Integra eplus 450, eplus 650, eplus 850 User Manual

1009-eplus450-850-en - 1
DO NOT connect laser printers, scanners, or copiers to this UPS. High power devices may damage this UPS.
________________________________________________________________________________________________________
1. SAFETY INSTRUCTIONS
SAFETY AND USE:
WARNING: This product has been designed to operate safely and reliably for years. Nevertheless, as it is an electrical
device, it is required to read and understand this manual. Keep manuals as references for future consults. WARNING: This product has been designed to be used indoors, protected of water, direct sun light and extreme temperatures. This device must not be used outdoors, close to moisture of heat sources.
WARNING: Do not set objects on this UPS. Handle with care. Do not block UPS ventilation. WARNING: Make sure to connect this unit to proper power line according to selected model. The UPS Technical Specs
sticker shows power rating information. DO NOT connect this UPS to any of its own power outlets. WARNING: UPS must be installed following instruction from this manual. The manufacturer is not liable for any damage that might rise from misusing this unit or defective installation. WARNING: Only computer related equipment can be connected to this UPS. DO NOT connect medical equipments, life support equipments, microwave ovens, vacuum cleaners, refrigerators, or any other appliance to this UPS.
WARNING: UPS must be checked, repaired and maintained by qualified personnel only. This product is locked by screws.
WARNING – ELECTRIC SHOCK RISK:
Inside the UPS there are dangerous high voltages even when disconnected of power line, due to internal batteries
WARNING: In case of emergency turn off the UPS pressing Power Button, unplug it and call technical support.
DISPOSAL – Out of order units:
Disposal
We strongly recommend disposing this UPS according to regulations in your country to prevent possible environmental damages; besides some parts might be recycled. BATTERY WARNING: DO NOT dispose batteries in fire as it might explode. DO NOT try to open batteries, there are dangerous liquids inside.
2. PRODUCT DESCRIPTION
EPLUS 450 / 650 / 850 series includes voltage regulation (Interactive Technology) ideal to protect computer related equipment at home and offices.
Power Outlets AC Input Input Breaker RJ11 / RJ45 USB
1009-eplus450-850-en - 2
First Time:
CHARGE BATTERIES FOR 6 HOURS BEFORE CONNECTING YOUR EQUIPMENTS TO UPS
3. INSTALLATION
This product leaves factory with battery fully charged, however
during transportation and storage it may loose a non determined part of its charge; therefore we recommend plugging it to Power Line for 6 hours before using the UPS.
Install this unit in any protected environment with a dust free
air flow. Also corrosive vapours and conductive contaminants must be avoided. Do not use UPS outdoors or where either temperature or humidity exceeds tech specs. Install UPS at least 10 inches away from your monitor to avoid magnetic interference.
Connect phone or LAN cable to RJ11/45 Jack Identified as
“IN” and your Router or PC RJ45 port to RJ-11/45 Jack Identified as “OUT”. Plug UPS to a power outlet with a proper grounding.
Connect your equipments to UPS power outlets.
NEVER connect equipments with power consumption higher
than Power Capacity of this UPS, such as Laser Printers or copiers.
4. OPERATION
For you to get higher performance of this UPS, it is important to understand how it works. This is an interactive UPS and protects your computer related equipments as well as your valuable information. When
minor power failures occurs (electrical surges or sags), your UPS quickly regulates voltage by means of its voltage stabilization without using batteries. When failure slips out of the UPS regulation range (as in a black out), UPS inverter starts working to generate power from energy stored in the batteries so you can properly close all applications, save your data and close operating system.
Under normal conditions, your UPS keeps charged and standing by. This unit is equipped with a LED indicator to let you know about UPS status. Power pushbutton is located in UPS front panel. To power up your UPS press power pushbutton once during 1 second.
To power off your UPS press power pushbutton again for 2 to 3 seconds.
Cold start function allows you to power up your UPS and your equipments even during power loss, thus your UPS acts
like a small power generator
5. MONITORING AND CONTROL SOFTWARE
Our software offers great features to communicate your PC and UPS, allowing an effective management of UPS capabilities. Among others, main software features are:
Programmable operation Interface On AC Power Failure, closes appropriately all applications and files saving all data Allows to schedule automatic UPS shutdown Graphically shows UPS status
Software Downloading Procedure: Go to www.integra-ups.com and select download section. Choose the appropriate version of “VIEWPOWER” according to your Operative System.
PASSWORD: To access as administrator the password to be used is: administrator VERY IMPORTANT: Download installation and operation manual as well; follow all instructions.
Loading...