Configuration Guide System / Spares / Accessories List
March 2008
Rev 1.2
Reference guide to assist customers and the field in ordering the servers,
accessories and spares
Carrier Grade Server TIGH2U
~Subject to Change Without Notice~
March 2008
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS.
NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL
PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS
AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY
WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO
SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO
FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY
PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not
intended for use in medical, life saving, life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without
notice.
Intel server boards, server chassis, and processors may contain design defects or errors
known as errata, which may cause the product to deviate from published specifications.
Current characterized errata are available on request.
Intel, Intel Xeon, Pentium, and the Intel logo are trademarks or registered trademarks of
Intel Corporation or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others.
Updated for launch with new web links and format
changes
Updated to reflect added support for Xeon L5410
1.2 March 2008
processor; updates to accessories/spares section;
misc. format/structure changes.
Document Table of Contents
I. INTRODUCTION........................................................................................................ 4
II. PRODUCTION SKUS..................................................................................................5
III. PRODUCTION SPARES/ACCESSORIES LIST......................................................... 10
APPENDIX A. RACK MOUNTING OPTIONS FOR 1U AND 2U INTEL® COMMUNICATIONS
RACK MOUNT SERVERS................................................................................................. 13
3/28/2008 v 1.2 3 of 20
I. Introduction
Product Description:
The Intel® Carrier Grade Server TIGH2U is the 4th generation of the 2U x 20”D Intel®
Telecom and Industrial Grade Rack Server. The TIGH2U supports the 45nm Quad-Core
Intel® Xeon® processor 5400 Series with 12M L2 cache, coupling high performance with
power efficiency to provide improved performance-per-watt over previous-generation
rack-mount servers.
The TIGH2U is a NEBS-3 and ETSI certified product which is suited for a host of
applications in the telecom Central Office and industrial environment. The server is
targeted to OSS (Operations System and Support), Billing, Provisioning, Softswitch,
Media Server, Wireless and Unified Messaging, Call Center and many other
applications. It can also support manufacturing, industrial, utility and even military
applications where a rugged, highly reliable server is required for harsh environments
such as dust, high altitude, fire hazard, earthquake propensity, and high ambient
temperatures.
More product information is available at the following websites:
This document provides details on what parts are available for ordering of the Intel®
Carrier Grade Server TIGH2U production systems. This includes PID and MM#
information for System SKUs, Accessories & Spares, as well as other Intel parts that
are supported by the TIGH2U product.
Supported third-party components are not covered by this document, and may be
found in the Tested Hardware and Operating System List (THOL) for this product.
3/28/2008 v 1.2 4 of 20
II. Production SKUs
The
TIGH2U Production SKUs that can be ordered are listed below:
PID Order Code Description MM#
TLHA0201W
TLHD0201W
Intel® Carrier Grade Server TIGH2U
Base Model 0 with AC Power Supply.
Intel® Carrier Grade Server TIGH2U
Base Model 0 with DC Power Supply.
890868 1
890910 1
Min. Order
Qty.
See the TIGH2U Base Model 0 Configuration table further down in this section for a
list of components included in each base model 0 SKU.
Production SKUs are offered as either an AC or a DC version. The Product
Identification code or PID of all SKUs contains the letter “A” for AC or “D” for DC as
the 4th digit of the PID.
Both Production SKUs are base model 0 SKUs, (no processor, heatsink, memory, hard
drive, power cord, operating system, or plug-in adapters are provided). Those
components must be ordered separately as Accessories from Intel or from third party
vendors listed in the Tested Hardware and Operating System List (THOL).
Power Cords are not included with the Mod 0 system. For AC Power cords, order the
NA – North American power cord below. This power cable is RoHS-compliant.
PID MM# Comments
PWRCABLEUS 816324
This AC power cable can be ordered by North
America (NA) customers. International customers
should procure their specific power cords directly.
Note: Ensure that customers have the appropriate technical support and contact
before placing the first order.
3/28/2008 v 1.2 5 of 20
TIGH2U Base Model 0 Configuration
All Production SKUs are base model 0 SKUs (no CPU, heatsink, memory, hard drive or
plug-in adapters are provided). Those components must be ordered separately as
Accessories from Intel or from third party vendors listed in the Tested Hardware and
Operating System List (THOL). The below table lists how many of each component is
included in the Production model 0 SKU.
The table below lists which components are included in the base model 0 SKUs and
which ones must be ordered separately or as optional accessories.
Component Description
AC Mod 0
Configuration
AC power supply (600 W) 1 included DC power supply (600 W) - 1 included
Filler Panel in 2nd power supply bay 1 included
Chassis (bezel, sheet metal, top cover, PCI carrier) 1 included
Server Board T5000PAL 1 included
Bezel (unpainted) 1 included
PCI Riser FH-FL (two PCI-Express and one PCI-X slots) 1 included
PCI Riser LP (two PCI-Express slots) 1 included
FB-DIMM slots (memory not included) 8 included
Trays for hot-swap 2.5” SAS Hard Disk Drives 6 included
Filler Panel in optical device bay 1 included
Rear Panel GbE NIC (Cu) ports (via Server Board) 2 included
Server Deployment Toolkit (CD) 1 included
Quick Start Guide 1 included
Power Cable Purchase separately1
SW RAID 0/1/10 Included
HW RAID 5 Optional Accessories2
Intel® Z-U130 Value Solid State Drive Optional Accessory2
Mounting kit for Intel® Z-U130 Value Solid State Drive Optional Accessory2
Remote Management Module 2 Optional Accessory2
PCI-X FH-FL Riser (3 PCI-X slots) Optional Accessories2
Ethernet I/O Module (dual Gigabit rear ports) Optional Accessory2
SAS I/O Expansion Module (x4 external rear port) Optional Accessory2
Rack Mount Kits Optional Accessory3
Processor (refer to “Details on Ordering Processors”) Purchase separately4
Heatsink Accessory or purchase separately
Memory Purchase separately4
Hard Disk Drive Purchase separately4
Optical Drive Purchase separately4
1
Refer to AC power cord accessory in this section
2
Refer to “Production Spares/Accessory List” in section III
3
Refer to “Rack Mounting Options” in the Appendix
4
Should be purchased separately (parts not listed in this document)
DC Mod 0
Configuration
3/28/2008 v 1.2 6 of 20
Notes on the TIGH2U Model 0 Configuration and Options:
PCI Risers
o The base configuration comes standard with two PCI Risers supporting up to
five PCI slots. These include:
One low-profile riser supporting two PCI-Express (PCIe) slots
One full-height, full-length riser supporting three slots: two PCIe x4
and one PCI-X.
o Additional full-height, full-length risers (below) are supported and available
as accessories (refer to “Production Spares/Accessories List” in section III).
PCI-X (active): three independent PCI-X, each with maximum 133
MHz
PCI-X (passive): two PCI-X with maximum 100 MHz and one PCI-X (66
MHz) all on a shared PCI bus
HW RAID
o While SW RAID 0/1/10 is supported on the base configuration, HW RAID 5
support can be enabled via a set of optional accessories (refer to “Production Spares/Accessories List” in section III).
o Components required are NSCRAID01W (NSC2U RAID5 Kit – includes the I-
Button (license), battery cable) and the AXXMINIDIMM (128 MB Mini DIMM
registered DDR-2 for RAID cache.)
o An additional option is the AXXRSBBU3 (Intel® RAID Smart Battery Backup
module provides up to 72 hours of cache memory retention when used with
AXXMINIDIMM). The cable to connect the battery is included in the
NSCRAID01W kit.
Intel® Z-U130 Value Solid State Drive
o Support for the Intel® Z-U130 Value Solid State Drive is available via a
selection of optional accessories (refer to “Production Spares/Accessories List” in section III).
o Components required are an Intel® Z-U130 Value Solid State (select desired
capacity) as well as a mounting kit (TMWVSSDRIVE01W) to mount it inside
the chassis.
o Solid state drives are available in several sizes, enabling an array of product
customization options. These drives securely mount inside the chassis
offering
Storage: independent of traditional disk drives
Boot OS from solid state drive; store data on hard drive
Store backup image of boot drive
Add a server partition to the server
Any other customer design options
3/28/2008 v 1.2 7 of 20
IO Option Modules
o These modules, available as optional accessories, attach to the system
board via a proprietary connector, and provide additional IO through the
rear bulkhead.
The AXXGBIOMO option module provides two Gigabit Ethernet NICs.
The AXXSASIOMOD option module provides one x4 external SAS port.
o Note: Using the AXXGBIOMOD on the TIGH2U may result in non-compliance
of NEBS GR-63 short term operating conditions.
o For ordering details, refer to “Production Spares/Accessories List” in
section III.
Air Filters are not provided with the TIGH2U base system. If air filters are
required by customer, then customer must purchase them separately.
For more detailed information on the TIGH2U, refer to the web links below.
Additional Product Details
Check the following web site for more information on the TIGH2U:
Product information including specifications, compatibility, user’s guides, drivers,
firmware, and software associated with the Intel® Carrier Grade Server TIGH2U is
available from Intel Customer Support.
Intel® Carrier Grade Server TIGH2U Support Web Site
If you can not access the documents using the links provided, please contact your
FAE/FSE for assistance.
3/28/2008 v 1.2 8 of 20
Details on Ordering of Processors:
The TIGH2U supports the Quad-Core Intel® Xeon® processor 5400 Series. Ordering
details for the CPUs for use in TIGH2U are listed below, and includes both Tray (for
OEMs) and Boxed (Retail channel) processors.
Quad-Core Intel® Xeon® Processors Supported by TIGH2U:
The above processors are tested and supported by Intel and are recommended for
long availability and support.
Heatsinks
o This product requires Passive heatsinks. The boxed processors listed above include
a Passive Heatsink Kit, made of aluminum. Do not use Active Fan Heatsinks, which
are provided in some Retail Boxed Processors.
o For Tray processors, you will need to procure a Heatsink for each processor (see
NSCSNKCLP01 in the Spares/Accessories list below). This is a copper heatsink.
There are no clips needed for this heatsink, since the heatsink includes captive
screws.
Boxed Processor Tray Processor Processor
Product Code MM# Product Code MM#
o If ordering other Boxed Processors (not listed here), do not use the fansink, which
might be included.
Note that CPU product codes can change, and that the above is a snapshot current as
of 3/28/2008. Please consult with your Intel representative for SSpec or MM# which
may be needed for ordering the CPU. Any differences in functionality is reported in
Monthly Specification updates available on http://developer.intel.com
.
3/28/2008 v 1.2 9 of 20
III. Production Spares/Accessories List
Below are the Spares parts and Accessories that may be ordered with the TIGH2U
system. Any of these parts may be ordered as spares for part replacement purposes
or as additional customer inventory. Some of the parts below are not included in the
TIGH2U system base model and may be ordered as accessories for purposes of
upgrading the base model to include additional features.
Note, for a listing of additional compatible accessories, such as Optical Devices for
use with the CD-ROM carrier, please refer to the Tested Hardware and Operating
System List (THOL).
PID Order Code Description Contents
TLIACPSU003
TLIDCPSU003
NSCSNKCLP01
HW RAID
NSCRAID01W
AXXRSBBU3
AXXMINIDIMM
Remote Management
AXXRMM2
AXXRMM2BULK
TIGI2U AC Power Supply
TIGI2U DC Power Supply
NSC2U CPU Heatsink
NSC2U RAID5 Kit
Intel® RAID Smart Battery Backup
module: for use with Intel® Integrated
Server RAID (requires NSCRAID01W
plus mini DIMM), provides up to 72
hours of cache memory retention
when used with AXXMINIDIMM.
128 MB Mini DIMM registered DDR-2
for RAID cache.
Note: enabling RAID capability also
requires Intel RAID Activation Key–
NSCRAID01W
Intel® Remote Management Module
2 (RMM2) - Single Pack
Power distribution
board, with integrated
wire harness
Included in
Base Model
(Y/N)
Y
Y
Y
MM#
891494
893601
889805
Min.
Order
Qty
1
1
1
NSCSASBSBDW
NSCSASBKPLNW
NSCBRIDGEBDW
NSCDVDENGTABW
FXX25HDDCAR
NSC2U T5000PAL Server board
NSC2U SAS Backplane
NSC2U Bridge board
NSC2U DVD Drive Engagement Tab
TIGW1U SAS HDD carrier
Board
Backplane
Board, insulator
Blue plastic
engagement bracket
& black plastic locking
clip, screws
Carrier, black plastic
filler, screws (4)
Y
Y
Y
Y
Y
889828
889829
889852
889845
881681
1
1
1
1
10
(order in
multiples
of 10)
3/28/2008 v 1.2 12 of 20
Appendix A. Rack Mounting Options for 1U and 2U
Intel® Communications Rack Mount Servers
Rack mounting kits for 2-post or 4-post, 19-inch or 23-inch racks are offered for this
product. Please refer to the tables below for the correct options to suit your needs.
All rack mount kits listed are suitable for 1U and 2U Intel® Communications Rack
Mount Servers. Installation instructions are included in each kit.
2-post Rack Mounting Kit Options
Rack width Post depth Rack fastener hole spacing
Applicable kits:
19 inch 23 inch 3 inch 5 inch EIA-Wide EIA-Universal ETSI
The TMLPSLIDE01 kit contains server securing brackets. The rails and other options
Front-post to
rear-post distance
Min
(inches)
20 24
20 24
20 24
22.5 28 or 34††
Max
(inches)
for mounting the server are available through other venders such as Accuride
(http://www.accuride.com/index2.php).
††
34-inch span requires the optional Accuride "Long Bracket" kit.
Rack fastener
hole spacing
EIA-
Wide
EIA-
Universal
ETSI
3/28/2008 v 1.2 13 of 20
TMLCMOUNT21
The TMLCMOUNT21 kit mounts Intel® Communication Rack Mount Servers to a 2-post,
central office type, 19” wide rack. This kit consists of simple L-shaped brackets;
which fasten to the sides of the server and to the rack.
TMLCMOUNT21
3/28/2008 v 1.2 14 of 20
TMLPMOUNT41, TMLPMOUNT51 and TMLPMOUNT52
TMLPMOUNT41/51/52 series mounts Intel® Communication Rack Mount Servers to 2post or 4-post racks.
TMLPMOUNT41 and TMLPMOUNT51 are used for mounting servers on 19” wide racks.
These racks are considered standard EIA (universal hole spacing) racks.
TMLPMOUNT52 is used for mounting servers on 23” wide racks. These racks could be
standard EIA (universal or wide hole spacing) or ETSI (European) racks.
TMLPMOUNT41/51/52 series are designed with a slide-in rail-type system. Although
the mounts are designed as rails, they are not sliding rails. This means the servers can
be slid into the racks for installation purpose, but the rails are not designed to
support a mounted server during service.
TMLPMOUNT4x/5x feature comparison
Slide pull-out
locking feature
TMLPMOUNT41 No1
TMLPMOUNT51 Yes
TMLPMOUNT52 Yes
Slide interface
Plastic
strips
Xylan
coating
Xylan
coating
material
2
EIA-Wide or EIA-
3
3
EIA-Wide, EIA-
Universal or ETSI
spacing
4-post rack hole
EIA-Universal
Universal4
2U-tall nut bar
Not
included
Included
Included
5
5
access6
Front
access
Front
access
2-post chassis
securing screw
Side
location
Notes:
1. Extra care must be exercised with TMLPMOUNT41 to securely hold the server
with one's hands when sliding it out of the rack, else the server may fall to the
ground as its being removed.
2. Plastic strips on TMLPMOUNT41 have peeled off in some customer installations.
Consequence: The parts are usable, but the server may have somewhat of a
"scrape-in feel" rather than "slide in". Also, the rails will fit sloppier, so the
side-located chassis securing screws may be difficult to align in 2-post
installations. Replacement material is available from the plastic strip
manufacturer.
3. Xylan is a tough, low-friction coating similar to Teflon.
rack
"HP Mulan
interference"
Interference
No
Interferance
N/A
3/28/2008 v 1.2 15 of 20
4. EIA-Wide spacing does n't have the interstitial hole that is present in EIAUniversal. TMLPMOUNT51 contains an adapter bracket to overcome this EIAWide issue.
5. This component (2U Nut Bar) enables installation of a rail kit into a 1U rack slot
when there is already equipment installed both above and below that open
slot.
6. The sides of the server must be accessible when using TMLPMOUNT41 in 2-post
racks.
3/28/2008 v 1.2 16 of 20
The diagrams above summarize the components and “slide-in rail-type” system of the
TMLPMOUNT41. It can be adapted for a 2-post or 4-post installation.
3/28/2008 v 1.2 17 of 20
The main difference between the TMLPMOUNT41 and TMLPMOUNT51/52 series is that
the TMLPMOUNT41 series uses a screw to lock the server in place via the Universal
Mounting Bracket, whilst the TMLPMOUNT51/52 series has an additional Slide Pull-Out
Locking feature.
The Universal Front Mounting Bracket on the TMLPMOUNT41
The Slide Pull-Out Locking feature on the TMLPMOUNT51/52
3/28/2008 v 1.2 18 of 20
TMLPSLIDE01
The TMLPSLIDE01 is an accessory kit designed for use in conjunction with slide rails to
produce a rack mounted serviceable server. The TMLPSLIDE01 kit contains two
Universal Front Mounting Brackets
that secure the server to the front of the rack. The
sliding rails and optional mounting brackets required to mount the server must be
purchased through the channel. For example, the Accuride 22-inch Model 305A-LR
slide rails are designed to mount a server for “in-rack service.” This example would
also use an Accuride mounting bracket kit and the TMLPSLIDE01.
Universal Front Mounting Bracket with securing tab
Note: Using slide rails may result in non-compliance with Seismic Zone 4
requirements of NEBS-3 certification.
Customers should order RoHS items for shipments going to the European Union (EU).
3/28/2008 v 1.2 19 of 20
Although these mounts have been designed for industry standard racks, please consult
with your Intel Field Application or Sales Engineer before selecting racks for these
servers.
rd
Compatible rack mounting kits may also be obtained from 3
party suppliers.
3/28/2008 v 1.2 20 of 20