Product summary
This lightweight, portable touchpad allows you to control Concord
, Concord Express™, and
Advent
®
panels. You can arm and disarm your security system, bypass sensors, control lights, activate emergency alarms, and check system status. Features include:
Automated low-battery reports to the panel.
Police, Fire, and Auxiliary panic buttons.
Automated supervisory reports to the control
panel every 64 minutes.
Long life (5 to 8 year) 3 V DC lithium battery.
• Wall-mount option.
Installation
Observe the following guidelines:
Avoid mounting the touchpad near excessive
metal or electrical wiring, including furnace and utility rooms.
Avoid mounting in areas with excessive
moisture.
Avoid mounting the touchpad where
temperatures exceed operating limits of 10° to 120°F (-12° to 49°C).
Refer to appropriate control panel
documentation for information about RF ranges for the wireless touchpad.
To install the battery:
1. Remove cover and install battery (see
Figure 1 below).
Figure 1:
Install battery
8341G02A.DS4
2. To replace the battery cover, align the two exposed tabs with the touchpad’s front and back cover seam (see Figure 2 below).
3.
Press down on the battery cover and slide into place.
Figure 2: Replacing the battery cover
EXPOSED
TAB
TOUCHPAD
SEAM
EXPOSED
TAB
Programming
Note: For SX-V Special systems, if the touchpad
is mounted on a wall or remains at the installation site, set upper sensor number 89 to ON. If the touchpad is to be removed from the site (i.e. placed in an automobile), set upper sensor number 89 to OFF.
The following steps provide a general guideline for programming (learning) the wireless touchpad into panel memory. Refer to specific panel documentation for complete programming details.
1. Set your control panel to PROGRAM mode.
2. Proceed to LEARN TOUCHPAD menu.
3. Enter the ADD/PROGRAM menu to program your wireless touchpad into panel memory.
4. Press BYPASS on the touchpad when prompted for touchpad activation.
5. At the panel, exit the PROGRAM mode.
Testing
Remind your customer to test their security system and wireless touchpad weekly. Refer to the control panel documentation for complete instructions on testing and operating the security system.
P/N 466-1012 • REV E • Model No. 60-597 • January 2011 1 / 2
Note: A g
reen light flashes each time a number or function button is pressed. A red and green light flash each time a panic button is pressed.
1. Notify the central monitoring station that (1)
you are testing the security system and (2) not to dispatch emergency services.
Technical support, www.interlogix.com/customer-support
www.utcfireandsecurity.com or www.interlogix.com
Copyright © 2011 UTC Fire & Security Company. All rights reserved
2. Arm and disarm the system with the
touchpad from various locations in order to determine usable range.
3. Press STATUS to check the current arming
level.
4. Select Direct and Indirect to bypass sensors.
5. Press and hold each panic button until the
red/green indicator light stops flashing and the appropriate alarm sounds.
6. Turn lights on or off (see system
documentation).
7. Press and hold the buttons marked
1 and 2
at the same time to mute the touchpad. Continue to hold the buttons until you hear a series of confirmation beeps.
8. Press various buttons to test the mute
feature.
9. Press and hold the buttons marked
1 and 2
at the same time to turn off the mute function. Continue to hold the buttons until you hear a series of confirmation beeps.
10. Contact the central monitoring station after
you have finished testing the touchpad.
Mounting the touchpad
Test the wireless touchpad at a desired location. Ensure that a clear RF signal exists between the touchpad and control panel. After successfully testing for a clear RF signal, you can mount the touchpad as follows:
1. Secure the touchpad mounting bracket to a
desired surface. Use the screws from the accessory pack to mount the bracket (see Figure 3 below).
Figure
3: Securing the mounting bracket
Screws
Mounting
Holes
2. Attach the touchpad to the mounting bracket
by placing the touchpad bottom into the
bracket bottom. Press the touchpad into place to ensure a secure fit (see Figure 4 below).
Figure
4: Attach to mounting bracket
Specifications
Model no. 60-597 RF frequency 319.5 Compatibility Concord, Concord
Express, and Advent security panels
Power requirements One 3.0 V DC lithium
battery Battery life 5 to 8 years Storage temperature -40° to 140°F (-34° to
60°C) Operating Temperature
10° to 120°F (-12° to
49°C) Maximum Humidity 90% relative humidity,
non-condensing Dimensions 2.1 x 0.86 x 6.1 in. (5.33 x
2.18 x 15.5 cm)
Regulatory information
Manufacturer UTC Fire & Security Americas
Corporation, Inc. 1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
FCC compliance: This device complies with FCC Rules Part 15. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Interlogix can void the user’s authority to operate the equipment. FCC ID No.: B4Z-861-HTTP