Interlogix 60-806-95R-16Z Specsheet

Intrusion
Concord Express
Powerful, expandable security featuring encrypted Learn Mode technology
Overview
Concord® Express delivers integrated hardwire/wireless security, providing up to 24 zones of burglary and fire protection. For residential customers—both retrofit and new construction— Concord Express is a valuable and affordable security choice. Its modular design provides flexibility for creating system solutions that customers want. Concord Express is easy to install, simple to use, and complies with SIA False Alarm Standards.
The Concord Express panel comes standard with six hardwire zone inputs, of which one can be set up as a 2-wire smoke detector loop that can handle up to 10 detectors. A built-in radio receiver with 16 wireless zones allows for easy and inexpensive addition of any Learn Mode sensors, remote keychain touchpads and wireless panics, providing installation flexibility to meet the needs of users and installers. Encrypted Learn Mode technology secures every keychain touchpad transmission.
Two built-in outputs can be programmed to activate external devices during an alarm or other system events.
Adding a SnapCard outputs. The 8Z input SnapCard provides six regular hardwire zones and two 2- wire smoke loops. The 4Z/2 output SnapCard adds three regular hardwire inputs, one 2-wire smoke loop input, and two programmable relay outputs. The 4 output SnapCard adds four programmable relay outputs. Each card (one per panel) connects easily to the panel circuit board inside the cabinet for a clutter-free, professional installation. Expand the system further by adding a SuperBus 2000 8Z input module for eight additional zones per module.
expands system hardwire zone inputs and
Sta n dar d Fe atu reS
• 22 zones—six onboard hardwire inputs and 16 wireless zones
• 2- and 4-wire smoke detector compatibility
• 2 onboard programmable outputs
• Compatible with all Learn Mode sensors and Encrypted
Learn Mode keychain touchpads
• Panel auxiliary power provides 750mA (continuous)
• 16 user-programmable access codes
• Latchkey numeric paging
• SIA False Alarm Reduction standard
• 50-event history buffer
• Keyswitch arming using a hardwire or wireless zone
• Programmable from on-site alphanumeric touchpads or
offsite using Enterprise software
With 16 user-programmable access codes, residential customers can grant access privileges to several users. Numeric paging provides users with system status and latchkey notification.
Conduct quick and easy on-site programming with alphanumeric touchpads and a menu-driven text interface with shortcut menu numbers. For off-site programming, use Interlogix Enterprise downloader software.
interlogix.com
Concord Express
Powerful, expandable security featuring encrypted Learn Mode technology
North America
T 855-286-8889
Asia
T 852-2907-8108
Australia
T 61-3-9239-1200
Europe
T 32-2-725-11-20
Latin America
T 561-998-6114
Specifications
Power supply
Transformer Class II, 16.5VAC, 25VA, 60 Hz Backup battery 12VDC, 4Ah rechargeable, sealed, lead-acid
Battery backup time
Battery test
Transformer fuse Non-replaceable fuse Panel auxiliary voltage output
Communication formats
Dialing DTMF or pulse with integrated line seizure relay Formats supported SIA Digital II (300 bps) or Contact ID
Capabilities
Inputs
Input zones
Databus format SuperBus 2000 with auto-enrolling capability Databus capacity Up to 4 devices
Outputs
Output 1 (OUT1/+12V)
Output 2 (OUT2/OC) Open collector, 200mA max.
Auxiliary power output
Environmental
Operating temperature
Storage temperature -30 to 140°F (-34 to 60°C)
Relative humidity 90% max., noncondensing
Physical
Dimensions (HxWxD) 11.0 x 9.0 x 3.0 in. (280 x 229 x 76 mm) Weight 5.0 lbs. (2.27 kg) without batter y
Construction
Lock set Optional Color Gray Installation Wall mount
Regulatory
24 hours (when fully charged with appropriate external load)
15 minutes under load every 24 hours (every 4 hours for UL installations)
Current-limited 12VDC
2 central station phone numbers and 3 pager phone numbers
24 max., 22 built-in; 6 hardwire zone inputs and 16 wireless zones
12VDC, 1.25A (max. during alarm)
Regulated, current limited, self-resetting 12VDC, 750mA continuous
32 to 120°F (0 to 49°C) and up to 140°F (60°C)
under temporary conditions
0.038 in. (0.97 mm) 20-gauge steel, punched and formed
FCC Parts 15 and 68 UL 985, UL 1023, UL 1635 cUL
CSFM SIA CP-01 2000 False Alarm Prevention
Ordering Information
Concord Express panel
60-806-95R-16Z Concord
Expansion options
60-756 Combo Input/Output SnapCard 60-757 8Z Hardwire Input SnapCard 60-758 4-output SnapCard 60-770 SuperBus 2000 4-output Module 60-774 SuperBus 2000 8Z Input Module
Touchpad options
60-597-95 HiTech Handheld Touchpad 600-1064-95R Micro Key Fob, 4-button SAW
60-746-01/60-803-04
60-804-04
60-820 SuperBus 2000 Fixed Display LCD Touchpad 60-983 ATP-1000 Alphanumeric Touchpad
60-985/60-984
600-1020 FTP-1000 Fixed English Touchpad
Transformer options
60-822
60-822-CN
®
Express Control Panel
SuperBus 2000 2x16 and 2x20 LCD Alphanumeric Touchpads SuperBus 2000 2x20 Vacuum Fluorescent Display Alphanumeric Touchpad
ATP-2100 and ATP-2600 Alphanumeric Touchpads
16.5V, 25VA Standard Transformer, UL Listed for U.S. Applications
16.5V, 25VA Standard Transformer, cUL/CSA
Listed for Canadian Applications