Intel S3000AH - Entry Server Board Motherboard, S3000AHLX - Entry Server Board Motherboard, S3000AHV - Entry Server Board Motherboard User Manual

Intel® Server Board S3000AH User’s Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products
Intel Order Number D56209-003
Disclaimer
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
* Other names and brands may be claimed as the property of others.
Copyright © 2006, Intel Corporation. All Rights Reserved
ii Intel® Server Board S3000AH User’s Guide
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the
®
Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/
Intel
motherboards/server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment T oolkit 2.0 CD
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-
010770.htm.
®
Server Deployment Toolkit 2.0 CD ou bien
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel
support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment Toolkit 2.0 CD y/o en http://
重要安全指导
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm
上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。
iv Intel® Server Board S3000AH User’s Guide
Warnings
Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server Board S3000AH User’s Guide v
vi Intel® Server Board S3000AH User’s Guide
Preface
About this Manual
Thank you for purchasing and using the Intel® Server Board S3000AH. This manual is written for system technicians who are responsible for troubleshooting,
upgrading, and repairing this server board. This document provides a brief overview of the features of the board/chassis, a list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Title of document. For the latest version of this manual, see http://support.intel.com/ support/motherboards/server/S3000AH/.
Manual Organization
Chapter 1 provides a brief overview of the Intel® Server Board S3000AH. In this chapter, you will find a list of the server board features, photos of the product, and product diagrams to help you identify components and their locations.
Chapter 2 provides instructions on using the utilities that are shipped with the board or that may be required to update the system. This includes how to navigate through the BIOS Setup screens, how to perform a BIOS update, and how to reset the password or CMOS. Information about the specific BIOS settings and screens is available in the Intel 3000 Series Chipsets Server Board Family Datasheet. See "Additional Information and
Software" for a link to the Intel
Chapter 3 provides instructions on adding and replacing components. Use this chapte r for step-by-step instructions and diagrams for installing or replacing components such as the memory , processor, control panel board, and the battery, among other components.
Chapter 4 provides troubleshooting information. In this chapter, you will find BIOS error messages and POST code messages. You will also find suggestions for performing troubleshooting activities to identify the source of a problem.
®
3000 Series Chipsets Server Board Family Datasheet.
®
Product Accessories
This server board is compatible with the following Intel® Server Chassis:
Intel
®
Entry Server Chassis SC5295UP
You may need or want to purchase one or more of the following accessory items for your server:
Processor, memory DIMMs, hard drive, CD-ROM or DVD-ROM drive, RAID controller , operating system.
For information about which accessories, memory, processors, and third-party hardware have been tested and can be used with your board, and for ordering information for Intel products, see http://support.intel.com/support/motherboards/server/S3000AH/ compat.htm.
Additional Information and Software
If you need more information about this product or information about the accessories that can be used with this server board, use the following resources. These files are available at http://support.intel.com/support/motherboards/server/S3000AH/
Unless otherwise indicated in the table below, once on this Web page, type the document or software name in the search field at the left side of the screen and select the option to search "This Product."
Table 1. Additional Information and Software
For this information or
software
For in-depth technical information about this product
For BIOS settings and chipset information
If you just received this product and need to install it
For virtual system tours and interactive repair information
Accessories or other Intel server products
®
Server Board S3000AH Technical Product Specification
Intel
®
Intel
Server Board S3000AH Technical Product Specification
®
Intel
Server Board S3000AH Quick Start User's Guide in the
product box
A link to the SMaRT Tool is available under "Other Resources" at the right side of the screen at
http://support.intel.com/support/motherboards/server/S3000AH
Spares and Configuration Guide
Use this Document or Software
viii Intel® Server Board S3000AH User’s Guide
Table 1. Additional Information and Software
For this information or
software
Hardware (peripheral
Tested HardwareOperating Systems List
Use this Document or Software
boards, adapter cards) and operating systems that have been tested with this product
Chassis that have been
Reference Chassis List
tested with this product
Processors that have
Supported Processors been tested with this product
DIMMs that have been
Tested Memory List tested with this product
To make sure your system
Power Budget Tool falls within the allowed power budget
For software to manage your Intel
®
server
®
Intel
System Management Software
For drivers Driver (for an extensive list of available drivers)
Operating System Driver (for operating system drivers)
For firmware and BIOS
Firmware Updates updates, or for BIOS recovery
For diagnostics test
Diagnostics software
See also the Intel® Server Deployment Toolkit 2.0 CD that came with your server board.
Intel® Server Board S3000AH User’s Guide ix
x Intel® Server Board S3000AH User’s Guide
Contents
Safety Information ..................................................................................................... iii
Important Safety Instructions ................................................................................................ iii
Wichtige Sicherheitshinweise ............................................................................................... iii
Consignes de sécurité .......................................................................................................... iii
Instrucciones de seguridad importantes ............................................................................... iii
Warnings ................................................................................................................................ v
Preface .......................................................................................................................vii
About this Manual ................................................................................................................ vii
Manual Organization ............................................................................................................vii
Product Accessories ............................................................................................................viii
Additional Information and Software ....................................................................................viii
Chapter 1: Server Board Features ............................................................................ 1
RAID Support ......................................................................................................................... 4
SATA Server Board .......................................................................................................4
®
Intel
Embedded Server RAID Technology .................................................................. 5
®
Intel
Matrix Storage Manager ......................................................................................5
Connector and Component Locations ...................................................................................6
Configuration Jumpers .........................................................................................................12
Back Panel Connectors .......................................................................................................13
Hardware Requirements ......................................................................................................14
Processor .................................................................................................................... 14
Memory ........................................................................................................................14
Power Supply ..............................................................................................................14
Optional Hardware ............................................................................................................... 15
Hard Disk Drives ..........................................................................................................15
Chapter 2: Server Utilities ........................................................................................17
Using the BIOS Setup Utility ................................................................................................17
Starting Setup ..............................................................................................................17
If You Cannot Access Setup ........................................................................................17
Setup Menus ...............................................................................................................17
Upgrading the BIOS .............................................................................................................19
Preparing for the Upgrade ...........................................................................................19
Upgrading the BIOS ....................................................................................................20
Chapter 3: Hardware Installations and Upgrades .................................................23
Before You Begin ................................................................................................................. 23
Tools and Supplies Needed ........................................................................................23
Installing and Removing Memory ........................................................................................23
Intel® Server Board S3000AH User’s Guide xi
Installing DIMMs .......................................................................................................... 23
Removing DIMMs ........................................................................................................ 25
Installing the Processor ............................................................................................... 26
Installing the Heat Sink(s) ........................................................................................... 28
Removing a Processor ................................................................................................ 29
Replacing the Backup Battery ............................................................................................. 30
Appendix A: Getting Help ........................................................................................33
World Wide Web .................................................................................................................33
Telephone ........................................................................................................................... 33
Appendix B: Regulatory and Compliance Information .........................................37
Product Regulatory Compliance .......................................................................................... 37
Product Safety Compliance ......................................................................................... 37
Certifications / Registrations / Declarations ................................................................ 38
Product Regulatory Compliance Markings .................................................................. 38
Electromagnetic Compatibility Notices ................................................................................ 39
FCC (USA) .................................................................................................................. 39
Industry Canada (ICES-003) ....................................................................................... 40
Europe (CE Declaration of Conformity) ....................................................................... 40
Taiwan Declaration of Conformity (BSMI) ................................................................... 40
Korean Compliance (RRL) .......................................................................................... 41
CNCA (CCC-China) .................................................................................................... 41
Restriction of Hazardous Substances (RoHS) Compliance ................................................ 42
End-of-Life / Product Recycling ........................................................................................... 42
Appendix C: Troubleshooting .................................................................................43
Resetting the System .......................................................................................................... 43
Problems following Initial System Installation ...................................................................... 43
First Steps Checklist ................................................................................................... 44
Hardware Diagnostic Testing .............................................................................................. 44
Verifying Proper Operation of Key System Lights ....................................................... 45
Confirming Loading of the Operating System ............................................................. 45
Specific Problems and Corrective Actions .......................................................................... 45
Power Light Does Not Light ........................................................................................ 46
No Characters Appear on Screen ............................................................................... 46
Characters Are Distorted or Incorrect ......................................................................... 47
System Cooling Fans Do Not Rotate Properly ............................................................ 47
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light .............................. 48
Cannot Connect to a Server ........................................................................................ 48
Problems with Network ............................................................................................... 48
System Boots when Installing PCI Card ..................................................................... 49
Problems with Newly Installed Application Software ................................................... 49
Problems with Application Software that Ran Correctly Earlier .................................. 50
Devices are not Recognized under Device Manager (Windows* Operating System) . 50
xii Intel® Server Board S3000AH User’s Guide
Hard Drive(s) are not Recognized ...............................................................................50
Bootable CD-ROM Disk Is Not Detected .....................................................................51
LED Information ...........................................................................................................51
BIOS POST Beep Codes ............................................................................................52
Appendix D: Intel® Server Issue Report Form ....................................................... 53
Intel® Server Board S3000AH User’s Guide xiii
xiv Intel® Server Board S3000AH User’s Guide
List of Tables
Table 1. Additional Information and Software .........................................................................viii
Table 2. Server Board Features ................................................................................................2
Table 3. NIC LED Descriptions ...............................................................................................13
Table 4. Setup Menu Key Use ................................................................................................18
Table 5. Product Certification Markings ..................................................................................38
Table 6. Resetting the System ................................................................................................43
Table 7. LED Information ........................................................................................................51
Table 8. POST Error Beep Codes ...........................................................................................52
Intel® Server Board S3000AH User’s Guide xv
xvi Intel® Server Board S3000AH User’s Guide
List of Figures
Figure 1. Intel® Server Board S3000AH (S3000AHLX shown) ................................................. 1
Figure 2. Configuring SATA as RAID in BIOS Setup ................................................................ 4
Figure 3. S3000AHLX Connector and Component Locations................................................... 7
Figure 4. S3000AH Connector and Component Locations ....................................................... 9
Figure 5. S3000AHV Connector and Component Locations................................................... 11
Figure 6. Configuration Jumper Descriptions.......................................................................... 12
Figure 7. Back Panel Connectors............................................................................................ 13
Figure 8. CMOS Clear Jumper................................................................................................ 21
Figure 9. Installing Memory..................................................................................................... 24
Figure 10. Lifting the Socket Handle ....................................................................................... 26
Figure 11. Open the Load Plate .............................................................................................. 26
Figure 12. Removing the Shipping Cover ............................................................................... 27
Figure 13. Installing the Processor.......................................................................................... 27
Figure 14. Removing the Protective Socket Cover ................................................................. 27
Figure 15. Installing the Heat Sink .......................................................................................... 28
Figure 16. Replacing the Backup Battery................................................................................ 31
Intel® Server Board S3000AH User’s Guide xvii
xviii Intel® Server Board S3000AH User’s Guide
1 Server Board Features
This chapter briefly describes the main features of the Intel® Server Board S3000AH. This chapter provides a photograph of the product, a list of the server board features, and diagrams showing the location of important components and connections on the server board.
Figure 1. Intel
®
Server Board S3000AH (S3000AHLX shown)
Table 2 summarizes the features of the server board.
Table 2. Server Board Features
Feature Description
Processor Processor and Front Side Bus (FSB) support
®
Supports Dual-Core Intel
Supports Intel
®
Xeon
processor 3200 series, Intel® Pentium® processor Extreme Edition (S3000AHLX and S3000AH only), Intel Pentium LGA775 package
®
4 processors, and Intel® Celeron® D processors in the Intel®
®
dual-core technology
®
Xeon
processor 3000 series, Quad-Core Intel
®
Pentium® D processors, Intel®
Supports Hyper-Threading Technology
Supports Intel
Memory Four DIMM sockets supporting stacked DDR2 533/667 MHz ECC or non-ECC
unbuffered memory (up to 8 GB of total system memory)
Chipset Intel
®
3000 chipset, consisting of:
®
Intel
Intel
Intel
3000 Memory Controller Hub (MCH)
®
I/O Controller Hub (ICH7R)
®
6702 PXH-V PCI-X* Hub (S3000AHLX SKU only)
®
Extended Memory System 64 Technology (Intel® EM64T)
®
Peripheral Interfaces
External connections:
Stacked PS/2* ports for keyboard and mouse
DB9 Serial A port
Two RJ45 NIC connectors for 10/100/1000 Mb connections
Two USB 2.0 ports
Internal connections:
One USB port header, which supports two USB 2.0 ports
One DH10 Serial B header
Four Serial ATA connectors with embedded RAID 0/1/10 support for Intel
Embedded Server RAID Technology and RAID 0/1/5/10 for Intel Storage Technology
®
Matrix
One ATA-100 connector
ATX-compliant 24-pin control panel header
I/O Controll SMSC* SCH5027 controller
Video On-board ATI* ES1000 video controller with 16MB external video memory
Hard drive
ATA-100 support: one IDE channel capable of supporting up to two drives
SATA (3.0 Gb/s) support
LAN
®
Intel
Intel
10/100/1000 82573E Gigabit Ethernet Controller
®
10/100/1000 82541PI Gigabit Ethernet Controller (S3000AHLX/
S3000AH only)
®
2 Intel® Server Board S3000AH User’s Guide
Table 2. Server Board Features
Feature Description
Expansion Capabilities
S3000AHLX SKU:
Two full length 32-bit/33MHz, 3.3V Universal PCI connectors
One physical x4 PCI Express* connector (operating at x1 lane speed)
One full length PCI-X* connector (64-bit/133MHz)
One Intel
64-bit/133MHz add-in card)
S3000AH SKU:
®
Adaptive Slot connector (supports one PCIe* x8 or one PCI-X*
Two full length 32-bit/33MHz, 3.3V Universal PCI connectors
One x8 PCI Express* connector
One physical x4 PCI Express* connector (operating at x1 lane speed)
One physical x8 PCI Express* connector (operating at x4 lane speed)
S3000AHV SKU:
Two full length 32-bit/33MHz, 3.3V Universal PCI connectors
One x8 PCI Express* connector
One physical x8 PCI Express* connector (operating at x4 lane speed)
Fans Support for up to four system fans and one processor fan
System Management
®
Intel
System Management Software
Intel® Server Board S3000AH User’s Guide 3
RAID Support
The Intel® Server Board S3000AH provides SATA (3.0 Gb/s) support. For information on configuring RAID, see the RAID Software Guide that is included on
the Intel
®
Server Deployment Toolkit 2.0 CD.
SATA Server Board
The Intel® Server Board S3000AH provides an embedded SATA controller that supports both 1.5 and 3.0 Gbps data transfer rates.
The BIOS Setup utility provides multiple drive configuration options on the Advanced | ATA Controller setup page, some of which affect the ability to configure RAID. The “Onboard SATA Controller” option is enabled by default. When this option is enabled, the “SATA Mode” option can be set to either Legacy or Enhanced. The Legacy and Enhanced modes affect the RAID configuration as follows:
In Legacy mode, the BIOS can enumerate only four drives and does not provide
RAID support.
In Enhanced mode, the BIOS is not limited to legacy PATA four drive limitations
and can enumerate the two PATA drives and four SATA drives (totalling six drives). This mode is required for RAID configurations.
When the enhanced mode is selected, you can choose to “Configure SATA as RAID”. Under SATA RAID OPROM: choosing the LSI* option (Intel Technology) will enable RAID 0, 1, and 10 while choosing Intel Technology will enable RAID 0, 1, 5, and 10.
®
Embedded Server RAID
®
Matrix Storage
Figure 2. Configuring SATA as RAID in BIOS Setup
4 Intel® Server Board S3000AH User’s Guide
Notes: For assistance in navigating through the F2 BIOS Setup utility, see the Intel® Server
Board S3000AH Technical Product Specification. For information on setting up RAID, see the RAID Software Guide that is included on the
®
Intel
Server Deployment Toolkit 2.0 CD.
®
Matrix Storage Technology supports software SATA RAID 0, 1, 10, and 5.
Intel
Microsoft Windows* driv er su pp ort only.
®
Embedded Server RAID Technology and the LSI* Logic SATA controller support
Intel software SATA RAID 0, 1, and 10.
Driver support available for all supported operating systems.
Intel® Embedded Server RAID Technology
Intel® Embedded Server RAID Technology supports four Serial ATA ports, providing a cost-effective way to achieve higher transfer rates and reliability. Intel RAID Technology supports
RAID level 0 data striping for improved performance
RAID level 1 data mirroring for improved data reliability
RAID level 10 data striping and mirroring for high data transfer rates and data
redundancy
Intel® Matrix Storage Manager
Intel® Matrix Storage Manager provides software support for high-performance Serial ATA RAID 0 arrays, fault-tolerant Serial ATA RAID 1 arrays, high capacity and fault­tolerant Serial ATA RAID 5 arrays, and high performance and fault-tolerant Serial ATA RAID 10 arrays on supported chipsets using select operating systems. Intel Storage Manager is the software that enables Intel
For detailed information and supported OSes, please refer to the following website: http://support.intel.com/support/chipsets/imsm/
®
Embedded Server
®
®
Matrix Storage Technology.
Matrix
Intel® Server Board S3000AH User’s Guide 5
Loading...
+ 51 hidden pages