MTS components:
LMA-3: Auxiliary Input #3 (AuxBox- RPM, Temp,
Duty Cycle, Acceleration, Boost/MAP): #3742
LC-1 (Lambda Cable): #3769
Stainless Steel Bung w/ Steel Plug” #3736
HBX-1: Heat-sinking Bung Extender: #3729
Replacement Parts:
Terminator Plug: #3750
MTS 2.5mm to 2.5mm serial cable: #3760
Serial Programming Cable: #3746
Order parts, get support, find FAQ answers, and read case
studies at www.tuneyourengine.com
XD-1
QUICK START GUIDE
The complete instruction manual is on the CD
Warning!
1) The Oxygen Sensor used with this device gets very hot in
operation. Do not touch the hot sensor. Do not let a hot sensor
touch a combustible surface. Do not use the sensor with or near
flammable liquids or gases. Failure to heed these warnings may
result in severe burns, explosions or fires. 2) When installed in
the exhaust, the oxygen sensor MUST be connected and
operating with the wideband controller whenever the car is
running. An un-powered oxygen sensor will be quickly damaged
when exposed to hot exhaust gases.
Warning!
1) The Oxygen Sensor used with this device gets very hot in operation. Do not touch
the hot sensor or let a hot sensor touch a combustible surface. 2) When installed in
the exhaust, the oxygen sensor MUST be connected and operating with the wideband
controller whenever the car is running. An un-powered oxygen sensor will be quickly
damaged.
The complete instruction manual is on the CD
XD-1
QUICK START GUIDE
1. If not using a gauge pod, cut a 52mm hole into the intended dash
location.
2. Insert and mount the XD-1 with the included mounting bracket,
leaving the XD-1 cables in the back accessible.
3. Connect the RED wire from the back of the XD-1 to a switched
12V source in your car. A switched 12V source is powered as soon
as the ignition on the car is on or the engine runs. Make sure the
connection is fused with at least a 2A fuse. Connect the BLACK
wire from the back of the XD-1 to a chassis ground.
4. If connecting to a LM-1, connect the “XD-1 to LM-1 cable” to the
LM-1’s Serial Port. Plug the 2.5mm male stereo end into the XD-1
Serial IN port (female 2.5 mm socket marked “IN”).
5. If connecting to an LC-1 or LMA-3, connect the male to male
2.5mm Stereo cable between the Serial OUT port of the LC-1 or
the LMA-3 to the Serial IN port of the XD-1.
6. If using a computer to data log or download LM-1 data, connect
the XD-1 to Computer cable between the Serial OUT port of the
XD-1 and the computer’s serial port
The following diagram show how to connect multiple Innovate
Motorsports devices to form a logging and display chain. The example
chain consists of a LM-1, a LC-1, a LMA-3 and 2 XD-1’s. In this case
the chain has 12 channels (6 from LM-1, 1 from LC-1 and 5 from LMA-
3).
Tips/Tricks
1. Initiating a free air calibration
Press the Control button three times rapidly. The display will show a
blinking:
Pressing the Control button while the blinking CAL is displayed will
initiate a free air calibration on ALL connected wideband devices.
If the button was press accidentally three times, wait for 5 seconds.
The XD-1 will return to normal display mode.
2. Start/Stop Recording
When the XD-1 is used with the LM-1, press the Control button once to
start recording. The Record indicator light will blink. Press the Control
button again to stop recording. The Record indictor will switch off.
To gain access to the complete XD-1 manual please
install the software provided on the CD which was
included as part of your kit. The manual will contain
important information such as configuration, programming, and
other tips & tricks.