Dispose of the unit and used batteries in an environment friendly manner
according to your country regulations.
FR - DÉCLASSER L’APPAREIL
Débarrassez-vous de l’appareil et des piles usagées de manière écologique
Conformément aux dispositions légales de votre pays.
NL - VERWIJDEREN VAN HET APPARAAT
Verwijder het toestel en de gebruikte batterijen op een milieuvriendelijke
manier conform de in uw land geldende voorschriften.
DU - ENTSORGUNG DES GERÄTS
Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und
Weise gemäß den Vorschriften Ihres Landes.
ES - DESHACERSE DEL APARATO
Reciclar el aparato y pilas usadas de forma ecologica conforme a las
disposiciones legales de su pais.
PT - COMO DESFAZER-SE DA UNIDADE
Tente reciclar a unidade e as pilhas usadas respeitando o ambiente e em
conformidade com as normas vigentes no seu país.
ENGLISH OPERATION MANUAL
ENGLISH OPERATION MANUAL
CAUTIONS REGARDING HANDLING
Thank you for buying this JB Systems product. To take full advantage of all
possibilities, please read these operating instructions very carefully.
FEATURES
This unit is radio-interference suppressed. This product meets the requirements of the
current European and national guidelines. Conformity has been established and the
relevant statements and documents have been deposited by the manufacturer.
• 6 channel Dimmer + Switch pack
• Max load 10A per channel with automatic 10A circuit breakers
• DMX and analog 0/10V inputs
• Block or individual channel addressing (soft patch)
• Overall or individual channel switch/dimmer mode (linear or square curve)
• Overall or individual channel presets 0-100% (no control panel needed)
• Overall or individual channel preheats 0-50%
• DMX-failure: auto DMX-hold, auto analog 0/10V or auto built-in patterns
• Phase Correction for linear dimming curves
• LCD display with channel output indications
• 3-Phase and single phase 230Vac 50~60Hz inputs
• Power failure memory
BEFORE USE
Check the contents:
Check that the carton contains the following items:
• DSP6 dimmer/switch pack
• Operating instructions
Some important instructions:
• Before you start using this unit, please check if there’s no transportation damage.
Should there be any, do not use the device and consult your dealer first.
•
Important:
absolutely necessary for the user to strictly follow the safety instructions and
warnings in this user manual. Any damage caused by mishandling is not subject to
warranty. The dealer will not accept responsibility for any resulting defects or
problems caused by disregarding this user manual.
• Keep this booklet in a safe place for future consultation. If you sell the fixture, be
sure to add this user manual.
• To protect the environment, please try to recycle the packing material as much as
possible.
JB SYSTEMS® 1/55 DSP6
This device left our factory in perfect condition and well packaged. It is
• To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
• To avoid condensation to be formed inside, allow the unit to adapt to the surrounding
temperatures when bringing it into a warm room after transport. Condense
sometimes prevents the unit from working at full performance or may even cause
damages.
• This unit is for indoor use only.
• Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction
may result. If a foreign object enters the unit, immediately disconnect the mains
power.
• Don’t cover any ventilation openings as this may result in overheating.
• Prevent use in dusty environments and clean the unit regularly.
• Keep the unit away from children.
• Inexperienced persons should not operate this device.
• Maximum save ambient temperature is 45°C. Don’t use this unit at higher ambient
temperatures.
• Always unplug the unit when it is not used for a longer time or before you start
servicing.
• The electrical installation should be carried out by qualified personal only, according
to the regulations for electrical and mechanical safety in your country.
• Check that the available voltage is not higher than the one stated on the rear panel
of the unit.
• The power cord should always be in perfect condition: switch the unit immediately off
when the power cord is squashed or damaged.
• Never let the power-cord come into contact with other cables!
• This appliance must be earthed to in order comply with safety regulations.
• Don’t connect the unit to any dimmer pack.
• In order to prevent electric shock, do not open the cover. Apart from mains fuse
there are no user serviceable parts inside.
•
Never
a fuse of the same type and electrical specifications!
• In the event of serious operating problems, stop using the appliance and contact
your dealer immediately.
• Please use the original packing when the device is to be transported.
• Due to safety reasons it is prohibited to make unauthorized modifications to the unit.
JB SYSTEMS® 2/55 DSP6
CAUTION
The lightning flash with arrowhead symbol within the equilateral triangle is
intended to alert the use or the presence of un-insulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the
user to the presence of important operation and maintenance (servicing)
instructions in the literature accompanying this appliance.
repair a fuse or bypass the fuse holder.
CAUTION: To reduce the risk of electric shock,
do not remove the top cover. No userserviceable parts inside. Refer servicing to
qualified service personnel only.
replace a damaged fuse with
Always
ENGLISH OPERATION MANUAL
MAINTENANCE
Clean by wiping with a polished cloth slightly dipped with water. Avoid getting water
inside the unit. Do not use volatile liquids such as benzene or thinner which will
damage the unit.
FRONT PANEL
ENGLISH OPERATION MANUAL
9. CIRCUIT BREAKERS: In case of a short circuit these circuit breakers switch off to
protect the output stages of the DSP6. After inspection of the installation you can
switch them back on. In normal working condition these circuit breakers are always
switched on.
REAR PANEL
1. DMX LED: Blinks when a DMX signal is detected.
2. LCD DISPLAY: monitors the current output states of the channels and helps the
user with the setup of the different menus.
In normal working condition the display shows the output states of the channels
(see picture): The screen shows 6 channels. Above each channel there’s a bar
indicating the dimming level of that channel. The first digit shows the name of the
channel that has been last modified. (in the picture the dimming value of channel 6
was the last modified)
3. MENU Button: Used to access the different setup menus. See “Setup menus” for
more information.
4. UP Button: Used to scroll the menus or to increase the values.
5. DOWN Button: Used to scroll the menus or to decrease the values.
6. ESC Button: Used to go one step back in the menu level or to leave the menu
system.
7. CHANNEL BUTTONS: The DSP6 can work without a controller for the input
signals. This is a good option if you just need a certain output level on each
channel over a long time (shops, exhibition booths, pubs etc…) Just press and
hold the channel button of the channel you want to edit. While you keep the
channel button pressed you can use the “up/down” buttons to change the output
level of that channel.
8. CHANNEL INDICATORS: In addition to the LCD display these leds show the
output condition of the channels.
10. DMX INPUT: male XLR-connector used to connect the DSP6 to a DMX controller
or any other DMX unit in the chain.
DMX OUTPUT: female XLR-connector used to connect the DSP6 to the next unit
in the DMX chain.
11. ANALOG UE I NPUT S: 8pin DIN connector used for the analogue
0~10Vdc inputs. Refer to the picture on the right for the pinning of
the connector.
Attention: The analogue input only works when the “DMX fail” option is set to
“Analog” and no DMX-signal is connected to the DSP6 (DMX led is off)
12. CHANNEL OUTPUTS: Each of the 6 channels have 2 output
wires. While connecting please pay attention to the “L” and “N” indications on the
back panel.
13. EARTH WIRE CONNECTIONS: Make sure to earth the DSP6 properly!
14. NEUTRAL INPUT WIRES: Neutral input wires. These 3 connectors are linked
together on the inside of the DSP6.
15. PHASE INPUTS: The DSP6 can be connected in single phase or 3phase. Refer to
the next chapter for proper connection.
JB SYSTEMS® 3/55 DSP6
JB SYSTEMS® 4/55 DSP6
ENGLISH OPERATION MANUAL
ENGLISH OPERATION MANUAL
CONNECTIONS
This unit may only be installed by qualified personal, following the
rules for electrical installations in your country! After installation
always put the metal covers back in place and make sure to use
proper cable entry glands (see picture) to protect the wires from
unwanted traction and friction.
• SINGLE PHASE INSTALLATION (2 wires “L”+“N”+ earth wire “E”):
• Since you have only 1 phase wire (L) you must make bridges between the
L1/L2/L3 inputs and connect the phase wire to these inputs.
• Connect the neutral (N) to the N-input.
• Connect the loads to the output channels (2 connections, named “L” and “N”) All
connections named “N” are linked inside the DSP6.
• Don’t forget to connect the earth connection properly!
• THREE PHASE INSTALLATION (4wires “L1+L2+L3+N” + earth wire “E”):
• Since you have 3 phase wires you can connect these directly to the corresponding
L1/L2/L3 inputs.
• Connect the neutral (N) to the N-input.
• Connect the loads to the output channels (2 connections, named “L” and “N”) All
connections named “N” are linked inside the DSP6.
• Don’t forget to connect the earth connection properly!
SETUP MENUS
Please refer to the overview below to fully understand the menu structure of the DSP6:
You can clearly see which buttons to push to select a certain function. In most cases
the DSP6 is in normal working condition (display shows channel output condition).
Push the “menu” button to enter the setup menus. With the “up/down” buttons you can
scroll through the 5 available menus. With the “esc” button you can go one step back
in the menu. After +/-30sec the DSP6 returns automatically to the normal working
mode.
In the next chapter you can read more about each function.
JB SYSTEMS® 5/55 DSP6
JB SYSTEMS® 6/55 DSP6
ENGLISH OPERATION MANUAL
ENGLISH OPERATION MANUAL
MENU ITEMS
•DMX FAIL:
The DSP6 works with analog 0/10V or digital DMX-512 input signals. DMX-signals
have priority to the analog inputs. This means that you can only use the analog
inputs when no DMX-signal is detected. When the DMX-signal is not present you
have 3 options:
•Hold:
In case of DMX-fail the DSP6 keeps the last scene on the outputs.
• Press “menu” and “up/down” until the display shows “Dmx fail”.
• Press “menu” again: the display shows one of the 3 options.
• Press “up/down” until the display shows “Hold”
• Press “esc” to store this option and leave the menu.
• Analog:
In case of DMX-fail the DSP6 goes in analog 0/10V mode.
•Prog 01 … Prog 12:
In case of DMX-fail the DSP6 shows one of the 12 built-in patterns.
• Press “menu” and “up/down” until the display shows “Dmx fail”.
• Press “menu” again: the display shows one of the 3 options.
• Press “up/down” until the display shows “Analog”
• Press “esc” to store this option and leave the menu.
• Press “menu” and “up/down” until the display shows “Dmx fail”.
• Press “menu” again: the display shows one of the 3 options.
• Press “up/down” until the display shows the desired program (Prog 01 … 12)
• Press “esc” and “up/down” buttons to select the proper speed.
• Press “esc” to store the selected speed and leave the menu.
• CURVE:
With the DSP6 you can select a different working mode (curve) for each individual
channel. This is a nice feature if you need to switch light effects on/off while at the
same time you have to dim lamps. 3 Curves are available:
• Select a curve for all channels:
• Press “menu” and “up/down” until the display shows “Curve”.
• Press “menu” again: the display shows one of the 2 options.
• Press “up/down” until the display shows “All”
• Press “menu” to select this option.
JB SYSTEMS® 7/55 DSP6
• Select a curve for individual channels:
• PREHEAT:
On the DSP6 you can set a preheat level up to 50% for all channels in one time or
for each channel separately. While the preheat function keeps the lamp filament at a
certain temperature, the turn on current of the lamp is much lower. This extends the
lamp life considerably in many cases.
• Preheat on all channels:
• Preheat on individual channels:
• DMX ADDRESSING:
On the DSP6 you can set the DMX start address for the complete unit or for each
channel separately. Due to this “soft patch” option DMX addressing becomes
extremely flexible.
• Setting the start address for the complete unit:
• Setting the start address for individual channels:
JB SYSTEMS® 8/55 DSP6
• Press “up/down” to select one the 3 curves
• Press “esc” to store the selected curve and leave the menu.
• Press “menu” and “up/down” until the display shows “Curve”.
• Press “menu” again: the display shows one of the 2 options.
• Press “up/down” until the display shows “Single”
• Press “menu” to select this option: the display shows the channel number on
the first row and the curve on the second row.
• Press “menu” to toggle between both rows.
• Press “up/down” to set the desired curves and channel numbers until all
channels are set.
• Press “esc” to store the selected curves and leave the menu.
• Press “menu” and “up/down” until the display shows “Preheat”.
• Press “menu” again: the display shows one of the 2 options.
• Press “up/down” until the display shows “All”
• Press “menu” to select this option.
• Press “up/down” to set the desired overall level.
• Press “esc” to store the selected level and leave the menu.
• Press “menu” and “up/down” until the display shows “Preheat”.
• Press “menu” again: the display shows one of the 2 options.
• Press “up/down” until the display shows “Single”
• Press “menu” to select this option: the display shows the channel number on
the first row and the preheat level on the second row.
• Press “menu” to toggle between both rows.
• Press “up/down” to set the desired preheat levels and channel numbers until all
channels are set.
• Press “esc” to store the selected preheat levels and leave the menu.
• Press “menu” and “up/down” until the display shows “Dmx addr”
• Press “menu” again: the display shows one of the 2 options.
• Press “up/down” until the display shows “Block”
• Press “menu” to select this option.
• Press “up/down” to set the desired start address for the DSP6.
• Press “esc” to store the selected level and leave the menu.
ENGLISH OPERATION MANUAL
• Press “menu” and “up/down” until the display shows “Dmx addr”
• Press “menu” again: the display shows one of the 2 options.
• Press “up/down” until the display shows “Single”
• Press “menu” to select this option: the display shows the channel number on
the first row and the DMX address on the second row.
• Press “menu” to toggle between both rows.
• Press “up/down” to set the desired DMX addresses and channel numbers until
all channels are set.
• Press “esc” to store the selected DMX addresses and leave the menu.
• PHASE CORRECTION:
To be able to produce perfectly linear curves the DSP6 has phase correction on
board. Normally this option should always be switched on. However some control
desks have built-in phase correction that can’t be switched off. In these cases the
phase correction of the DSP6 can be switched off.
• Switching phase correction on/off:
• Press “menu” and “up/down” until the display shows “Pha corr”
• Press “menu” again: the display shows one of the 2 options (on/off)
• Press “up/down” until the display shows the desired option.
• Press “esc” to store the selected option and leave the menu.
SPECIFICATIONS
Power Input: Single Phase 230Vac 50~60Hz (2 wires)
Three Phase 230Vac 50~60Hz (4 wires)
Power outputs: Max. 6x 10A (max.10A per channel)
DMX-512 in/out: in: male 3pin XLR ~ out: female 3pin XLR
Analog input: DIN 8pin connector: 0~10Vdc
Size (WxHxD): 483 x 88 x 420mm
Weight: 9kg
Every information is subject to change without prior notice
FRANCAIS MODE D’EMPLOI
Nous vous remercions d’avoir acheté ce produit JB Systems. Veuillez lire ce mode
d’emploi très attentivement afin de pouvoir exploiter toutes les possibilités de cet
appareil.
CARACTERISTIQUES
Cet appareil ne produit pas d’interférences radio. Il répond aux exigences nationales
et européennes. La conformité a été établie et les déclarations et documents
correspondants ont été déposés par le fabricant.
• Dimmer + Switch pack à 6 canaux
• Charge maximale de 10A par canal avec disjoncteurs automatiques de 10A
• Entrée DMX et analogique 0/10V
• Fonction switch/dimmer, par canal individuel ou en bloc (courbe linéaire ou carrée)
• Adressage individuel des canaux ou en bloc (soft patch)
• Programmation individuelle des canaux ou de l’unité complète en bloc, de 0-100%
(ne nécessite pas de panneau de contrôle)
• Préchauffe individuel des canaux ou en bloc, de 0-50%
• En cas d’absence de signaux DMX: passage automatique en DMX-hold, en 0/10V
ou au déroulement automatique des programmes internes
• Construction modulaire: très facile à l’entretien!
• Correction de phase pour des courbes de gradation linéaires
• Ecran LCD affichant l’état de sortie de chaque canal
• Entrées monophasés ou triphasés 230Vac 50~60Hz
• Mémoire anti-panne de courant
JB SYSTEMS® 9/55 DSP6
AVANT L’UTILISATION
Vérifiez le contenu:
Vérifiez si la boite contient les articles suivants :
• DSP6 dimmer/switch pack
• Mode d’emploi
Quelques instructions importantes:
• Avant d’utiliser cet appareil, assurez-vous de l’absence de dommage lié au
transport. En cas d’endommagement, n’utilisez pas l’appareil et contactez le
vendeur.
•Important: Cet appareil a quitté notre usine en parfaite condition et bien emballé. Il
est primordial que l’utilisateur suive les instructions de sécurité et avertissements
inclus dans ce manuel. La garantie ne s’applique pas en cas de dommage lié à une
utilisation incorrecte. Le vendeur ne prend pas la responsabilité des défauts ou de
JB SYSTEMS® 10/55 DSP6
FRANCAIS MODE D’EMPLOI
tout problème résultant du fait de n’avoir pas tenu compte des mises en garde de ce
manuel.
• Conservez ce manuel dans un endroit sûr pour toute consultation future. Si vous
vendez l’appareil, assurez-vous d’y joindre ce manuel également.
• Afin de protéger l’environnement, merci de recycler les emballages autant que
possible.
INSTRUCTIONS DE SECURITE:
CAUTION
même. Confiez l’entretien uniquement aux techniciens qualifiés.
Cette flèche dans un triangle met l'utilisateur en garde de la présence de
haut voltage sans isolation dans l'appareil qui peut causer un risque
d'électrocution.
Un point d'exclamation dans un triangle prévient de la présence d'instructions
de fonctionnement et de maintenance se trouvant dans le manuel, fourni avec
l'appareil.
• Afin d’éviter tout risque d’incendie ou de choc électrique, ne pas exposer cet appareil
à la pluie ou l’humidité.
• Pour éviter la formation de condensation à l’intérieur de l’appareil, patientez
quelques minutes pour laisser l’appareil s’adapter à la température ambiante lorsqu’il
arrive dans une pièce chauffée après le transport. La condensation empêche l’unité
de fonctionner en performance optimale et peut même causer des dommages.
• Cette unité est destinée à une utilisation à l’intérieur uniquement.
• Ne pas insérer d’objet métallique ou verser un liquide dans l’appareil. Risque de
choc électrique ou de dysfonctionnement. Si un corps étranger est introduit dans
l’unité, déconnectez immédiatement de la source d’alimentation.
• Ne pas couvrir les ouvertures de ventilation, un risque de surchauffe en résulterait.
• Ne pas utiliser dans un environnement poussiéreux et nettoyez l’unité régulièrement.
• Ne pas laisser l’unité à portée des enfants.
• Les personnes non expérimentées ne doivent pas utiliser cet appareil.
• La température ambiante maximum d’utilisation de l’appareil est de 45°C. Ne pas
l’utiliser au-delà de cette température.
• Débranchez toujours l’appareil si vous ne l’utilisez pas de manière prolongée ou
avant d’entreprendre des réparations.
• Les installations électriques ne peuvent être faites que par du personnel qualifié et
conformément aux régulations de sécurité électrique et mécanique en vigueur dans
votre pays.
• Assurez-vous que le voltage de la source d’alimentation de la zone dans laquelle
vous vous trouvez ne dépasse pas celui indiqué à l’arrière de l’appareil.
• Le cordon d’alimentation doit toujours être en condition parfaite. Mettez
immédiatement l’unité hors tension si le cordon est écrasé ou endommagé.
• Ne laissez jamais le cordon d’alimentation entrer en contact avec d’autres câbles !
• L’appareil doit être à la masse selon les règles de sécurités.
ATTENTION: afin de réduire le risque
d’électrocution, n’enlevez jamais le couvercle
de l’appareil. Il n’y a aucune pièce à l’intérieur
de l’appareil que vous pouvez remplacer vous-
FRANCAIS MODE D’EMPLOI
• Ne pas connecter l’unité à un variateur de lumière.
• Utilisez toujours les câbles appropriés et certifiés lorsque vous installez l’unité.
• Pour éviter tout choc électrique, ne pas ouvrir l’appareil. En dehors du fusible
principal, il n’y a pas de pièces pouvant être changées par l’utilisateur à l’intérieur.
•Ne jamais réparer ou court-circuiter un fusible. Remplacez systématiquement un
fusible endommagé par un fusible de même type et spécifications électriques !
• En cas de problèmes de fonctionnement sérieux, arrêtez toute utilisation de
l’appareil et contactez votre revendeur immédiatement.
• Utilisez l’emballage d’origine si l’appareil doit être transporté.
• Pour des raisons de sécurité, il est interdit d’apporter toute modification à l’unité non
spécifiquement autorisée par les parties responsables.
ENTRETIEN
Nettoyez l’appareil à l’aide d’un chiffon doux, légèrement humide. Evitez d’introduire
de l’eau à l’intérieur de l’appareil. N’utilisez pas de produits volatiles tels le benzène ou
le thinner qui peuvent endommager l’appareil.
FACE AVANT
1. DMX LED: clignote quand un signal DMX est détecté.
2. ECRAN LCD: affiche l’état de sortie des canaux et aide l’utilisateur pendant
l’installation des différents menus.
Durant une utilisation normale, l’écran affiche l’état de sortie des canaux (voir
image): l’écran montre 6 canaux. Au dessus de chaque canal il y a une barre qui
indique le niveau d’atténuation du canal. Le premier chiffre montre le nom du canal
qui a été modifié en dernier lieu. (dans cet exemple, le canal 6 est celui qui a été
modifié en dernier lieu)
JB SYSTEMS® 11/55 DSP6
JB SYSTEMS® 12/55 DSP6
FRANCAIS MODE D’EMPLOI
3. Touche MENU: est utilisée pour accéder aux différents menus. Consultez le
chapitre “MENUS” pour plus d’informations.
4. Touche UP: est utilisée pour faire défiler les menus ou pour accroître les valeurs.
5. Touche DOWN: est utilisée pour faire défiler les menus ou pour diminuer les
valeurs.
6. Touche ESC: est utilisée pour reculer d’un pas dans le menu ou pour quitter le
menu.
7. Touches des CANAUX: Le DSP6 peut fonctionner sans contrôleur pour les
signaux d’entrés. Ceci est une option très intéressante si vous avez besoin d’un
certain niveau de sortie pour chaque canal pendant une longue période (magasins,
stands d’exposition, pubs etc…) appuyez sur la touche du canal que vous voulez
régler et tenez-la enfoncée. Pendant que vous tenez cette touche enfoncée vous
pouvez utiliser les touches “up/down” pour changer le niveau de sortie du canal.
8. INDICATEURS des CANAUX: en plus de l’écran LCD, ces Leds vous montrent
l’état de sortie des canaux.
9. DISJONCTEURS: en cas de court-circuit, ces disjoncteurs se coupent afin de
protéger les paliers de sortie du DSP6. Après avoir inspecté votre installation vous
pouvez les rallumer. Dans des conditions normales, ces disjoncteurs sont toujours
allumés.
FRANCAIS MODE D’EMPLOI
CONNECTIONS
Cet appareil peut uniquement être installé par des techniciens
qualifiés, en suivant les règlements pour installations électriques qui
sont de rigueur dans votre pays! Remettez toujours les couvercles
métalliques en place après avoir terminé votre câblage et utilisez
toujours des presse étoupes (voir image) afin de protéger les câbles
de tractions et de frictions non désirées.
• INSTALLATION MONOPHASE (2 fils «L + N» + fil de masse (terre) «E»)
• Comme vous n’avez qu’un seul fil de phase (L) vous devez faire des ponts entre
• Connectez le neutre (N) à l’entrée N. (voir dessin)
• Connectez les charges aux canaux de sortie (2 connecteurs, appelés “L” et “N”)
• N’oubliez pas de relier correctement la masse!
FACE ARRIÈRE
les entrées L1/L2/L3 et connecter le fil de phase à ces entrées. (voir dessin)
Touts les connecteurs “N” sont reliés ensemble à l’intérieur du DSP6.
10. ENTREE DMX: connecteur XLR mâle qui est utilisé pour relier le DSP6 à un
contrôleur DMX ou à un autre appareil DMX de la chaîne.
SORTIE DMX: connecteur XLR femelle qui est utilisé pour relier le DSP6 à
l’appareil suivant de la chaîne DMX.
11. ENTREES ANALOGIQUES: le connecteur DIN à 8 broches est
utilisé pour les entrées analogiques 0~10Vdc. Référez-vous à
l’image à droite pour le câblage du connecteur.
Attention: l’entrée analogique ne fonctionnera que si l’option “DMX fail” est
réglé sur “Analog”et qu’aucun signal DMX est envoyé vers le DSP6 (le Led
DMX est éteint)
12. CANAUX de SORTIE: chacun des 6 canaux disposent de 2 câbles de sortie.
Pendant le branchement, faites attention de ne pas confondre les indications “L” et
“N” sur le panneau arrière.
13. MISE A LA TERRE: faites attention de bien effectuer la mise à la terre du DSP6!
14. BORNES DE CONNECTION DU NEUTRE: Ces 3 bornes sont relies ensemble à l’intérieur du DSP6.
15. BORNES DES PHASES D’ENTREE: Le DSP6 peut être connecté en monophasé
ou en triphasé. Référez-vous au chapitre suivant afin d’effectuer correctement les
connections.
JB SYSTEMS® 13/55 DSP6
• INSTALLATION TRIPHASEE (4 fils «L1 + L2 + L3 + N» + fil de masse «E»)
• Comme vous avez 3 fils de phase vous pouvez les relier directement aux entrées
L1/L2/L3. (voir dessin)
• Connectez le neutre (N) à l’entrée N. (voir dessin)
• Connectez les charges aux canaux de sortie (2 connecteurs, appelés “L” et “N”)
Touts les connecteurs “N” sont reliés ensemble à l’intérieur du DSP6.
• N’oubliez pas de relier correctement la masse!
JB SYSTEMS® 14/55 DSP6
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.