Learn Mode Micro Door/Window Sensor Installation
Instructions
Product summary
The Learn Mode Micro Door/Window Sensor is
a supervised, wireless sensor that detects the
opening and closing of doors, w indows, or
drawers. The sensor and magnet are mounted
using double-sided adhesive tape (included).
When activated, the sensor transmits an open
(trip) or close (restore) signal to the panel.
Every 64 minutes, the sensor transmits a
supervisory signal to the panel, automatically.
The sensor is powered by a 3-VDC, lithium
coin-cell battery (CR2032). This battery is
replaceable by the installer or the user.
Installation guidelines
• Mounting the sensor on metal can reduce
its transmitting range. Therefore, test the
sensor from the desired location using the
dealer sensor test, before permanently
mounting it.
• Mount the sensor within 100 ft. of the
panel.
• Mount the sensor on the frame, and the
magnet on the door, w indow, or drawer. If
mounting on double doors, mount the
sensor on the least used door and the
magnet on the other door.
• Mount sensors at least 5 in. above the
floor to avoid damaging them.
Programming
The following steps describe the general
guidelines for programming (learning) the
sensor into panel memory. Refer to the
specific panel’s documentation for complete
programming details.
1. Set the panel to the program mode.
2. Proceed to the LEARN SENSORS menu.
3. Select the appropriate sensor group and
sensor number assignments.
4. When prompted by the panel to trip the
sensor for learning, remove the sensor
cover and slide the battery about half-way
out of the battery holder (see Figure 1
below). The system should acknowledge
learning the sensor by touchpad display
and/or audio (depending on the panel).
Figure 1: Tripping the sensor
5. Slide the battery back into the holder.
6. Exit program mode.
7. Place the cover back on the sensor.
Testing the sensor
1. Set the panel to the dealer sensor test
mode.
2. Take the sensor and magnet to the
desired mounting location, making sure to
line up their alignment marks w ith each
other.
3. Trip the sensor by pulling the magnet
away from the sensor.
P/N 466-1177 • REV E • Model No. 60-688-95 • October 2012 1 / 2
4. Listen for interior siren beeps to indicate
All Interlogix Learn Mode
Panels and Receivers
3-VDC, lithium coin-cell
battery (CR2032)
Operating
temperature range
10 to 120°F (-12 to 49°C)
Storage
temperature range
-30 to 140°F (-34 to 60°C)
1.75 x 0.80 x 0.50 in. (4.45 x
2.0 x 1.3 cm)
UTC Fire & Security Americas
Corporation, Inc.
1275 Red Fox Rd., Arden Hills,
MN 55112-6943, USA
This device complies with part 15
of the FCC Rules. Operation is
subject to the follow ing tw o
conditions: (1) This device may
not cause harmful interference,
and (2) this device must accept
any interference received,
including interference that may
cause undesired operation.
FCC ID: B4Z-664A-UDWS
US Patents 4,855,713, 4,864,636
and others pending.
how many rounds the panel receives from
the sensor. You should hear 6 to 8 beeps.
Note: The Learn Mode Micro Door/Window
Sensor has a built-in power-saver feature that
turns on automatically when the sensor is
tripped more than once, w ithin a 4-1/4 minute
time period.
When the power-saver feature is on, the
sensor transmits only half the usual number of
data rounds w hen tripped. For example, during
a dealer sensor test you normally expect to
hear up to 8 data rounds. When the powersaver feature is on, you may hear only up to 4
data rounds.
To be sure the sensor has acceptable
transmitting range to the panel, leave the
sensor undisturbed in the closed (non-alarm)
condition for 5 minutes before tripping it for
testing. This gives the sensor enough time to
turn off the power-saver feature so you can get
accurate sensor test results.
Mounting the sensor
After successful programming and testing are
completed, mount the sensor as follows:
1. Apply double-sided tape (included) to the
bottom of the sensor and mount the
sensor at the desired location.
2. Apply double-sided tape to the bottom of
the magnet and mount it at the desired
location, making sure the alignment mark
lines up w ith the sensor’s.
3. Retest the sensor using the procedure in
the section “Testing the Sensor.”
Regulatory information
Contact information
For contact information, see
www.utcfireandsecurity.com or
www.interlogix.com.
For technical support, Toll-free: 888.437.3287
in the US including Alaska, Haw aii, Puerto
Rico, and Canada. Outside the tool-free area:
Contact your dealer.
Specifications
2 / 2 Learn Mode Micro Door/Window Sensor Installation Instructions
Trademark/Copyright
© 2012 UTC Fire & Security Americas
Corporation, Inc.
Interlogix is part of UTC Climate Controls &
Security, a unit of United Technologies
Corporation.
All rights reserved.