JVC KD-A95BTJ, KD-R90BTE, KD-R90BTEN, KD-R90BTEY, KD-R90BTU Service manual

...
SERVICE MANUAL
CD RECEIVER
MA526<Rev.001>20123SERVICE MANUAL
KD-A95BTJ, KD-R90BTE,
KD-R90BTEN, KD-R90BTEY,
DETACH PANEL
Model Parts number KD-R90BTE KD-R90BTEY KD-R90BTEN KD-R90BTU KD-R90BTUN KD-A95BTJ
For Europe
CP-R90BTED CP-R90BTED CP-R90BTED CP-R90BTUD CP-R90BTUD CP-A95BTJD
For US
COPYRIGHT © 2012 JVC KENWOOD Corporation
Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade) Lead free solder used in the board (material : Sn-Cu, melting point : 230 Centigrade)
COPYRIGHT © 2012 JVC KENWOOD Corporation
For
EY
No.MA526<Rev.001>
2012/3
SPECIFICATION
For US
AUDIO AMPLIFIER SECTION
Power Output 20 W RMS x 4 Channels at 4 and
Load Impedance 4 (4 Ω to 8 Ω allowance)
Frequency Response 40 Hz to 20 000 Hz
Signal-to-Noise Ratio 80 dBA (reference: 1 W into 4Ω)
Line-Out or Subwoofer-Out Level/Impedance 5 V/20 k load (full scale)
Output Impedance 600
TUNER SECTION
FM Frequency Range 200 kHz step: 87.9 MHz to 107.9 MHz
Usable Sensitivity 9.3 dBf (0.8 µV/75Ω)
50 dB Quieting Sensitivity 16.3 dBf (1.8 µV/75Ω)
Alternate Channel Selectivity (400 kHz) 65 dB
Frequency Response 40 Hz to 15 000 Hz
Stereo Separation 40 dB
AM Frequency Range 10 kHz step: 530 kHz to 1 700 kHz
Sensitivity/Selectivity 20 µV/40 dB
CD PLAYER SECTION
Signal Detection System Non-contact optical pickup (semiconductor laser)
Number of Channels 2 channels (stereo)
Frequency Response 5 Hz to 20 000 Hz
Signal-to-Noise Ratio 102 dB
Wow and Flutter Less than measurable limit
USB SECTION
USB Standard USB 1.1, USB 2.0
Data Transfer Rate (Full Speed) Max. 12 Mbps
Compatible Device Mass storage class
Compatible File System FAT 32/16/12
Playable Audio Format MP3/WMA/WAV
Maximum Supply Current DC 5 V 1 A
BLUETOOTH SECTION
Version Bluetooth 2.1 certified (+EDR)
Power Class Class 2 Radio
Service Area 10 m (10.9 yd)
Profile HFP 1.5, OPP 1.1, A2DP 1.2, AVRCP 1.3, PBAP 1.0
GENERAL
Power Requirement (Operating Voltage) DC 14.4 V (11 V to 16 V allowance)
Grounding System Negative ground
Allowable Operating Temperature 0°C to +40°C (32°F to 104°F)
Dimensions (W × H × D)(approx.)
Mass 1.4 kg (3.1 lbs) (excluding accessories)
Subject to change without notice.
Installation Size 182 mm × 52 mm × 159 mm (7-3/16" × 2-1/16" × 6-5/16")
Panel Size 188 mm × 59 mm × 13 mm (7-7/16" × 2-3/8" × 9/16")
50 kHz step: 87.5 MHz to 108.0 MHz
9 kHz step: 531 kHz to 1 611 kHz
1% THD+N
(No.MA526<Rev.001>)2/16
For ASIA
AUDIO AMPLIFIER SECTION
Maximum Power Output 50 W per channel
Continuous Power Output (RMS) 20 W per channel into 4, 40 Hz to 20 000 Hz at less than 1% total harmonic distortion.
Load Impedance 4 (4 to 8 allowance)
Frequency Response 40 Hz to 20 000 Hz
Signal-to-Noise Ratio 80 dB
Line-Out or Subwoofer-Out Level/Impedance 5 V/20 k load (full scale)
Output Impedance 600
TUNER SECTION
FM Frequency Range 87.5 MHz to 108.0 MHz
Usable Sensitivity 9.3 dBf (0.8 µV/75Ω)
50 dB Quieting Sensitivity 16.3 dBf (1.8 µV/75Ω)
Alternate Channel Selectivity (400 kHz) 65 dB
Frequency Response 40 Hz to 15 000 Hz
Stereo Separation 40 dB
AM Frequency Range 531 kHz to 1 611 kHz
Sensitivity/Selectivity
CD PLAYER SECTION
Signal Detection System Non-contact optical pickup (semiconductor laser)
Number of Channels 2 channels (stereo)
Frequency Response 5 Hz to 20 000 Hz
Signal-to-Noise Ratio 102 dB
Wow and Flutter Less than measurable limit
USB SECTION
USB Standard USB 1.1, USB 2.0
Data Transfer Rate (Full Speed) Max. 12 Mbps
Compatible Device Mass storage class
Compatible File System FAT 32/16/12
Playable Audio Format MP3/WMA/WAV
Maximum Supply Current DC 5 V 1 A
BLUETOOTH SECTION
Version Bluetooth 2.1 certified (+EDR)
Power Class Class 2 Radio
Service Area 10 m
Profile HFP 1.5, OPP 1.1, A2DP 1.2, AVRCP 1.3, PBAP 1.0
GENERAL
Power Requirement (Operating Voltage) DC 14.4 V (11 V to 16 V allowance)
Grounding System Negative ground
Allowable Operating Temperature 0°C to +40°C
Dimensions (W × H × D)
Mass 1.4 kg (excluding accessories)
Installation Size approx. 182 mm × 52 mm × 159 mm
Panel Size approx. 188 mm × 59 mm × 13 mm
20
µV/40 dB
Subject to change without notice.
(No.MA526<Rev.001>)3/16
For Europe
AUDIO AMPLIFIER SECTION
Maximum Power Output 50 W per channel
Continuous Power Output (RMS) 20 W per channel into 4, 40 Hz to 20 000 Hz at less than 1% total harmonic distortion.
Load Impedance 4 (4 Ω to 8 Ω allowance)
Frequency Response 40 Hz to 20 000 Hz
Signal-to-Noise Ratio 80 dB
Line-Out or Subwoofer-Out Level/Impedance 5 V/20 k load (full scale)
Output Impedance 600
TUNER SECTION
FM Frequency Range 87.5 MHz to 108.0 MHz
Usable Sensitivity 9.3 dBf (0.8 µV/75Ω)
50 dB Quieting Sensitivity 16.3 dBf (1.8 µV/75Ω)
Alternate Channel Selectivity (400 kHz) 65 dB
Frequency Response 40 Hz to 15 000 Hz
Stereo Separation 40 dB
AM Frequency Range MW: 531 kHz to 1 611 kHz
Sensitivity/Selectivity
CD PLAYER SECTION
Signal Detection System Non-contact optical pickup (semiconductor laser)
Number of Channels 2 channels (stereo)
Frequency Response 5 Hz to 20 000 Hz
Signal-to-Noise Ratio 102 dB
Wow and Flutter Less than measurable limit
USB SECTION
USB Standard USB 1.1, USB 2.0
Data Transfer Rate (Full Speed) Max. 12 Mbps
Compatible Device Mass storage class
Compatible File System FAT 32/16/12
Playable Audio Format MP3/WMA/WAV
Maximum Supply Current DC 5 V 1 A
BLUETOOTH SECTION
Version Bluetooth 2.1 certified (+EDR)
Power Class Class 2 Radio
Service Area 10 m
Profile HFP 1.5, OPP 1.1, A2DP 1.2, AVRCP 1.3, PBAP 1.0
GENERAL
Power Requirement (Operating Voltage) DC 14.4 V (11 V to 16 V allowance)
Grounding System Negative ground
Allowable Operating Temperature 0°C to +40°C
Dimensions (W × H × D)
Mass 1.4 kg (excluding accessories)
Installation Size approx. 182 mm × 52 mm × 159 mm
Panel Size approx. 188 mm × 59 mm × 13 mm
LW: 153 kHz to 279 kHz
MW: 20
µV/40 dB, LW: 50 µV
Subject to change without notice.
(No.MA526<Rev.001>)4/16
SECTION 1
PRECAUTION

1.1 Safety Precautions

(1) This design of this product contains special hardware and
many circuits and components specially for safety purpos­es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per­formed by qualified personnel only.
(2) Alterations of the design or circuitry of the product should
not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteris­tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us­ing replacement components rated for higher voltage, watt­age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser­vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac­teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.
(4) The leads in the products are routed and dressed with ties,
clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem­bling.
(5) Leakage shock hazard testing
After reassembling the product, always perform an isola­tion check on the exposed metal parts of the product (an­tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check.
• Plug the AC line cord directly into the AC outlet. Using a "Leakage Current Tester", measure the leakage current from each exposed metal parts of the cabinet, particular­ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur­rent must not exceed 0.5mA AC (r.m.s.).
• Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000Ω per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15µF AC-type capacitor between an ex­posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC
voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.).
AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity)
0.15 F AC TYPE
Place this probe on
1500 10W
Good earth ground

1.2 Warning

(1) This equipment has been designed and manufactured to
meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that
these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant
safety standards.
(4) It is essential that safety critical components are replaced
by approved parts.
(5) If mains voltage selector is provided, check setting for local
voltage.

1.3 Caution

Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pre­forming repair of this system.

1.4 Critical parts for safety

In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the " " mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)
each exposed metal part.
(No.MA526<Rev.001>)5/16