ISO9001 - 2015 - Registered Firm Certificate No. GB 1552
LED Floodlights
Important warranty information
This product is supported by a 2-year standard warranty which will extend to 3 years if registered within the first year of purc
Please register at jcc.co.uk/warranty - Terms and conditions apply.
The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chas
Product Code/Date Code.
Installation guide for LED Floodlights
Warnings & Cautions
a
• To avoid electric shock, serious injury or property damage,
isolate power before installing, removing or servicing the product.
• It is recommended that luminaires are installed by a qualied
electrician to ensure the installation complies with the local
current wiring regulations.
• Any broken or damaged parts should be replaced as soon as possible.
• JCC will not accept responsibility for claims arising from
sub-standard installations; which will void the warranty.
• These products are designed for connection to a 220-240V~ 50/60Hz.
INSTALLATION
Specications Colour temp: 4000K Ra: 70
Total circuit
wattage
10W 1000 100
20W 2100 105
30W 2800 93
50W 4500 90
Beam angle: 110°
Available nishes: Black(BLK) or White(WH)
220-240V 50/60Hz / Class I
Figure 1. Mains input
Lumens LpcW
• The light source of this luminaire is not replaceable: When the light source reaches
the end of it’s life, the whole of the luminaire must be replaced.
• It may be necessary to upgrade your MCBs to allow for increased inrush current.
• Terminal block not included. Installation may require advice from a qualied person.
• Do not install in areas that are exposed to continual running water or prone
to ooding.
• Ensure that the mounting surface is both at and stable.
ENGLISH
• Read instructions and check that you have all of the tools and
accessories required to complete the installation correctly. Isolate
power supply before starting the installation.
Installation procedure
1. Prepare the mains input cable for termination. Note that this
product is class I and as such must be tted with an
earth connection.
2. Drill mounting holes and insert suitable wall plugs.
3. Rotate tting to access screw mounting points on the bracket and
secure using suitable xings..
4. Terminate input wiring to the tting as per Fig. 1 to the left using a
suitable IP rated connector.
5. Check seals, gaskets and the cable gland integrity before testing
the luminaire.
6. Turn on power supply and test for correct operation.
brown
Earth
yellow/green
Neutral (-)
blue
Wiring colours are for reference only
Terminal block must comply to EN 60998-2-1 or EN 60998-2-2
LED
Non-replaceable light source
Replaceable control gear
by a professional
LED
General Maintenance Requirements
This product has no user servicable parts. JCC Lighting Products would recommend
that the following maintenance is performed in order to prolong the life of this
product: Clean with a damp cloth and dry with a lint free cloth or kitchen towel.
Do not use abrasive cleaners.
Prole & Dimensions
All dimensions in millimetres
10W
131.4mm 26.5mm
20W
50W
231.2mm 32.3mm
30W
177.5mm
184.2mm 28.3mm
RoHS
Compliant
JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, PO20 2FT
IP65
Technical Support: +44(0)1243 838986 Customer Services: +44(0)1243 838999
jcc.co.uk
sis:
214.1mm 30.4mm
hase.
V3_May_2022_RS