This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will Corporation.
The information in this manual was correct at the time of printing. However, Good Will continues to improve its products and therefore reserves the right to change the specifications, equipment, and maintenance procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
SAFETY INSTRUCTIONS
Warning
Warning: Identifies conditions or practices that could result in injury or loss of life.
Caution
Caution: Identifies conditions or practices that could result in damage to the instrument or to other properties.
DANGER High Voltage
Attention Refer to the Manual
Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased.
Battery Caution
The internal battery is not user­replaceable. Please return the unit back to your local dealer for assistance. For battery details, see the user manual.
This section contains the basic safety symbols that may appear on the accompanying User Manual CD or on the instrument. For detailed safety instructions and precautions, please see the Safety Instructions chapter in the user manual CD.
Safety Symbols
These safety symbols may appear in the user manual or on the instrument.
Power Cord for the United Kingdom
Green/ Yellow:
Earth Blue:
Neutral
Brown:
Live (Phase)
When using the instrument in the United Kingdom, make sure the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons.
WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code:
As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows: The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black. The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red. If in doubt, consult the instructions provided with the equipment or contact the supplier. This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of
0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous wiring must be immediately destroyed and replaced in accordance to the above standard.
GETTING STARTED
Model Name
Bandwidth
Memory Depth
DMM Resolution
Temp. Meas.
GDS-207
70MHz
1M points per channel
No
GDS-210
100MHz
GDS-220
200MHz
GDS-307
70MHz
5M points per channel
Yes
GDS-310
100MHz
GDS-320
200MHz
Performance
1 G Sa/s sampling rate max
70/100/200MHz bandwidth
Acquisition memory: 1Mpts (GDS-
200), 5Mpts (GDS-300)
Max 300Vrms(CAT II, DSO);
600V(CAT II) or 300V(CAT III) for DMM
30,000 waveforms can be replayed
The Getting started chapter introduces the series lineup, main features, appearance, and set up procedure.
Series Lineup
There are 6 models in the series, divided by DSO bandwidth, DSO memory depth and DMM digit resolution.
Features
Simultaneous DMM and DSO
operation
Portrait and landscape modes
Large 800 x 480 TFT panel and
capacitive touch panel
7.4V/6100mAH battery for up to 4
hours operation
Support for differential probes
Handy APPs - EE calculator, chip
resistance calculator, attenuation calculator
Shielded BNC terminals
DSO Features
X-Y mode
Go/No Go
36 automatic measurement functions
Trend plot
Edge, Alt, Video and Pulse trigger
functions
FFT, FFTrms, +, -, /, * math functions
Replay function
DMM Features
50,000 counts
DCV, DCA, ACV, ACA, R, Diode,
Continuity, Temperature
Fuse protection for the current ports
Interface
Mini-B USB device port
Package Contents and Accessories
Standard Accessories
Item
Part Number
User Manual CD
82DS-2200E01
Quick Start Guide (this document)
82DS-22000M01
100MHz passive probe; for GDS­207 /307, GDS-210 /310
GTP-100A-4
200MHz passive probe; for GDS­220 /320
GTP-200A-4 Multimeter test lead x2
GTL-207
Soft carrying case (large)
GSC-010
Protection bag (small)
GSC-011
Wrist strap
GWS-001
Optional Accessories
Item
Part Number
Dual-channel differential probe, Only for GDS-200/300
GDP-040D Type A - Mini-B USB cable
GTL-253
Vertical calibration cable
GCL-001
Download
Item
Part Number
USB driver
dso_vpo.inf
Loading...