Interlogix True Vision TVP-5104, True Vision TVP-5105 Installation Manual

Page 1
TruVision
IP PTZ
Camera Installation
Guide
P/N 1073398-EN • REV A • ISS 15MAY18
Page 2
Copyright
© 2018 United Technologies Corporation,
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
Trademarks and
patents
Trade names used in this document may be
trademarks or registered trademarks of the manufacturers or vendors of the respective products.
Manufacturer
Interlogix
2955 Red Hill Avenue, Costa Mesa, CA
92626-5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The
Netherlands
Certification
FCC compliance
Class A:
This equipment has been tested and
found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own
expense.
Page 3
FCC conditions
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This Device must accept any interference
received, including interference that may cause
undesired operation.
ACMA compliance
Notice!
This is a Class A product. In a
domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Canada
This Class A digital apparatus complies with
CAN ICES-003 (A)/NMB-3 (A).
Cet appareil numérique de la classe A est conforme à la norme CAN ICES-003 (A)/NMB- 3 (A).
European Union
directives
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable
harmonized European standards listed under
the EMC Directive 2014/30/EU, the RoHS
Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products
marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more
information see: www.recyclethis.info.
Page 4
2013/56/EU & 2006/66/EC (battery directive):
This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which
may include lettering to indicate cadmium (Cd),
lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or
to a designated collection point. For more information see: www.recyclethis.info.
Product warnings and
disclaimers
THESE PRODUCTS ARE INTENDED FOR
SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and product safety information, please check www.firesecurityproducts.com/policy/product­warning/ or scan the following code:
Page 5
Contact information
and
manuals/tools/firmware
For contact information and to download the
latest manuals, tools, and firmware, go to the web site of your region.
Americas: www.interlogix.com
EMEA: www.firesecurityproducts.com
Manuals are available in several languages
Australia/New Zealand: www.utcfs.com.au
Page 6
Page 7
Installation Guide 1
Content
Product overview 2
Contact information and manuals/tools/firmware 2
Installation 3
Installation environment 3 Package contents 4 Camera description 7 IR illuminators 10 Alarm input and output connections 10
How to access the SD card slot 11 Restore default settings 12
Mounting the PTZ camera 13
Using the camera with an Interlogix NVR or Hybrid DVR or
another system 18
Using the camera with a TruVision Navigator 18
Accessing the camera over the internet 18
Specifications 19
TruVision IP PTZ camera 19 TruVision IR IP PTZ dome 20
Pin definitions 20
Page 8
2 Installation Guide
Product overview
This is the installation guide for TruVision IP PTZ Camera models:
TVP-5104
(2.0 MPX wall mount, 25X, H.264/H.265)
TVP-5105 (2.0 MPX wall mount, 36X, 200 m IR,
H.264/H.265)
Contact information and manuals/tools/firmware
For contact information and to download the latest manuals, tools, and firmware, go to the web site of your region.
Americas: www.interlogix.com
EMEA: www.firesecurityproducts.com
Manuals are available in several
languages.
Australia/New Zealand: www.utcfs.com.au
Page 9
Installation Guide 3
Installation
This section provides information on how to install the cameras.
Installation environment
When installing your product, consider these factors:
Electrical: Install electrical wiring carefully. It should be done by qualified service personnel. Always use a proper Hi-PoE (Max. 60 W) switch or a 24 VAC UL listed Class 2 or CE certified power supply to power the camera. Do not overload the power cord or adapter.
Ventilation: Ensure that the location planned for the installation of the camera is well ventilated.
Temperature: Do not operate the camera beyond the specified temperature, humidity or power source ratings. The operating temperature of the camera without heater is between -30 to +60°C (-22 to 140°F). Humidity is below
90%. For the outdoor cameras that feature built-in heaters, the operating temperature range is -40 to 60°C (-40 to140°F)
Moisture: Do not expose the camera to rain or moisture or try to operate it in wet areas. Turn the power off immediately if the camera is wet and ask a qualified
service person for servicing. Moisture can damage the camera and also create the danger of electric shock.
Servicing: Do not attempt to service this camera yourself. Any attempt to dismantle or remove the covers from this product will invalidate the warranty and may also result in serious injury. Refer all servicing to qualified
service personnel.
Page 10
4 Installation Guide
Cleaning: Do not touch the sensor modules with fingers. If cleaning is necessary, use a clean cloth with some ethanol and wipe the camera gently. If the camera will not be used for an extended period of time, put on the lens
cap to protect the sensors from dirt.
Package contents
Check the package and contents for visible damage. If any
components are damaged or missing, do not attempt to use
the unit; contact the supplier immediately. If the unit is returned, it must be shipped back in its original packaging.
PTZ camera
PTZ camera
Hex wrench
CD with Configuration
manual and TruVision Device Manager
Installation guide
Page 11
Installation Guide 5
Battery Disposal sheet
Equipment Disposal
sheet
IR PTZ camera
IR PTZ camera
Hinged back box
Page 12
6 Installation Guide
Hex wrench
CD with Configuration
manual and TruVision Device Manager
Installation guide
Equipment Disposal
sheet
Battery Disposal sheet
CAUTION: Use direct plug-in UL listed power supplies marked Class 2/CE certified or LPS (limited power source) of the required output rating as listed on the unit.
Page 13
Installation Guide 7
CAUTION: Risk of explosion if the battery is replaced by an incorrect type. Dispose of used batteries according to the
instructions.
Camera description
Figure 1: PTZ camera
Page 14
8 Installation Guide
1. Ethernet RJ45 connector
2. Audio in
(RED/WHITE)/out port (BLUE/WHITE)
3. 2 alarm outputs
(BROWN, ORANGE/WHITE)
4. 7 alarm inputs
(GREEN, BLUE, PURPLE, GRAY,
WHITE,
5. RS-485 port
a. Orange RS-485+
b. Yellow RS-485-
6. 960H analog output
7. 24 VAC power supply
8. Location to attach the safety lanyard
9. Reset button
Page 15
Installation Guide 9
BLACK/WHITE, BROWN/WHITE)
Note: Hi-PoE (Max. 60 W) or 24 VAC is required to power the PTZ.
Figure 2: IR PTZ camera
1. Ethernet RJ45 connector
2. 960H analog output
3. 7 alarm inputs
4. 2 alarm outputs
(WHITE_RED, WHITE_PURPLE)
5. Audio in (PURPLE)/out
port (PINK)
Page 16
10 Installation Guide
(YELLOW_BLUE,
YELLOW_ORANGE, YELLOW_GREEN, YELLOW_BROWN, YELLOW_PURPLE, YELLOW_GREY,
YELLOW_RED)
6. RS-485 port a. Orange RS-485+
b. Yellow RS-485-
7. 24 VAC power supply
Note: Hi-PoE (Max. 60 W) or 24 VAC is required to power the PTZ.
IR illuminators
The IR PTZ camera’s built-in IR illumination provides high­quality video in low-light environments, even when there is no other illumination available.
You can configure the IR illumination using the web browser or a recorder such as TVN and TVR. If the function is enabled, the IR light is ON when the camera enters night (black and white) mode. If disabled, the IR light is always OFF.
The visible IR range may vary due to multiple factors such as weather, IR reflection level of objects in the frame, lens adjustment, and camera settings. Please refer to the camera datasheet for the standard IR range.
Note: Avoid installing the IR camera in close proximity to a solid object, such as a tree or wall. The reflection will cause over-exposure and loss of detail in the field of view.
Alarm input and output connections
The alarm output can be used to turn on and off an external alarm device. Connect a 30 VDC/1 A external power supply to the alarm output. If using an AC power supply, an external
Page 17
Installation Guide 11
relay must be used to prevent electric shock and damage to the device. See Figure 3 below.
Figure 3: External alarm output
How to access the SD card slot
PTZ camera
Open the black plastic access panel on the back of the PTZ block. The SD card slot is in the corner, as shown below.
SD card
Black plastic access panel
Page 18
12 Installation Guide
IR PTZ camera
Open the black plastic access panel on the back of the PTZ block. The SD card location is shown in the figure below.
SD card slot
Reset button
Restore default settings
To reset the camera to default settings, press and hold the Reset button for 10 s and power on or reboot the camera. You can then restore the default settings, including the user name, password, IP address, port number., etc.
Page 19
Installation Guide 13
Mounting the PTZ camera
Mount the wall mount (not included) on the mounting surface)
You can mount the camera on indoor/outdoor solid walls. The following requirements are mandatory preconditions for wall
mounting:
The wall must be thick enough to install the expansion
screws.
Please ensure that the wall is strong enough to withstand
more than eight times the weight of the dome and bracket.
To mount the wall mount (not included) on the mounting
surface):
1. Attach the PTZ safety lanyard (depending on the type of PTZ, IR vs non-IR) to the wall mount. Refer to the wall mount installation guide for appropriate lanyard type, IR
vs non-IR PTZ.
2. Route the PTZ interconnect cables that are required for
the installation. Pull the cables through the wall mount
prior to completing the installation.
Page 20
14 Installation Guide
3. Use the wall mount as a template to mark out the mounting area. Provide an access hole in the mounting
surface for the interconnect cables. Drill four screw holes in the wall according to the mounting holes, and then
insert M8 expansion anchors (included with the wall mount) into the mounting holes.
4. Pull the interconnect cables through the wall mount prior
to installing the mount. The access area may ease the process when making the wiring connections.
5. Install the wall mount to the mounting surface by aligning the mounting holes with the expansion anchors.
6. Secure the wall mount with four nuts and washers.
Mount the PTZ camera on the wall mount
To mount the PTZ camera:
1. While leaving the protective plastic liner in place, use the provided wrench to loosen the four hex head screws that hold the bubble assembly in place.
2. Remove the bubble assembly. Remove and discard the tape and foam ring that are used to protect the PTZ during shipping.
Page 21
Installation Guide 15
Reinstall the bubble assembly, making sure that the rubber gasket remains in place. Fully tighten the four hex head screws to ensure a good seal.
3. Route the PTZ cable harness through the wall mount. A cable access panel is provide to ease the overall installation. Clip the wall mount safety lanyard to the PTZ, as shown.
4. Mount the PTZ to the wall mount using the three screws that are provided with the mount.
Page 22
16 Installation Guide
To mount the IR PTZ camera:
1. Pull the interconnect cables through the wall mount prior to installing the mount. Install the upper base to the wall mount.
2. Clip the IR IP PTZ on to the upper base.
3. Connect the IR IP PTZ safety lanyard to the IR PTZ, as
shown below. Refer to the wall mount installation guide for lanyard type.
Page 23
Installation Guide 17
4. Route the interconnect cables to the PTZ camera. Connect the corresponding network/power/RS-485 cables.
5. Raise the IR IP PTZ into position and tighten the three
hex bolts, using the supplied hex wrench, to secure the PTZ to the upper base.
Page 24
18 Installation Guide
Using the camera with an Interlogix NVR or Hybrid DVR or another system
Please refer to the NVR/DVR user manuals for instructions on connecting and operating the camera with these systems.
Using the camera with a TruVision Navigator
A camera must be connected to an Interlogix NVR or hybrid DVR to be operated by TruVision Navigator. Please refer to
the TruVision Navigator user manual for instructions on operating the camera with the TruVision Navigator.
Accessing the camera over the internet
Use the web browser to access and control the camera over
the internet.
Note: Any changes made to the cameras configuration only apply to this camera.
Change the administrator password once the set-up is complete. Only authorized users should be able to modify
camera settings.
To access the camera online:
1. In the web browser enter the camera’s IP address (default is 192.168.1.70). The Login dialog box appears.
2. Enter your user name and password.
Default user name: admin
A valid password range must be between 8 and 16 characters. You can use a combination of numbers, lower
Page 25
Installation Guide 19
and upper case letters, and special characters : _ - , . * & @ / $ ? Space. The password must contain characters
from at least two of these groups. We also recommend that you reset your password regularly. For high security systems, it is particularly recommended to reset the password monthly or weekly for better protection.
Click Login. The web browser screen appears in live mode.
3. Click the Configuration tab on the top of the screen and select the parameter to change.
Specifications
TruVision IP PTZ camera
Electrical
Voltage input
24 VAC
Power
consumption Hi-PoE (Max. 60W)
Miscellaneous
Connectors
24 VAC, Alarm In/Out, RS-485,
Ethernet RJ45 connector, Audio In/Out, 960H Output
Operating temperature
-40 to +65°C (-40 to +149°F)
Dimensions
260.2 × 250.2 × 327.0 mm (10.24 × 9.85 × 12.87 in.)
Weight
6 kg (13.23 Ib.)
Environmental rating
IP67, IK10
Page 26
20 Installation Guide
TruVision IR IP PTZ dome
Electrical
Voltage input
24 VAC
Power consumption
Hi-PoE (Max. 60W)
Miscellaneous
Connectors
24 VAC, Alarm In/Out, RS-485,
Ethernet RJ45 connector, Audio
In/Out, 960H Output
Operating temperature
-40 to +65°C (-40 to 149°F)
Dimensions
266.6 × 396.4 mm (10.50 × 15.61 in.)
Weight
8 kg (17.64 Ib.)
Environmental rating
IP66, IK10
Pin definitions
There are eight wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight and crossover cable connection:
Page 27
Installation Guide 21
Figure 1: Straight-through cable
1 White/Orange
White/Orange 1
2 Orange Orange 2
3 White-Green White-Green 3
4 Blue Blue 4
5 White/Blue White/Blue 5
6 Green Green 6
7 White/Brown White/Brown 7
8 Brown Brown 8
Figure 2: Cross-over cable
1 White/Orange
White/Orange 1
2 Orange Orange 2
3 White-Green White-Green 3
4 Blue Blue 4
5 White/Blue White/Blue 5
6 Green Green 6
7 White/Brown White/Brown 7
8 Brown Brown 8
Please make sure your connected cables have the same pin assignment and color as above before deploying the cables in your network.
Page 28
Loading...