/MUTEL
/MUTER
LO/EJ
R125
R117
Q2
EBEB
C41
R77
C79
8
C77
5
C71
R121
D2
S1
IC5
I
C67
GO
R103
D3
SW2
28
R78
15
A.5V
IC6
D.GND
MOTOR
C63
+
C80
1
4
C72
C68
/RST
Q5
C78
R104
/CLK
SW1
R122
DATA
R126
R118
R102
R108
PC BOARD (Foil Side View)
X32-5030-00 (J74-1161-02)
IC4
R77
/MUTEL
/MUTER
LO/EJ
I
8
5
C67
R103
D.OUT
D2
S1
C41
C77
R121
Q2
C34
R45
14
R125
R117
1
R44C51
EB
R49
R46
S2
LDCNT
R76
Q3
R107
SMCK
ST-O
/MRST
SPDL+
BU.5V
R213
DQSY
STLD
/MSTOP
R52
C46
75
51
FCLK
76
50
SPDL-
C21
CLVS
X1
C24
C28
C25
FLAG
IPFLAG
IC2
R37
C85
R54
C26
R38
R81
-
R75
+
-
S3
TVD
EJECT/SLED-
A.GND
Lch
CP2
CP1
E
B
R47
Q4
C55
RW
100
D4
1
C29
C35
R32
R34
TOFS
R36
R218
C20
C33
R21
R20
R15
R16
C14
25
C17
C13
26
C23
Vref
R18
R233
LDON
E
OFT
R108
R102
DATA
/CLK
MOTOR
R126
R118
SW1
R122
/RST
C78
C72
+
C80
1
4
R104
D.GND
A.5V
C68
SW2
Q5
28
15
C63
D3
R78
IC5
GO
C79
IC6
C71
BBEE
R72
C43
R73
+
1
22
R19
C19
C15
FBAL
VDET
Rch
CN2
C3
FOD
S.GND
A.+B
Vcc
Vc
D
B
R17
TBAL
GCTL
RF
TR
R71
CP3
R6
F
1
R234
-+
TE
F
A
TE
ARF
R83
C45
TRK-
R3
C18
C
FE
R82
ECS
+
LOAD
SLED+
SW3
S.+B
TRK+
FCS-
C1
16
32
17
C16
C2
+
-
TRCRS
BDO
/RFDET
CD PLAYER UNIT
(X32-5030-00)
.ON.feR
CIQ
1H4
2G4
4F2
5F3
6F3
1H4
2F4
3F3
4G4
5F4
FCS+
LD
VR
PD
R5
CN1
1
IC1
16
C89
R202
GND
IOP+
IOP-
D1
R8
R9
C4
W17
B
Q1
E
C5
R12
C6
R10
R11
C7
C8
C10
C12
C11
sserddA
6
Refer to the schematic diagram for the values of resistors and capacitors.
7
78
Loading...
+ 15 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.