Document Number: 466-1608 Re v. B November 2000

Product Summary

Each SuperBus 2000 4-Relay Output module adds four pro­grammable relay outputs to a compatible panel.
Examples of module uses include:
Turning on a CCTV camera during a burglary alarm. Turning on exit lights during a fire alarm. Activating backup cellular phones or long-range radios
if primary communications are inoperable.
Each module comes complete with mounting hardware. Power for the module is provided by the panel.
®
Advent programmed) output points.
UltraGard of 32 output points.
For additional security, the plastic case accommodates a magnetic reed switch to provide tamper protection . Simply connect a UL listed reed switch to the module built-in zone input or to one of the fire/security panel hardwire input zones.

SuperBus 2000 vs. SuperBus

panels can be expanded to a total of 124 (24 pre-
®
and Concord™ panels can be expanded to a total
8557109A.DS4
Installation Instructions

Module Components

Figure 1 shows the main module components and Table 1 describes them.
UNIT NUMBER DIP SWITCHES
BUS STATUS LED (RED)
POWER LED (GREEN)
OUTPUT RELAYS (4) SOFTWARE
VERSION LABEL SUPERBUS 2000
DEVICE ID NUMBER LABEL
WIRING TERMINALS
9710G01A.DSF

Figure 1. Module Circuit Board Components

SuperBus 2000 panels have the ability to auto-address mod­ule unit numbers. When the panel is initially powered up, the panel automatically reads the unique SuperBus 2000 device ID number and assigns a unit number to the module. This eliminates manually setting DIP switches and the chance of identical unit number conflicts.

SuperBus 2000 Panels

Advent Concord (software versions 2.0 and later)
SuperBus panels communicate with SuperBus 2000 mod­ules but require the mod ule unit number to first be set man­ually with DIP switches.

SuperBus Panels

UltraGard Concord (software versions 1.0–1.6)

SuperBus® 2000 4-Relay Output Module

Table 1: Module Component Descriptions

Component Function

Unit Number DIP Switches
BUS LED (Red) Flashes to indicate normal
POWER LED (Green)
Output Relays Form C (dry contact) output relays rated
SuperBus 2000 Device ID Number Label
Software Version Label
Wiring Terminals Used for power, bus, and output wiring
Used for manually setting module unit number (SuperBus panels).
communication with the panel. Indicates module power status.
4A @ 24VDC, 4A @ 24VAC, 1A @ 70VAC maximum.
Identifies the unique device ID (SuperBus 2000).
Identifies the installed software version.
connections. All terminals are Class 2 power limited.
1

Installation Guidelines

PRESS DOWN HERE AND PULL AWAY FROM BASE
8557G47B.DS4
Installation Guidelines
For the maximum number of bus devices and
touchpads per panel see Table 2.

Table 2: Maximum Bus Devices Per Panel

Panel Maximum Bus

Devices
Advent 62 UltraGard 8 Concord
(software versions 2.0 and later) Concord
(software versions 1.0–1.6)
(up to eight 4-Relay
Do not exceed the panel total DC output power rating
when using panel power for bus devices and hardwired detectors (see specific panel Installation Instructions).
Do not exceed the maximum wire length from the
panel to the module (see Table 3).

Table 3: Maximum Wire Lengths

Panel Maximum Wire Length

Advent UltraGard 22 ga. 500 ft./18 ga. 1000 ft.
22 ga. 200 ft./18 ga. 500 ft.
16
16
Output modules)

Installation

The relay output module can be mounted:
On a wall. Inside an Advent cabinet. Inside a Concord cabinet. Inside a SuperBus Module cabinet (60-698). Refer to
the cabinet Installation Instructions for installation procedures.
CAUTION
To prevent damaging the panel or card, disconnect the panel AC Power and backup battery(s) before installation.
CAUTION
You must be free of all static electricity when handling electronic components. Touch a bare metal surface before touching the circuit board.

Mounting the Module

Note
If connecting th e modu le to an UltraGar d panel it must be mounted on a wall. The module will not fit in the UltraGard cabinet.
Mounting the Module on a Wall
Concord
22 ga. 350 ft./18 ga. 900 ft.
When using self or remotely powered devices with an
Advent panel, do not exceed the maximum recom­mended wire length of 4000 feet using 22-gauge or larger wire.
Maximum module current draw with all output s ener-
gized is 180 mA. Each module draws 12 mA typical when outputs are not energized (idle).
Do not exceed the module output relay contact ratings
(
4A @ 24VDC, 4A @ 24VAC, 1A @ 70VAC maximum).

Tools and Supplies Needed

Screwdrivers Drill with bits Wire cutters/strippers 3/8-inch #6-32 self-tapping screws (included) 22-gauge or larger stranded wire (18-gauge or larger
for commercial applications)
1/4-inch press-fit reed switch and magnet (not
included) for cover tamper
1/4-inch #6-32 self tapping screws (not included) for
Advent cabinet mounting
Support standoff (included with Concord cabinet)
1. Remove the module cover and set it aside (Figure 2).
Figure 2. Removing the Cover
2. Place the back-plate on the wall and mark the mount­ing holes (Figure 3).
3. Drill holes and insert appropriate anchors.
4. Secure the back-plate to the wall with included screws.
2
SuperBus® 2000 4-Relay Output Module
Note
MOUNTING HOLES
9
SUPPORT STANDOFF
8573g64A.DSF
PANEL
END
MODULE
END
Installation
Mounting the Module in a Concord Cabinet
1. Remove AC panel power and disconnect the backup battery.
2. Remove and discard the module cover (Figure 2).
3. Insert a support standoff as shown in Figure 5 (sup­plied with panel) into the panel circuit board.
12345
6
MAGNET
CLIP
910111213
REED SWITCH
HOLDER
14 15
18
16
17
9710G02B.DSF
78
Figure 3. Mounting Holes
Mounting the Module in an Advent Cabinet
1. Remove panel AC power and disconnect the backup battery(s).
2. Remove the module cover and set it aside (Figure 2).
3. Turn the module upside down and line up the holes on the back-plate at the desired location (Figure 4).
4. Secure the back-plate to the cabine t using three ¼-inch #6-32 self-tapping screws (not included).
PANEL CABINET
(COVER NOT SHOWN)
Figure 5. Support Standoff
4. Slide the module back-plate onto the two clips located on the top-left corner or center of the cabinet (Figure 6).
The two mounting clips in the top-right corner of the cabinet are designated for a receiver module, but if a receiver module is not being used, the mounting clips may be used for the 4-Relay Output Module.
5. Push the lower-right corner of the module onto the support standoff (see detail in Figure 6).
6. Gently press the module up and onto the cabinet side tab.
USABLE MOUNTING
CLIPS (6)
CARD ON
MODULE
BACK-PLATES
SIDE TAB
MOUNTED MODULE
ROOM FOR 3RD
712G11A.DSF
MODULE
Figure 4. Mounting Module in Advent Cabinet
SuperBus® 2000 4-Relay Output Module
MOUNT WITH
SELF TAPPING
SCREWS
PANEL CABINET
(COVER NOT SHOWN)
9712G08A.DSF
DETAIL
SUPPORT STANDOFF
(Included with Concord
panel accessory package)
Figure 6. Mounting Module in Concord Cabinet
3
Loading...