Jenn-Air JDS8850CDB00, JDS8850CDB01, JDS8850CDR00, JDS8850CDS00, JDS8850CDS01 Installation Guide

...
_]ENN-AIRo
INSTALLATIONINSTRUCTIONS
30" (76.2 CM) SLIDE-INDUALFUELRANGES
INSTRUCTIONSPOURL'INSTALLATIONDESCUISINIERES
A BI-COMBUSTIBLEENCASTRABLESDE30" (76,2 CM)
Table of Contents Table des mati_res
RANGE SAFETY ........................................................ 2
INSTALLATION REQUIREMENTS ........................... 3
Tools and Parts ....................................................... 3
Electrical Requirements - U.S.A. Only ................... 5
Electrical Requirements - Canada Only ................. 5
Countertop Preparation .......................................... 7
INSTALLATION INSTRUCTIONS ............................. 7
Unpack Range ........................................................ 7
Adjust Leveling Legs ............................................... 8
Make Gas Connection .......................................... 11
Verify Anti-Tip Bracket Location ........................... 11
Level Range .......................................................... 12
Electronic Ignition System .................................... 12
Complete Installation ............................................ 13
GAS CONVERSIONS ............................................... 13
LP Gas Conversion ............................................... 13
Natural Gas Conversion ....................................... 15
SI_CURITI_ DE LA CUISINII_RE ....................................... 17
EXIGENCES D'INSTALLATION ....................................... 19
Outillage et pieces ......................................................... 19
Exigences d'emplacement ............................................ 19
Sp6cifications 61ectriques- Canada uniquement ......... 21
Sp6cifications de I'alimentation en gaz......................... 21
Preparation du plan de travail ........................................ 22
INSTRUCTIONS D'INSTALLATION ................................ 23
Deballage de la cuisiniere .............................................. 23
R6glage des pieds de nivellement ................................. 23
Installation de la bride antibasculement ........................ 24
Raccordement au gaz .................................................... 24
Verification de I'emplacement de la
bride antibasculement ................................................... 25
R6glage de I'aplomb de la cuisiniere ............................. 26
Systeme d'allumage 61ectronique ................................. 26
Achever I'installation ...................................................... 27
CONVERSIONS POUR CHANGEMENT DE GAZ ........... 27
Conversion pour I'alimentation au propane .................. 27
Conversion pour I'alimentation au gaz naturel .............. 29
iMPORTANT:
installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
iMPORTANT :
Instaiiateur : Remettre les instructions d'installation au propri6taire.
Propri6taire : Conserver les instructions d'installation pour r6f6rence ult6rieure.
W10253460A
RANGE SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death,
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier,
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA. For more information, contact your gas supplier. If a gas leak is detected, follow the "What to do if you smell gas" instructions.
In the State of Massachusetts, the following installation instructions apply: [] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T-handle type. [] A flexible gas connector, when used, must not exceed 3 feet.
2
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults.
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Tools needed
Tape measure Pipe-joint compound
Phillips screwdriver
Flat-blade screwdriver 3/16"(4.8 mm) carbide-tipped
1/8"flat-blade screwdriver concrete/ceramic floors)
Level Noncorrosive leak-detection
Hand or electric drill
Wrench or pliers Conversions
Pipe wrench 1/2"combination wrench
1%6"combination wrench 1¼,,(6 mm) nut driver
1/8"(3.2 mm) drill bit (for 9/32"(7 mm) nut driver wood floors)
Marker or pencil
Parts supplied
Check that all parts are included.
LP/Natural Gas Conversion Kit (taped on regulator support at back of range)
5- Burner caps
2- Burner grates
3- Oven racks
2 - #12 x 15/8'' screws (for mounting anti-tip bracket)
1 - Metal ground strap (for 3-wire connection)
Anti-tip bracket (taped to package containing literature) Anti-tip bracket must be securely mounted to the back wall or
floor. Thickness of flooring may require longer screws to anchor bracket to subfloor. Longer screws are available from your local hardware store.
resistant to LP gas
masonry drill bit (for
solution
For LP/Natural Gas
Masking tape
IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air.
It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the storage drawer
on the right-hand side of the oven frame. The range should be located for convenient use in the kitchen. Recessed installations must provide complete enclosure of
the sides and rear of the range. To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood or
microwave hood combination that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
All openings in the wall or floor where range is to be installed must be sealed.
Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti- tip bracket shipped with the range, see "Install Anti-Tip Bracket" section.
Grounded electrical supply is required. See "Electrical Requirements" section.
Proper gas supply connection must be available. See "Gas Supply Requirements" section.
Contact a qualified floor covering installer to check that the floor covering can withstand at least 200°F (93°C).
Use an insulated pad or 1¼.(0.64 cm) plywood under range if installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Parts needed
Check local codes and consult gas supplier. Check existing gas supply and electrical supply. See "Electrical Requirements" and
"Gas Supply Requirements" sections.
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the current standards CAN/CSA-A240-1atest edition, or with local
codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the
range is adequate as long as it conforms to the standards listed above.
Product Dimensions
A
B
D
F
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height. IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or microwave hood combination installation instructions for
dimensional clearances above the cooktop surface. Range may be installed with zero clearance to combustible
construction at the rear and on the sides below the cooktop.
F
A. 303/4" (78.1 cm) B. 353/4'' (90.8 cm) height to underside
of cooktop edge with levering legs screwed aft the way in*
C. Model/serial number plate (located
behind the storage drawer on the right-hand side of the oven frame)
297/8" (75.9 cm)
Gas information plate (located behind the warming drawer on the
left-hand side of oven
frame)
E
291/16'' (73.8 cm) from handle to back of range**
G.
23V2" (59.7 cm)
countertop notch to rear
of cooktop
*Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
**When installed in a 24" (61.0 cm) base cabinet with
25" (63.5 cm) countertop; front of oven door protrudes 21/2'' (6.4 cm) beyond 24" (61.0 cm) base cabinet.
A. 13" (33.0 cm) upper cabinet depth B. 30" (76.2 cm) min. opening width C. For minimum clearance to the top of the cooktop, see NOTE. D. 231/4''(59.1 cm) opening depth E. 30" (76.2 cm) min. opening width
F. Electrical and gas supply - 5V2" (14.0 cm) min. from either cabinet,
10" (25.4 cm) max. from floor. Nothing located in shaded area can extend more than 2¼" (5.7 cm) from back wall or range will not slide all the way back. Grounded outlet must be flush mounted.
G. Cabinet door or hinge should not extend into cutout.
H. 18" (45.7 cm)
I. 3" (7.6 cm) min. clearance from both sides of the range to the side
wall or other combustible material.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is shielded by not less than 1/4"(0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
Theelectricalconnectiontothisrangeisdesignedonlyforuse withaflexiblepowercord.Allrangesareshippedwithaspecially designed4-wirepowersupplycord.Thiscordshouldbeusedon
allnewbranchcircuits,mobilehomesandwhenlocalcodes prohibitgroundingthoughtheneutral.Fora3-wirepowersupply
cordreplacement,servicekitpartnumber74011285mustbe used.
Ifcodespermitandaseparategroundwireisused,itis recommendedthataqualifiedelectricalinstallerdeterminethat thegroundpathandwiregaugeareinaccordancewithlocal
codes. Donotuseanextensioncord.
Besurethattheelectricalconnectionandwiresizeareadequate andinconformancewiththeNationalElectricalCode,ANSI/NFPA
70-latesteditionandalllocalcodesandordinances. Acopyoftheabovecodestandardscanbeobtainedfrom:
NationalFireProtectionAssociation OneBatterymarchPark
Quincy,MA02269. WARNING:Improperconnectionoftheequipment-grounding
conductorcanresultinariskofelectricshock.Checkwitha qualifiedelectricianorservicetechnicianifyouareindoubtasto whethertheapplianceisproperlygrounded.Donotmodifythe
powersupplycordplug.Ifitwillnotfittheoutlet,haveaproper outletinstalledbyaqualifiedelectrician.
Electrical Connection
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions
provided for it here.
Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located behind the control panel or on the oven frame behind the storage drawer panel. Refer to the figures in the "Product Dimensions" section of the "Location Requirements" section.
This range is manufactured with a 4-wire 40-amp power cord. For a 3-wire connection order UL listed power cord Part
Number 74011285.
When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power
supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50P plug on the
supply end.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power
cord are: 40-amp circuit
2 No.-8 conductors 1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40- or 50-amp range power supply cord (pigtail). Order UL listed 3-wire power cord part number 74011285. This cord contains 3
copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors onthe appliance end must be provided at the point the power supply cord enters the appliance.
This uses a 3-wire receptacle of NEMA Type 10-50R. For a 3-wire
power supply cord replacement, service kit part number 74011285 must be used.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW 7.8 - 12.5 KW 40 or 50**
16.6 - 22.5 KW 12.6 - 18.5 KW 50
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 13/8'' (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
Wire sizes and connections must conform with the rating of the range.
The wiring diagram is located at the back of the warming drawer.
If connecting to a 4-wire system:
The green ground wire of the 4-wire power supply cord must be connected to the cabinet. See "Electrical Connection."
Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.
3-wire receptacle (10-50R)
Electrical Shock Hazard
Electrically ground range. Failure to do so can result in death, fire, or
electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance with local codes.
Be sure that the electrical connection and wire size are adequate and in conformance with CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local codes and ordinances.
Acopyoftheabovecodestandardscanbeobtainedfrom:
CanadianStandardsAssociation
178RexdaleBlvd.
Toronto,ONM9W1R3CANADA
Checkwithaqualifiedelectricalinstallerifyouarenotsurethe rangeisproperlygrounded.
RangeRating* Ratingof Circuit
Power Protection
Supply Cord
120/240 Volts 120/208 Volts Amps Amps
8.8 - 16.5 KW 7.8 - 12.5 KW 40 40 or 50
16.6 - 22.5 12.6 - 18.5 50 50 KW KW
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
A time-delay fuse or circuit breaker is recommended. This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
Do not use an extension cord.
IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest edition.
IMPORTANT: Leak testing of the range must be conducted according to the manufacturer's instructions.
Type of Gas
Natural gas:
This range is design-certified by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. See "Gas Conversions" section. The gas information plate located behind the warming drawer on the left-hand side of front
frame has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See "Gas
Conversions" section.
Gas Supply Line
Provide a gas supply line of 3_,,(1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can
be 1/2"(1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON ®ttape.
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, 1/2"(1.3 cm) or 3_,,(1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.
Explosion Hazard
Use a new CSA (nternational approved gas supply line. install a shut=off valve.
Securely tighten all gas connections. if connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
6
A 1/2"(1.3 cm) male pipe thread is needed for connection
to the female pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when
moving the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the range. The rigid pipe must be level with the range connection. All strains must be removed from the supply and fuel lines so range will be
level and in line.
1-®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Must include a shutoff valve: The supply line must be equipped with a manual shutoff valve.
This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be
in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or
shutting off gas to the range.
B
A
A. Gas supply line B. Shutoff valve "open" position C. Torange
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 1" water column pressure above the manifold pressure shown on
the model/serial rating plate.
Line pressure testing above 1/2psi gauge (14" WCP)
The range and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2psi (3.5 kPa).
Line pressure testing at 1/2psi gauge (14" WCP) or lower
The range must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2psi (3.5 kPa).
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:
Natural gas" Minimum pressure: 5" WCP
Maximum pressure: 14" WCP
LP gas:
Minimum pressure: 11" WCP Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet pressure.
Burner Input Requirements
Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ff (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level (not
applicable for Canada).
INSTALLATIONINSTRUCTIONS
The cooktop sides of the slide-in range fit over the cutout edge of your countertop.
If you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.
Formed front-edged countertops must have molded edge shaved flat 3/8"(1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back 3/8"(1.0 cm) from each
front corner and/or rounded edge flattened.
(78.1 crn)
If countertop opening width is greater than 30" (76.2 cm), adjust the 3/8"(1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to side, then front to back. Ifcountertop is not level, range will not be
level. Range must be level for satisfactory baking conditions.
(_]Y_b_GC( 4,_4Hti_3_c
Excessive Weight Hazard
Use two or more people to move and install range. Failure to do so can result in back or other injury.
1. Remove shipping materials, tape and film from the range. Keep cardboard bottom under range.
2. Remove oven racks and parts package from inside oven.
3. To remove cardboard bottom, place range on its back, take 4 cardboard corners from the carton. Stack one cardboard
corner on top of another. Repeat with the other 2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid on its back.
4. Using 2 or more people, firmly grasp the range and gently lay it on its back on the cardboard corners.
5. Pull cardboard bottom firmly to remove.
6. Use an adjustable wrench to loosen the leveling legs.
7. Place cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto cardboard or
hardboard.
_ ,@4 _ ......
.... _@<i<5
1,
If range height adjustment is necessary, use a wrench or pliers to loosen the 4 leveling legs.
This may be done with the range on its back or with the range supported on 2 legs after the range has been placed back to a
standing position. NOTE: To place range back up into a standing position, put a
sheet of cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto the cardboard or
hardboard.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti=tip bracket to rear range foot. Reconnect the anti=tip bracket, if the range is moved.
Failure to follow these instructions can result in death or serious burns to children and adults.
IIi*
A. Centerline B. 141/4'' (36.2 cm)
4. Drill two V8" (3 mm) holes that correspond to the bracket holes of the determined mounting method. See below.
Floor Mounting
A B
\
2,
Adjust the leveling legs to the correct height. Leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of 3Ad'(5 mm) is needed to engage the anti-tip bracket.
NOTE: If height adjustment is made when range is standing, tilt the range back to adjust the front legs, then tilt forward to
adjust the rear legs.
3,
When the range is at the correct height, check that there is adequate clearance under the range for the anti-tip bracket.
Before sliding range into its final location, check that the anti- tip bracket will slide under the range and onto the rear leveling leg prior to anti-tip bracket installation.
1,
Remove the anti-tip bracket that is taped to the package containing literature.
2.
Determine which mounting method to use: floor or wall. If you have a stone or masonry floor you can use the wall
mounting method.
3,
Determine and mark centerline of the cutout space. The mounting bracket can be installed on either the left side or
right side of the cutout. Position mounting bracket in cutout so that right (or left) edge of the bracket is 14V4" (36.2 cm) from centerline, as shown.
A. #12 x 1%" screws
B.Anti-tip bracket
Wall Mounting
A. #12 x 1%" screws B. Anti-tip bracket
5,
Using the Phillips screwdriver, mount anti-tip bracket to the wall or floor with the two #12 x 15/8"screws provided.
8
Power Supply Cord (optional)
This range is shipped with a specially designed 4-wire power
supply cord. This cord should be used on all new branch circuits, mobile homes and when local codes prohibit grounding though the neutral. For a 3-wire power supply cord replacement, service kit part number 74011285 must be used.
Electrical Shock Hazard
Disconnect power before servicing. Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death, fire, or electrical shock.
1=
Disconnect power.
2.
Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range. Pull cover down and
toward you to remove cover.
Tighten strain relief screw against the power supply cord.
Feed the flexible conduit through the strain relief, allowing enough slack to easily attach wiring to the terminal block.
Tighten strain relief screw against the flexible conduit.
Electrical Connection Options
If your home has: And you will be Go to Section:
connecting to:
4-wire receptacle A UL listed, 4-wire connection: (NEMA type 14-50R) 250-volt Power supply cord
minimum, power supply
40-amp, range
cord
3. Add strain relief.
Assemble a UL listed strain relief in the opening.
i x -
i ,_ !; j
.... J
Hi \ ............................
A. UL listed strain relief
Feed the power supply cord through the opening in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
3-wire receptacle A UL listed, (NEMA type 10-50R) 250-volt
3-wire connection: Power supply cord
minimum, power supply
40-amp, range
cord
4-wire connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the neutral
1=
Feed the power supply cord through the opening in the cord/ conduit plate on bottom of range. Allow enough slack to easily
attach the wiring to the terminal block.
A ..........__
B
;; .J ._-s _-¸
3-wire connection: Power Supply Cord (optional)
NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 13/8'' (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.
Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the opening in the cord/ conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
D
A. Terminalblock B.Ground-rink screw
C.Cord/conduit plate D.Power supply cord wires
2=
Use Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw. The ground wire must be attached first.
3=
Use 3/8"nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10-32 hex nuts.
F-
A F
S _
..... I
D
I , B ;
/
I
C
D
A. Terminal block B. Ground-link screw
C. Cord/conduit plate D. Power supply cord wires E. Metal ground strap
2=
Use 3/8"nut driver to connect the neutral (white) wire and copper ground strap provided to the center terminal block post with one of the 10-32 hex nuts. The opposite end of the
copper ground strap should be secured to the oven back with the green ground link-screw.
A. 10-32 hex nut B. Ground-link screw
C. Line 1 (black)
4=
Connect line 1 (black) and line 2 (red) wires to the outer
D. Green ground wire
E. Neutral (center) wire F. Line 2 (red)
terminal block posts with 10-32 hex nuts.
5.
Securely tighten hex nuts. NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 13/8'' (3.5 cm) diameter
connection opening, with ring terminals and marked for use with ranges. For a 3-wire power supply cord replacement, service kit part number 74011285 must be used.
6. Replace terminal block access cover.
10
E
B
c
A. 10-32 hex nut B. Line 1 (black)
C. Ground-rink screw
3. Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
5. Replace terminal block access cover.
D. Neutral (white) wire
E.Line 2 (red)
Loading...