Compact Digital Storage
Oscilloscope & Digital Multimeter
GW INSTEK PART NO. 82DS-22000MA1
ISO-9001 CERTIFIED MANUFACTURER
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

This manual contains proprietary information, which is
protected by copyright. All rights are reserved. No part
of this manual may be photocopied, reproduced or
translated to another language without prior written
consent of Good Will Corporation.
The information in this manual was correct at the time
of printing. However, Good Will continues to improve
its products and therefore reserves the right to change
the specifications, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng
Dist., New Taipei City 236, Taiwan.

SAFETY INSTRUCTIONS
Warning: Identifies conditions or
practices that could result in injury or
loss of life.
Caution: Identifies conditions or
practices that could result in damage
to the instrument or to other
properties.
Attention Refer to the Manual
Do not dispose electronic equipment
as unsorted municipal waste. Please
use a separate collection facility or
contact the supplier from which this
instrument was purchased.
The internal battery is not userreplaceable. Please return the unit back
to your local dealer for assistance. For
battery details, see the user manual.
This section contains the basic safety symbols that may
appear on the accompanying User Manual CD or on the
instrument. For detailed safety instructions and
precautions, please see the Safety Instructions chapter
in the user manual CD.
Safety Symbols
These safety symbols may appear in the user manual or
on the instrument.

Power Cord for the United Kingdom
When using the instrument in the United Kingdom,
make sure the power cord meets the following safety
instructions.
NOTE: This lead/appliance must only be wired by
competent persons.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in
accordance with the following code:
As the colours of the wires in main leads may not correspond with
the coloured marking identified in your plug/appliance, proceed as
follows:
The wire which is coloured Green & Yellow must be connected to
the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal
marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or
contact the supplier.
This cable/appliance should be protected by a suitably rated and
approved HBC mains fuse: refer to the rating information on the
equipment and/or user instructions for details. As a guide, a cable of
0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors
would normally require 13A types, depending on the connection
method used.
Any exposed wiring from a cable, plug or connection that is engaged
in a live socket is extremely hazardous. If a cable or plug is deemed
hazardous, turn off the mains power and remove the cable, any
fuses and fuse assemblies. All hazardous wiring must be
immediately destroyed and replaced in accordance to the above
standard.

GETTING STARTED
• 1 G Sa/s sampling rate max
• 70/100/200MHz bandwidth
• Acquisition memory: 1Mpts (GDS-
200), 5Mpts (GDS-300)
• Max 300Vrms(CAT II, DSO);
600V(CAT II) or 300V(CAT III) for
DMM
• 30,000 waveforms can be replayed
The Getting started chapter introduces the series lineup,
main features, appearance, and set up procedure.
Series Lineup
There are 6 models in the series, divided by DSO
bandwidth, DSO memory depth and DMM digit
resolution.

• Simultaneous DMM and DSO
operation
• Portrait and landscape modes
• Large 800 x 480 TFT panel and
capacitive touch panel
• 7.4V/6100mAH battery for up to 4
hours operation
• Support for differential probes
• Handy APPs - EE calculator, chip
resistance calculator, attenuation
calculator
• Shielded BNC terminals
• DSO Features
• X-Y mode
• Go/No Go
• 36 automatic measurement functions
• Trend plot
• Edge, Alt, Video and Pulse trigger
functions
• FFT, FFTrms, +, -, /, * math functions
• Replay function
• DMM Features
• 50,000 counts
• DCV, DCA, ACV, ACA, R, Diode,
Continuity, Temperature
• Fuse protection for the current ports

Package Contents and Accessories
Quick Start Guide (this document)
100MHz passive probe; for GDS207 /307, GDS-210 /310
200MHz passive probe; for GDS220 /320
GTP-200A-4
Multimeter test lead x2
Soft carrying case (large)
Dual-channel differential probe,
Only for GDS-200/300
GDP-040D
Type A - Mini-B USB cable
Vertical calibration cable