Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)
Lead free solder used in the board (material : Sn-Cu, melting point : 230 Centigrade)
Signal-to-Noise Ratio80 dBA (reference: 1 W into 4Ω)
Line-Out or Subwoofer-Out Level/Impedance5 V/20 kΩ load (full scale)
Output Impedance≤ 600Ω
TUNER SECTION
FMFrequency Range200 kHz step: 87.9 MHz to 107.9 MHz
Usable Sensitivity9.3 dBf (0.8 µV/75Ω)
50 dB Quieting Sensitivity16.3 dBf (1.8 µV/75Ω)
Alternate Channel Selectivity (400 kHz)65 dB
Frequency Response40 Hz to 15 000 Hz
Stereo Separation40 dB
AMFrequency Range10 kHz step: 530 kHz to 1 700 kHz
Sensitivity/Selectivity20 µV/40 dB
CD PLAYER SECTION
Signal Detection SystemNon-contact optical pickup (semiconductor laser)
Number of Channels2 channels (stereo)
Frequency Response5 Hz to 20 000 Hz
Signal-to-Noise Ratio102 dB
Wow and FlutterLess than measurable limit
USB SECTION
USB StandardUSB 1.1, USB 2.0
Data Transfer Rate (Full Speed)Max. 12 Mbps
Compatible DeviceMass storage class
Compatible File SystemFAT 32/16/12
Playable Audio FormatMP3/WMA/WAV
Maximum Supply CurrentDC 5 V 1 A
BLUETOOTH SECTION
VersionBluetooth 2.1 certified (+EDR)
Power ClassClass 2 Radio
Service Area10 m (10.9 yd)
ProfileHFP 1.5, OPP 1.1, A2DP 1.2, AVRCP 1.3, PBAP 1.0
GENERAL
Power Requirement (Operating Voltage)DC 14.4 V (11 V to 16 V allowance)
Grounding SystemNegative ground
Allowable Operating Temperature0°C to +40°C (32°F to 104°F)
Dimensions
(W × H × D)(approx.)
Mass1.4 kg (3.1 lbs) (excluding accessories)
•
Subject to change without notice.
Installation Size182 mm × 52 mm × 159 mm (7-3/16" × 2-1/16" × 6-5/16")
Panel Size188 mm × 59 mm × 13 mm (7-7/16" × 2-3/8" × 9/16")
50 kHz step: 87.5 MHz to 108.0 MHz
9 kHz step: 531 kHz to 1 611 kHz
≤ 1% THD+N
(No.MA526<Rev.001>)2/16
For ASIA
AUDIO AMPLIFIER SECTION
Maximum Power Output50 W per channel
Continuous Power Output (RMS)20 W per channel into 4Ω, 40 Hz to 20 000 Hz at less than 1% total harmonic distortion.
Load Impedance4 Ω (4 Ω to 8 Ω allowance)
Frequency Response40 Hz to 20 000 Hz
Signal-to-Noise Ratio80 dB
Line-Out or Subwoofer-Out Level/Impedance5 V/20 kΩ load (full scale)
Output Impedance≤ 600Ω
TUNER SECTION
FMFrequency Range87.5 MHz to 108.0 MHz
Usable Sensitivity9.3 dBf (0.8 µV/75Ω)
50 dB Quieting Sensitivity16.3 dBf (1.8 µV/75Ω)
Alternate Channel Selectivity (400 kHz) 65 dB
Frequency Response40 Hz to 15 000 Hz
Stereo Separation40 dB
AMFrequency Range531 kHz to 1 611 kHz
Sensitivity/Selectivity
CD PLAYER SECTION
Signal Detection SystemNon-contact optical pickup (semiconductor laser)
Number of Channels2 channels (stereo)
Frequency Response5 Hz to 20 000 Hz
Signal-to-Noise Ratio102 dB
Wow and FlutterLess than measurable limit
USB SECTION
USB StandardUSB 1.1, USB 2.0
Data Transfer Rate (Full Speed)Max. 12 Mbps
Compatible DeviceMass storage class
Compatible File SystemFAT 32/16/12
Playable Audio FormatMP3/WMA/WAV
Maximum Supply CurrentDC 5 V 1 A
BLUETOOTH SECTION
VersionBluetooth 2.1 certified (+EDR)
Power ClassClass 2 Radio
Service Area10 m
ProfileHFP 1.5, OPP 1.1, A2DP 1.2, AVRCP 1.3, PBAP 1.0
GENERAL
Power Requirement (Operating Voltage)DC 14.4 V (11 V to 16 V allowance)
Grounding SystemNegative ground
Allowable Operating Temperature0°C to +40°C
Dimensions
(W × H × D)
Mass1.4 kg (excluding accessories)
Installation Sizeapprox. 182 mm × 52 mm × 159 mm
Panel Sizeapprox. 188 mm × 59 mm × 13 mm
20
µV/40 dB
• Subject to change without notice.
(No.MA526<Rev.001>)3/16
For Europe
AUDIO AMPLIFIER SECTION
Maximum Power Output50 W per channel
Continuous Power Output (RMS)20 W per channel into 4Ω, 40 Hz to 20 000 Hz at less than 1% total harmonic distortion.
Load Impedance4 Ω (4 Ω to 8 Ω allowance)
Frequency Response40 Hz to 20 000 Hz
Signal-to-Noise Ratio80 dB
Line-Out or Subwoofer-Out Level/Impedance5 V/20 kΩ load (full scale)
Output Impedance≤ 600Ω
TUNER SECTION
FMFrequency Range87.5 MHz to 108.0 MHz
Usable Sensitivity9.3 dBf (0.8 µV/75Ω)
50 dB Quieting Sensitivity16.3 dBf (1.8 µV/75Ω)
Alternate Channel Selectivity (400 kHz) 65 dB
Frequency Response40 Hz to 15 000 Hz
Stereo Separation40 dB
AMFrequency RangeMW: 531 kHz to 1 611 kHz
Sensitivity/Selectivity
CD PLAYER SECTION
Signal Detection SystemNon-contact optical pickup (semiconductor laser)
Number of Channels2 channels (stereo)
Frequency Response5 Hz to 20 000 Hz
Signal-to-Noise Ratio102 dB
Wow and FlutterLess than measurable limit
USB SECTION
USB StandardUSB 1.1, USB 2.0
Data Transfer Rate (Full Speed)Max. 12 Mbps
Compatible DeviceMass storage class
Compatible File SystemFAT 32/16/12
Playable Audio FormatMP3/WMA/WAV
Maximum Supply CurrentDC 5 V 1 A
BLUETOOTH SECTION
VersionBluetooth 2.1 certified (+EDR)
Power ClassClass 2 Radio
Service Area10 m
ProfileHFP 1.5, OPP 1.1, A2DP 1.2, AVRCP 1.3, PBAP 1.0
GENERAL
Power Requirement (Operating Voltage)DC 14.4 V (11 V to 16 V allowance)
Grounding SystemNegative ground
Allowable Operating Temperature0°C to +40°C
Dimensions
(W × H × D)
Mass1.4 kg (excluding accessories)
Installation Sizeapprox. 182 mm × 52 mm × 159 mm
Panel Sizeapprox. 188 mm × 59 mm × 13 mm
LW: 153 kHz to 279 kHz
MW: 20
µV/40 dB, LW: 50 µV
• Subject to change without notice.
(No.MA526<Rev.001>)4/16
SECTION 1
PRECAUTION
1.1Safety Precautions
(1) This design of this product contains special hardware and
many circuits and components specially for safety purposes. For continued protection, no changes should be made
to the original design unless authorized in writing by the
manufacturer. Replacement parts must be identical to
those used in the original circuits. Services should be performed by qualified personnel only.
(2) Alterations of the design or circuitry of the product should
not be made. Any design alterations of the product should
not be made. Any design alterations or additions will void
the manufacturers warranty and will further relieve the
manufacture of responsibility for personal injury or property
damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the
protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special
safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features
are identified by shading on the schematics and by ( ) on
the Parts List in the Service Manual. The use of a substitute
replacement which does not have the same safety characteristics as the recommended replacement parts shown in
the Parts List of Service Manual may create shock, fire, or
other hazards.
(4) The leads in the products are routed and dressed with ties,
clamps, tubings, barriers and the like to be separated from
live parts, high temperature parts, moving parts and/or
sharp edges for the prevention of electric shock and fire
hazard. When service is required, the original lead routing
and dress should be observed, and it should be confirmed
that they have been returned to normal, after reassembling.
(5) Leakage shock hazard testing
After reassembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads,
headphone jack, control shafts, etc.) to be sure the product
is safe to operate without danger of electrical shock.Do not
use a line isolation transformer during this check.
• Plug the AC line cord directly into the AC outlet. Using a
"Leakage Current Tester", measure the leakage current
from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the
chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).
• Alternate check method
Plug the AC line cord directly into the AC outlet. Use an
AC voltmeter having, 1,000Ω per volt or more sensitivity
in the following manner. Connect a 1,500Ω 10W resistor
paralleled by a 0.15µF AC-type capacitor between an exposed metal part and a known good earth ground.
Measure the AC voltage across the resistor with the AC
voltmeter.
Move the resistor connection to each exposed metal
part, particularly any exposed metal part having a return
path to the chassis, and measure the AC voltage across
the resistor. Now, reverse the plug in the AC outlet and
repeat each measurement. Voltage measured any must
not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5
mA AC (r.m.s.).
AC VOLTMETER
(Having 1000
ohms/volts,
or more sensitivity)
0.15 F AC TYPE
Place this
probe on
1500 10W
Good earth ground
1.2Warning
(1) This equipment has been designed and manufactured to
meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that
these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant
safety standards.
(4) It is essential that safety critical components are replaced
by approved parts.
(5) If mains voltage selector is provided, check setting for local
voltage.
1.3Caution
Burrs formed during molding may be left over on some parts
of the chassis.
Therefore, pay attention to such burrs in the case of preforming repair of this system.
1.4Critical parts for safety
In regard with component parts appearing on the silk-screen
printed side (parts side) of the PWB diagrams, the parts that are
printed over with black such as the resistor ( ), diode ( )
and ICP ( ) or identified by the " " mark nearby are critical
for safety. When replacing them, be sure to use the parts of the
same type and rating as specified by the manufacturer.
(This regulation dose not Except the J and C version)
each exposed
metal part.
(No.MA526<Rev.001>)5/16