Intel S2600KPFR, S2600KPR Product Specifications

REVISION 1.37
APRIL 2017
INTEL® SERVER PRODUCTS AND SOLUTIONS
Intel® Server Board S2600KP Product Family and Intel® Compute Module HNS2600KP Product Family
Technical Product Specification
A document providing an overview of product features, functions, architecture, and support specifications
Revision History Technical Product Specification
Date
Revision Number
Modifications
September, 2014
1.00
1st External Public Release
January, 2015
1.10
Added 12G SAS bridge boards Updated BMC Sensor Table Removed Appendix Node Manager 2.0 IPMI Integrated Sensors Added POST Error Beep Codes
March, 2015
1.11
Added maximum RPM for BMC fan control
August, 2015
1.20
Corrected the InfiniBand* Connect-IB* name Removed the 6G SAS bridge board (option1) from the support list
November, 2015
1.21
Updated the product code Corrected pin-out tables references
March, 2016
1.30
Added support for Intel® Xeon® processor E5-2600 v4 product family Added AHWKPTP12GBGBIT
April, 2016
1.31
Added FXX2130PCRPS Power Supply
April, 2016
1.32
Added J6B4 jumper
May, 2016
1.33
Added BBS2600KPTR TPM references
June, 2016
1.34
Added H2312XXLR2 and H2216XXLR2 references
August, 2016
1.35
Updated embedded RAID description Updated 6Gbps Bridge Board description
October, 2016
1.36
Updated the E5-2600 v4 memory speed supported reference Added AXXKPTPM2IOM and M.2 device references Intel® ESRT2 SATA DOM support for RAID-0 and RAID-1 Typographical corrections
April, 2017
1.37
Added S2600KPFR Mellanox IB card has no driver support for Windows OS Errata: Removed “ED2 – 4: CATERR due to CPU 3-strike timeout” from
CATERR Sensor section
Revision History
ii Revision 1.37
Technical Product Specification Disclaimers
Disclaimers
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, lifesaving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.
A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES, SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS.
Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
The Intel® Server Board S2600KP Product Family and Intel® Compute Module HNS2600KP Product Familyproduct may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.
This document and the software described in it are furnished under license and may only be used or copied in accordance with the terms of the license. The information in this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Intel Corporation. Intel Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document or any software that may be provided in association with this document.
Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means without the express written consent of Intel Corporation.
Copies of documents which have an order number and are referenced in this document, or other Intel® Literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/Literature.htm.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © 2016 Intel Corporation. All rights reserved.
Revision 1.37 iii
Table of Contents Technical Product Specification
Table of Contents
1 Introduction ........................................................................................................................................ 1
1.1 Chapter Outline .................................................................................................................................... 1
1.2 Server Board Use Disclaimer .......................................................................................................... 2
2 Product Features Overview ............................................................................................................. 3
2.1 Components and Features Identification ................................................................................. 6
2.2 Rear Connectors and Back Panel Feature Identification .................................................... 7
2.3 Intel® Light Guided Diagnostic LED .............................................................................................. 8
2.4 Jumper Identification ........................................................................................................................ 8
2.5 Mechanical Dimension and Weight ............................................................................................. 9
2.6 Product Architecture Overview .................................................................................................. 10
2.7 Power Docking Board ..................................................................................................................... 13
2.8 Bridge Board ....................................................................................................................................... 14
2.8.1 6G SATA Bridge Board ................................................................................................................... 14
2.8.2 12G SAS Bridge Board with IT mode ....................................................................................... 15
2.8.3 12G SAS Bridge Board with RAID 0, 1 and 10 ...................................................................... 15
2.8.4 12G SAS Bridge Board with RAID 0, 1, 5 and 10 ................................................................. 16
2.9 Riser Card ............................................................................................................................................ 16
2.9.1 Riser Slot 1 Riser Card .................................................................................................................... 16
2.9.2 Riser Slot 2 Riser Card .................................................................................................................... 17
2.10 I/O Module Carrier ........................................................................................................................... 17
2.11 Compute Module Fans ................................................................................................................... 20
2.12 Air Duct ................................................................................................................................................. 20
2.13 Intel® RAID C600 Upgrade Key .................................................................................................... 21
2.14 Intel® Remote Management Module 4 (Intel® RMM4) Lite ................................................ 21
2.15 Breakout Board ................................................................................................................................. 22
2.16 System Software Overview .......................................................................................................... 23
2.16.1 System BIOS ....................................................................................................................................... 24
2.16.2 Field Replaceable Unit (FRU) and Sensor Data Record (SDR) Data ............................. 28
2.16.3 Baseboard Management Controller (BMC) Firmware ....................................................... 29
3 Processor Support.......................................................................................................................... 30
3.1 Processor Socket Assembly ........................................................................................................ 30
3.2 Processor Thermal Design Power (TDP) Support .............................................................. 31
3.3 Processor Population Rules ......................................................................................................... 31
3.4 Processor Initialization Error Summary .................................................................................. 32
3.5 Processor Function Overview ..................................................................................................... 35
iv Revision 1.37
Technical Product Specification Table of Contents
3.5.1 Processor Core Features ............................................................................................................... 35
3.5.2 Supported Technologies .............................................................................................................. 35
3.6 Processor Heat Sink ........................................................................................................................ 38
4 Memory Support ............................................................................................................................. 39
4.1 Memory Subsystem Architecture .............................................................................................. 39
4.1.1 IMC Modes of Operation ............................................................................................................... 40
4.1.2 Memory RASM Features ................................................................................................................ 41
4.2 Supported DDR4-2400 memory for Intel® Xeon processor v4 Product Family .... 42
4.3 Supported DDR4-2133 memory for Intel® Xeon processor v4 Product Family .... 43
4.4 Memory Slot Identification and Population Rules ............................................................. 43
4.5 System Memory Sizing and Publishing ................................................................................... 45
4.5.1 Effects of Memory Configuration on Memory Sizing ........................................................ 45
4.5.2 Publishing System Memory ......................................................................................................... 46
4.6 Memory Initialization ...................................................................................................................... 47
5 Server Board I/O ............................................................................................................................. 51
5.1 PCI Express* Support...................................................................................................................... 51
5.1.1 PCIe Enumeration and Allocation ............................................................................................. 51
5.1.2 PCIe Non-Transparent Bridge (NTB) ........................................................................................ 52
5.2 Add-in Card Support ...................................................................................................................... 53
5.2.1 Riser Card Support .......................................................................................................................... 53
5.3 Serial ATA (SATA) Support ........................................................................................................... 55
5.3.1 Staggered Disk Spin-Up ................................................................................................................ 57
5.4 Embedded SATA RAID Support ................................................................................................. 57
5.4.1 Intel® Rapid Storage Technology (RSTe) 4.0 ......................................................................... 57
5.4.2 Intel® Embedded Server RAID Technology 2 (ESRT2) ....................................................... 59
5.5 Network Interface ............................................................................................................................. 60
5.5.1 MAC Address Definition ................................................................................................................ 61
5.5.2 LAN Manageability ........................................................................................................................... 61
5.6 Video Support ................................................................................................................................... 61
5.7 Universal Serial Bus (USB) Ports ................................................................................................ 62
5.8 Serial Port ............................................................................................................................................ 63
5.9 InfiniBand* Adapter ......................................................................................................................... 63
5.9.1 Device Interfaces .............................................................................................................................. 64
5.9.2 Quad Small Form-factor Pluggable (QSFP+) Connector ................................................. 65
6 Connector and Header .................................................................................................................. 66
6.1 Power Connectors ........................................................................................................................... 66
6.1.1 Main Power Connector .................................................................................................................. 66
Revision 1.37 v
Table of Contents Technical Product Specification
6.1.2 Backup Power Connector ............................................................................................................. 66
6.2 System Management Headers .................................................................................................... 67
6.2.1 Intel® Remote Management Module 4 (Intel® RMM4) Lite Connector .......................... 67
6.2.2 IPMB Header ....................................................................................................................................... 67
6.2.3 Control Panel Connector .............................................................................................................. 67
6.3 Bridge Board Connector ................................................................................................................ 68
6.3.1 Power Button ..................................................................................................................................... 69
6.4 I/O Connectors .................................................................................................................................. 70
6.4.1 PCI Express* Connectors ............................................................................................................... 70
6.4.2 VGA Connector .................................................................................................................................. 78
6.4.3 NIC Connectors ................................................................................................................................. 79
6.4.4 SATA Connectors ............................................................................................................................. 79
6.4.5 SATA SGPIO Connectors ............................................................................................................... 80
6.4.6 Hard Drive Activity LED Header .................................................................................................. 80
6.4.7 Intel® RAID C600 Upgrade Key Connector ............................................................................. 80
6.4.8 Serial Port Connectors ................................................................................................................... 81
6.4.9 USB Connectors ................................................................................................................................ 81
6.4.10 QSFP+ for InfiniBand* .................................................................................................................... 82
6.4.11 UART Header ...................................................................................................................................... 82
6.5 Fan Headers ........................................................................................................................................ 83
6.5.1 FAN Control Cable Connector .................................................................................................... 83
6.5.2 Discrete System FAN Connector ................................................................................................ 83
6.6 Power Docking Board Connectors ............................................................................................ 84
6.7 Breakout Board Connector .......................................................................................................... 85
7 Configuration Jumpers ................................................................................................................. 86
7.1 PS All Node off (J6B4) .................................................................................................................... 87
7.2 BMC Force Update (J6B6)............................................................................................................. 87
7.3 ME Force Update (J5D2) ................................................................................................................ 88
7.4 Password Clear (J6B8) ................................................................................................................... 89
7.5 BIOS Recovery Mode (J6B9) ........................................................................................................ 90
7.6 BIOS Default (J6B7) ......................................................................................................................... 92
8 Intel® Light-Guided Diagnostics................................................................................................... 94
8.1 Status LED ........................................................................................................................................... 94
8.2 ID LED .................................................................................................................................................... 97
8.3 BMC Boot/Reset Status LED Indicators .................................................................................. 97
8.4 InfiniBand* Link/Activity LED ...................................................................................................... 98
8.5 POST Code Diagnostic LEDs ....................................................................................................... 98
vi Revision 1.37
Technical Product Specification Table of Contents
9 Platform Management ................................................................................................................. 100
9.1 Management Feature Set Overview ...................................................................................... 100
9.1.1 IPMI 2.0 Features Overview ...................................................................................................... 100
9.1.2 Non IPMI Features Overview .................................................................................................... 101
9.2 Platform Management Features and Functions ............................................................... 103
9.2.1 Power Subsystem ......................................................................................................................... 103
9.2.2 Advanced Configuration and Power Interface (ACPI) .................................................... 103
9.2.3 System Initialization ..................................................................................................................... 104
9.2.4 System Event Log (SEL) .............................................................................................................. 105
9.3 Sensor Monitoring ........................................................................................................................ 105
9.3.1 Sensor Scanning ............................................................................................................................ 105
9.3.2 Sensor Rearm Behavior .............................................................................................................. 105
9.3.3 BIOS Event-Only Sensors .......................................................................................................... 106
9.3.4 Margin Sensors ............................................................................................................................... 107
9.3.5 IPMI Watchdog Sensor ............................................................................................................... 107
9.3.6 BMC Watchdog Sensor ............................................................................................................... 107
9.3.7 BMC System Management Health Monitoring .................................................................. 107
9.3.8 VR Watchdog Timer ..................................................................................................................... 107
9.3.9 System Airflow Monitoring ........................................................................................................ 107
9.3.10 Thermal Monitoring ..................................................................................................................... 108
9.3.11 Processor Sensors ........................................................................................................................ 111
9.3.12 Voltage Monitoring ....................................................................................................................... 114
9.3.13 Fan Monitoring ............................................................................................................................... 114
9.3.14 Standard Fan Management ....................................................................................................... 116
9.3.15 Power Management Bus (PMBus*) ......................................................................................... 122
9.3.16 Power Supply Dynamic Redundancy Sensor .................................................................... 122
9.3.17 Component Fault LED Control ................................................................................................ 123
9.3.18 CMOS Battery Monitoring .......................................................................................................... 124
9.4 Intel® Intelligent Power Node Manager (NM)...................................................................... 124
9.4.1 Hardware Requirements ............................................................................................................ 124
9.4.2 Features ............................................................................................................................................. 125
9.4.3 ME System Management Bus (SMBus*) Interface............................................................ 125
9.4.4 PECI 3.0 ............................................................................................................................................. 125
9.4.5 NM “Discovery” OEM SDR .......................................................................................................... 125
9.4.6 SmaRT/CLST ................................................................................................................................... 125
9.5 Basic and Advanced Server Management Features ....................................................... 126
9.5.1 Dedicated Management Port ................................................................................................... 127
Revision 1.37 vii
Table of Contents Technical Product Specification
9.5.2 Embedded Web Server ............................................................................................................... 127
9.5.3 Advanced Management Feature Support (RMM4 Lite) ................................................. 129
10 Thermal Management ................................................................................................................. 134
11 System Security ............................................................................................................................ 136
11.1 Password Setup ............................................................................................................................. 136
11.1.1 System Administrator Password Rights .............................................................................. 137
11.1.2 Authorized System User Password Rights and Restrictions ....................................... 137
11.2 Front Panel Lockout ..................................................................................................................... 138
11.3 Trusted Platform Module (TPM) support ............................................................................ 138
11.3.1 TPM security BIOS ........................................................................................................................ 139
11.3.2 Physical presence ......................................................................................................................... 139
11.3.3 TPM security setup options ...................................................................................................... 139
12 Environmental Limits Specification ......................................................................................... 141
13 Power Supply Specification Guidelines .................................................................................. 142
13.1 Power Supply DC Output Connector .................................................................................... 142
13.2 Power Supply DC Output Specification ............................................................................... 142
13.2.1 Output Power/Currents .............................................................................................................. 142
13.2.2 Standby Output ............................................................................................................................. 143
13.2.3 Voltage Regulation ....................................................................................................................... 143
13.2.4 Dynamic Loading ........................................................................................................................... 143
13.2.5 Capacitive Loading ....................................................................................................................... 143
13.2.6 Grounding......................................................................................................................................... 144
13.2.7 Closed-loop Stability ................................................................................................................... 144
13.2.8 Residual Voltage Immunity in Standby Mode ................................................................... 144
13.2.9 Common Mode Noise .................................................................................................................. 144
13.2.10 Soft Starting .................................................................................................................................... 144
13.2.11 Zero Load Stability Requirements ......................................................................................... 145
13.2.12 Hot Swap Requirements ............................................................................................................. 145
13.2.13 Forced Load Sharing .................................................................................................................... 145
13.2.14 Ripple/Noise .................................................................................................................................... 145
13.2.15 Timing Requirement .................................................................................................................... 145
Appendix A: Integration and Usage Tips ........................................................................................ 149
Appendix B: Integrated BMC Sensor Tables .................................................................................. 150
Appendix C: BIOS Sensors and SEL Data ........................................................................................ 167
Appendix D: POST Code Diagnostic LED Decoder ....................................................................... 174
Appendix E: POST Code Errors ......................................................................................................... 181
POST Error Beep Codes .................................................................................................................................... 183
viii Revision 1.37
Technical Product Specification Table of Contents
Appendix F: Statement of Volatility ................................................................................................ 185
Glossary ................................................................................................................................................. 187
Reference Documents ......................................................................................................................... 189
Revision 1.37 ix
List of Figures Technical Product Specification
List of Figures
Figure 1. Intel® Server Board S2600KPFR (demo picture) ............................................................................. 3
Figure 2. Intel® Compute Module HNS2600KPR (demo picture) ................................................................ 3
Figure 3. Server Board Components (S2600KPFR).......................................................................................... 6
Figure 4. Compute Module Components ............................................................................................................. 6
Figure 5. Server Board Rear Connectors .............................................................................................................. 7
Figure 6. Compute Module Back Panel ................................................................................................................. 7
Figure 7. Intel® Light Guided Diagnostic LED ...................................................................................................... 8
Figure 8. Jumper Identification ................................................................................................................................ 8
Figure 9. Server Board Dimension .......................................................................................................................... 9
Figure 10. Compute Module Dimension ............................................................................................................... 9
Figure 11. Intel® Server Board S2600KPR Block Diagram .......................................................................... 11
Figure 12. Intel® Server Board S2600KPFR Block Diagram ........................................................................ 12
Figure 13. Intel® Server Board S2600KPTR Block Diagram ......................................................................... 13
Figure 14. Power Docking Board Overview ...................................................................................................... 14
Figure 15. 6G SATA Bridge Board Overview .................................................................................................... 15
Figure 16. 12G SAS Bridge Board with IT mode Overview ........................................................................ 15
Figure 17. 12G SAS Bridge Board with RAID 0, 1 and 10 Overview ....................................................... 16
Figure 18. 12G SAS Bridge Board with RAID 0, 1, 5 and 10 Overview .................................................. 16
Figure 19. Riser Card for Riser Slot #1 ............................................................................................................... 16
Figure 20. Riser Card for Riser Slot #2 ............................................................................................................... 17
Figure 21. I/O Module Carrier Installation ........................................................................................................ 17
Figure 22. Installing the M.2 Device .................................................................................................................... 18
Figure 23. AXXKPTPM2IOM I/O Module Carrier Connectors ................................................................... 18
Figure 24. Connecting the M.2 SATA cable ...................................................................................................... 19
Figure 25. Compute Module Fans ........................................................................................................................ 20
Figure 26. Air Duct ...................................................................................................................................................... 21
Figure 27. Intel® RAID C600 Upgrade Key ......................................................................................................... 21
Figure 28. Intel® RMM4 Lite ..................................................................................................................................... 22
Figure 29. Breakout Board Front and Rear View ............................................................................................ 23
Figure 30. Breakout Board Mechanical Drawing (Unit: mm)...................................................................... 23
Figure 31. Processor Socket Assembly .............................................................................................................. 30
Figure 32. Processor Socket ILM .......................................................................................................................... 30
Figure 33. Processor Heat Sink Overview ......................................................................................................... 38
Figure 34. Integrated Memory Controller Functional Block Diagram ................................................... 39
Figure 35. DIMM Slot Identification ..................................................................................................................... 44
x Revision 1.37
Technical Product Specification List of Figures
Figure 36. Add-in Card Support Block Diagram (S2600KPR) ................................................................... 53
Figure 37. Server Board Riser Slots (S2600KPFR) ......................................................................................... 53
Figure 38. SATA Support ......................................................................................................................................... 55
Figure 39. SATA RAID 5 Upgrade Key................................................................................................................. 59
Figure 40. Network Interface Connectors ......................................................................................................... 60
Figure 41. RJ45 NIC Port LED................................................................................................................................. 61
Figure 42. USB Ports Block Diagram ................................................................................................................... 63
Figure 43. Serial Port A Location .......................................................................................................................... 63
Figure 44. Jumper Location .................................................................................................................................... 86
Figure 45. Status LED (E) and ID LED (D) ........................................................................................................... 94
Figure 46. InfiniBand* Link LED (K) and InfiniBand* Activity LED (J) ..................................................... 98
Figure 47. Rear Panel Diagnostic LEDs .............................................................................................................. 99
Figure 48. High-level Fan Speed Control Process ...................................................................................... 119
Figure 49. Air Flow and Fan Identification ..................................................................................................... 134
Figure 50. Turn On/Off Timing (Power Supply Signals – 5VSB) ........................................................... 148
Figure 51. Turn On/Off Timing (Power Supply Signals – 12VSB) ........................................................ 148
Figure 52. Diagnostic LED Placement Diagram ........................................................................................... 174
Revision 1.37 xi
List of Tables Technical Product Specification
List of Tables
Table 1. Intel® Server Board S2600KP Product Family Feature Set .......................................................... 4
Table 2. Intel® Compute Module HNS2600KP Product Family Feature Set .......................................... 5
Table 3. Product Weight and Packaging ........................................................................................................... 10
Table 4. POST Hot-Keys ........................................................................................................................................... 26
Table 5. Mixed Processor Configurations Error Summary ......................................................................... 33
Table 6. DDR4-2400 DIMM Support Guidelines for Intel® Xeon processor v4 Product Family . 42
Table 8. DIMM Nomenclature ................................................................................................................................ 44
Table 9. Supported DIMM Populations .............................................................................................................. 44
Table 10. PCIe* Port Routing – CPU 1 ................................................................................................................ 54
Table 11. PCIe* Port Routing – CPU 2 ................................................................................................................ 54
Table 12. SATA and sSATA Controller BIOS Utility Setup Options ....................................................... 55
Table 13. SATA and sSATA Controller Feature Support ............................................................................ 56
Table 14. Onboard Video Resolution and Refresh Rate (Hz) .................................................................... 62
Table 15. Network Port Configuration ............................................................................................................... 64
Table 16. Main Power Supply Connector 6-pin 2x3 Connector .............................................................. 66
Table 17. Backup Power Connector .................................................................................................................... 66
Table 18. Intel® RMM4 Lite Connector ................................................................................................................ 67
Table 19. IPMB Header ............................................................................................................................................. 67
Table 20. Control Panel Connector ..................................................................................................................... 67
Table 21. Bridge Board Connector ...................................................................................................................... 68
Table 22. SATA DOM Connector Pin-out .......................................................................................................... 69
Table 23. USB 2.0 Type-A Connector Pin-out ................................................................................................ 70
Table 24. 5V_AUX Power Connector Pin-out.................................................................................................. 70
Table 25. CPU1 and CPU2 PCIe Bus Connectivity ......................................................................................... 70
Table 26. PCI Express* x16 Riser Slot 1 Connector ...................................................................................... 71
Table 27. PCI Express* x24 Riser Slot 2 Connector ...................................................................................... 73
Table 28. PCI Express* x24 Riser Slot 3 Connector ...................................................................................... 76
Table 29. PCI Express* Riser ID Assignment .................................................................................................... 78
Table 30. PCI Express* Clock Source by Slot .................................................................................................. 78
Table 31. VGA External Video Connector ......................................................................................................... 78
Table 32. RJ-45 10/100/1000 NIC Connector ............................................................................................... 79
Table 33. SATA Connector ...................................................................................................................................... 80
Table 34. SATA SGPIO Connector ....................................................................................................................... 80
Table 35. SATA HDD Activity LED Header ........................................................................................................ 80
Table 36. Storage Upgrade Key Connector ..................................................................................................... 81
xii Revision 1.37
Technical Product Specification List of Tables
Table 37. Internal 9-pin Serial A ........................................................................................................................... 81
Table 38. External USB port Connector............................................................................................................. 81
Table 39. Internal USB Connector ....................................................................................................................... 81
Table 40. QSFP+ Connector ................................................................................................................................... 82
Table 41. UART Header ............................................................................................................................................ 82
Table 42. Baseboard Fan Connector................................................................................................................... 83
Table 43. Baseboard Fan Connector................................................................................................................... 83
Table 44. Main Power Input Connector ............................................................................................................. 84
Table 45. Fan Control Signal Connector ........................................................................................................... 84
Table 46. Compute Module Fan Connector ..................................................................................................... 84
Table 47. Main Power Output Connector ......................................................................................................... 84
Table 48. Miscellaneous Signal Connector ...................................................................................................... 85
Table 49. Jumper Modes Selection ..................................................................................................................... 86
Table 50. PS All Node off (J6B4) .......................................................................................................................... 87
Table 51. Force Integrated BMC Update Jumper (J6B6) ............................................................................ 87
Table 52. Force ME Update Jumper (J5D2) ..................................................................................................... 88
Table 53. Password Clear Jumper (J6B8) ......................................................................................................... 90
Table 54. BIOS Recovery Mode Jumper (J6B9) ............................................................................................. 91
Table 55. BIOS Default Jumper ............................................................................................................................. 92
Table 56. Status LED State Definitions .............................................................................................................. 95
Table 57. ID LED .......................................................................................................................................................... 97
Table 58. BMC Boot/Reset Status LED Indicators ......................................................................................... 97
Table 59. InfiniBand* Link/Activity LED ............................................................................................................. 98
Table 60. ACPI Power States ............................................................................................................................... 103
Table 61. Processor Sensors ............................................................................................................................... 111
Table 62. Processor Status Sensor Implementation ................................................................................. 112
Table 63. Component Fault LEDs ...................................................................................................................... 123
Table 64. Intel® Remote Management Module 4 (RMM4) Options ...................................................... 126
Table 65. Basic and Advanced Server Management Features Overview .......................................... 127
Table 66. Air Flow .................................................................................................................................................... 134
Table 67. TPM Setup Utility – Security Configuration Screen Fields ................................................. 140
Table 68. Server Board Design Specifications ............................................................................................. 141
Table 69. Power Supply DC Power Input Connector Pin-out ................................................................ 142
Table 70. Minimum 1200W/1600W Load Ratings..................................................................................... 142
Table 71. Minimum 2130W Load Ratings ...................................................................................................... 142
Table 72. Voltage Regulation Limits ................................................................................................................ 143
Table 73. Transient Load Requirements ........................................................................................................ 143
Revision 1.37 xiii
List of Tables Technical Product Specification
Table 74. Capacitive Loading Conditions ....................................................................................................... 144
Table 75. Ripples and Noise ................................................................................................................................ 145
Table 76. Timing Requirements ......................................................................................................................... 146
Table 77. Timing Requirements (12VSB) ....................................................................................................... 147
Table 78. BMC Sensor Table ............................................................................................................................... 152
Table 79. BIOS Sensor and SEL Data ............................................................................................................... 167
Table 80. POST Code LED Example ................................................................................................................. 175
Table 81. MRC Fatal Error Codes ....................................................................................................................... 175
Table 82. MRC Progress Codes .......................................................................................................................... 176
Table 83. POST Progress Codes ........................................................................................................................ 177
Table 84. POST Error Codes and Messages.................................................................................................. 181
Table 85. POST Error Beep Codes .................................................................................................................... 183
Table 86. Glossary ................................................................................................................................................... 187
xiv Revision 1.37
Technical Product Specification List of Tables
<This page is intentionally left blank.>
Revision 1.37 xv
Technical Product Specification Introduction
1 Introduction
This Technical Product Specification (TPS) provides specific information detailing the features, functionality, and high-level architecture of the Intel® Server Board S2600KP product family and the Intel® Compute Module HNS2600KP product family.
Design-level information related to specific server board components and subsystems can be obtained by ordering External Product Specifications (EPS) or External Design Specifications (EDS) related to this server generation. EPS and EDS documents are made available under NDA with Intel and must be ordered through your local Intel representative. See the Reference Documents section for a list of available documents.
1.1 Chapter Outline
This document is divided into the following chapters:
Chapter 1 – Introduction Chapter 2 – Product Features Overview Chapter 3 – Processor Support Chapter 4 – Memory Support Chapter 5 – Server Board I/O Chapter 6 – Connector and Header Chapter 7 – Configuration Jumpers Chapter 8 – Intel Chapter 9 – Platform Management Chapter 10 – Thermal Management Chapter 11 – System Security Chapter 12 – Environmental Limits Specification Chapter 13 – Power Supply Specification Guidelines Appendix A – Integration and Usage Tips Appendix B – Integrated BMC Sensor Tables Appendix C – BIOS Sensors and SEL Data Appendix D – POST Code Diagnostic LED Decoder Appendix E – POST Code Errors
®
Light-Guided Diagnostics
Appendix F – Statement of Volatility Glossary Reference Documents
Revision 1.37 1
Introduction Technical Product Specification
2
1.2 Server Board Use Disclaimer
Intel Corporation server boards contain a number of high-density VLSI (Very Large Scale Integration) and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
Revision 1.37
Technical Product Specification Product Features Overview
2 Product Features Overview
The Intel® Server Board S2600KP product family is a monolithic printed circuit board (PCB) assembly with features designed to support the high performance and high density computing markets. This server board is designed to support the Intel® Xeon® processor E5­2600 v3/v4 product family. Previous generation Intel® Xeon® processors are not supported.
The Intel® Server Board S2600KP product family contains two server board options. Many of the features and functions of the server board family are common. A board will be identified by its name which has described features or functions unique to it.
S2600KPFR – With onboard InfiniBand* controller providing one external rear QSFP+
port
Figure 1. Intel® Server Board S2600KPFR (demo picture)
S2600KPR – Without onboard InfiniBand* controller, no external rear QSFP+ port
The Intel® Compute Module HNS2600KP product family provides two compute module options, each integrated with either of the server board from the Intel® Server Board S2600KP product family.
Figure 2. Intel® Compute Module HNS2600KPR (demo picture)
Revision 1.37 3
Product Features Overview Technical Product Specification
4
Feature
Description
Processor Support
Two LGA2011-3 (Socket R3) processor sockets Support for one or two Intel
®
Xeon® processors E5-2600 v3/v4
product family
Maximum supported Thermal Design Power (TDP) of up to 160 W
Memory Support
Eight DIMM slots in total across eight memory channels Registered DDR4 (RDIMM), Load Reduced DDR4 (LRDIMM) Memory DDR4 data transfer rates of 1600/1866/2133/2400 MT/s
Chipset
Intel® C612 chipset
External I/O Connections
DB-15 video connector Two RJ-45 1GbE Network Interface Controller (NIC) ports One dedicated RJ-45 port for remote server management One stacked two port USB 2.0 (port 0/1) connector One InfiniBand* FDR QSFP+ port (S2600KPFR only)
Internal I/O connectors/headers
Bridge slot to extend board I/O
o Four SATA 6Gb/s signals to backplane o Front control panel signals o One SATA 6Gb/s port for SATA DOM o One USB 2.0 connector (port 10)
One internal USB 2.0 connector (port 6/7) One 2x7 pin header for system fan module One 1x12 pin control panel header One DH-10 serial Port A connector One SATA 6Gb/s port for SATA DOM Four SATA 6Gb/s connectors (port 0/1/2/3) One 2x4 pin header for Intel
®
RMM4 Lite
One 1x4 pin header for Storage Upgrade Key One 1x8 pin backup power connector
PCIe Support
PCIe* 3.0 (2.5, 5, 8 GT/s)
Power Connections
Two sets of 2x3 pin connectors (main power 1/2)
System Fan Support
One 2x7 pin fan control connector for Intel compute module and
chassis
Three 1x8 pin fan connectors for third-party chassis
Video
Integrated 2D video graphics controller 16MB DDR3 memory
Riser Support
Three riser slots
o Riser slot 1 provides x16 PCIe* 3.0 lanes o Riser slot 2 provides
x24 PCIe* 3.0 lanes for S2600KPR x16 PCIe* 3.0 lanes for S2600KPFR
o Riser slot 3 provides x24 PCIe* 3.0 lanes
One bridge board slot for board I/O expansion
The following table provides a high-level product feature list.
Table 1. Intel® Server Board S2600KP Product Family Feature Set
Revision 1.37
Technical Product Specification Product Features Overview
Feature
Description
On-board storage controllers and options
5 on-board SATA 6Gb/s ports, one of them is SATA DOM compatible. 5 SATA 6Gb/s signals to backplane via bridge slot.
RAID Support
Intel
®
Rapid Storage RAID Technology (RSTe) 4.0
Intel
®
Embedded Server RAID Technology 2 (ESRT2) with optional
Intel® RAID C600 Upgrade Key to enable SATA RAID 5
Server Management
Onboard Emulex* Pilot III* Controller Support for Intel
®
Remote Management Module 4 Lite solutions
Intel
®
Light-Guided Diagnostics on field replaceable units
Support for Intel
®
System Management Software
Support for Intel
®
Intelligent Power Node Manager (Need
PMBus*-compliant power supply)
Security
Intel® Trusted Platform Module (TPM) v1.2 for BBS2600KPTR only
Feature1
Description
Server Board
Intel® Server Board S2600KP product family
HNS2600KPR – include Intel
®
Server Board S2600KPR
HNS2600KPFR – include Intel
®
Server Board S2600KPFR
Processor Support
Maximum supported Thermal Design Power (TDP) of up to 145 W
Heat Sink
One Cu/Al 91.5x91.5mm heat sink for CPU 1 One Ex-Al 91.5x91.5mm heat sink for CPU 2
Fan
Three sets of 40x56mm dual rotor system fans
Riser Support
One riser card with bracket on riser slot 1 to support one PCIe* 3.0
x16 low profile card (default)2
One I/O module riser and carrier kit on riser slot 2 to support an
Intel® I/O Expansion Module (optional)
Note: Riser slot 3 cannot be used with the bridge board installed.
Compute Module Board
Three types of bridge boards:
o 6G SATA Bridge Board (Default) o 12G SAS Bridge Board (Optional) o 12G SAS Bridge Board with RAID 5 (Optional)
One compute module power docking board
Air Duct
One transparent air duct
Warning! The riser slot 1 on the server board is designed for plugging in ONLY the riser card. Plugging in any PCIe* card may cause permanent server board and PCIe* card damage.
Table 2. Intel® Compute Module HNS2600KP Product Family Feature Set
Notes:
1. The table only lists features that are unique to the compute module or different from the
server board.
Revision 1.37 5
Product Features Overview Technical Product Specification
6
2. ONLY low profile PCIe* card can be installed on riser slot 1 riser card of the compute
module.
2.1 Components and Features Identification
This section provides a general overview of the server board and compute module, identifying key features and component locations. The majority of the items identified are common in the product family.
Figure 3. Server Board Components (S2600KPFR)
Figure 4. Compute Module Components
Revision 1.37
Technical Product Specification Product Features Overview
Description
Description
A
NIC port 1 (RJ45)
G
Dedicated Management Port (RJ45)
B
NIC port 2 (RJ45)
H
InfiniBand* Port (QSFP+, S2600KPFR only)
C
Video out (DB-15)
I
POST Code LEDs (8 LEDs)
D
ID LED
J
InfiniBand* Activity LED (S2600KPFR only)
E
Status LED
K
InfiniBand* Link LED (S2600KPFR only)
F
Dual port USB
2.2 Rear Connectors and Back Panel Feature Identification
The Intel® Server Board S2600KP product family has the following board rear connector placement.
Figure 5. Server Board Rear Connectors
The Intel® Compute Module HNS2600KP product family has the following back panel features.
Figure 6. Compute Module Back Panel
Revision 1.37 7
Product Features Overview Technical Product Specification
8
2.3 Intel
®
Light Guided Diagnostic LED
Figure 7. Intel® Light Guided Diagnostic LED
2.4 Jumper Identification
Figure 8. Jumper Identification
Revision 1.37
Technical Product Specification Product Features Overview
2.5 Mechanical Dimension and Weight
Figure 9. Server Board Dimension
Figure 10. Compute Module Dimension
Revision 1.37 9
Product Features Overview Technical Product Specification
10
Product Code
Quantity per Box
Box Dimension (mm)
Net Weight
Package Weight
BBS2600KPR
10
553X242X463
10.0 kg
12.8 kg
BBS2600KPFR
10
553X242X463
10.4 kg
13.2 kg
BBS2600KPTR
10
553X242X463
0.98 kg
12.6 kg
HNS2600KPR
1
716X269X158
3.4 kg
4.6 kg
HNS2600KPFR
1
716X269X158
3.44 kg
4.64 kg
Approximate product weight is listed in the following table for reference. Variations are expected with real shipping products.
Table 3. Product Weight and Packaging
2.6 Product Architecture Overview
The Intel® Server Board S2600KP product family is a purpose built, rack-optimized, liquid cooling friendly server board used in a high-density rack system. It is designed around the integrated features and functions of the Intel® Xeon® processor E5-2600 V3/V4 product family, the Intel® C612 chipset, and other supporting components including the Integrated BMC, the Intel® I350 network interface controller, and the Mellanox* Connect-IB* adapter (S2600KPFR only).
The half-width board size allows four boards to reside in a standard multi-compute module 2U Intel® Server Chassis H2000G product family, for high-performance and high-density computing platforms.
The following diagram provides an overview of the server board architecture, showing the features and interconnects of each of the major subsystem components.
Revision 1.37
Technical Product Specification Product Features Overview
Figure 11. Intel® Server Board S2600KPR Block Diagram
Revision 1.37 11
Product Features Overview Technical Product Specification
12
Figure 12. Intel® Server Board S2600KPFR Block Diagram
Revision 1.37
Technical Product Specification Product Features Overview
Label
Description
A
2x7-pin fan control connector
Figure 13. Intel® Server Board S2600KPTR Block Diagram
The Intel® Compute Module HNS2600KP product family provides a series of features including the power docking board, bridge boards, riser cards, fans, and the air duct.
2.7 Power Docking Board
The power docking board provides hot swap docking of 12V main power between the compute module and the server. It supports three dual rotor fan connections, 12V main power hot swap controller, and current sensing. The power docking board is intended to support the usage of the compute module with the Intel® Server Board S2600KP product family.
Revision 1.37 13
Product Features Overview Technical Product Specification
14
B
8-pin connector for fan 1
C
2x6-pin main power output connector
D
8-pin connector for fan 2
E
12-pin connector for main power input
F
8-pin connector for fan 3
Label
Description
A
2x40-pin card edge connector (to the backplane)
B
USB 2.0 Type-A connector
C
2-pin 5V power
D
SATA DOM port connector
Figure 14. Power Docking Board Overview
2.8 Bridge Board
There are four types of bridge boards that implement different features and functions.
6G SATA bridge board (Default) 12G SAS bridge board with IT mode (Optional) 12G SAS bridge board with RAID 0, 1 and 10 (Optional) 12G SAS bridge board with RAID 0, 1, 5 and 10 (Optional)
Note: All 12G SAS bridge boards require two processors installed to be functional.
2.8.1 6G SATA Bridge Board
The 6G SATA bridge board provides hot swap interconnect of all electrical signals to the backplane of the server chassis (except for main 12V power). It supports up to 4x lanes of SATA, a 7-pin SATA connector for SATA DOM devices, and a type-A USB connector for USB flash device. One bridge board is used per one compute module. The bridge board is secured with screws to the compute module. The bridge board support embedded SATA RAID
Support.
Revision 1.37
Loading...
+ 175 hidden pages