G2, G4 & G5 Gauge Manual
Please follow the instructions that came with your wideband (LC-1, LC-2, or LM-2) prior to installing the gauge.
ALWAYS WEAR SAFETY GLASSES.
Install gauge only when engine is cool and ignition is off.
Make sure all necessary tools, materials, and parts are on hand.
Disconnect negative (-) battery cable before installing gauge.
Fig 1. Gauge Wiring Diagram
2-1/16" gauge mounts in a 2-1/16" diameter hole.
Make sure mounting location does not impair visibility or interfere with
driving. Also check behind the mounting location for any wiring or
components before drilling.
Table 1. Wiring Summary
Color Pin Connector Notes
12V+ (Battery) Purple 1 4 Connect to a 12V+ source that is always on, even when ignition is OFF (i.e. Battery +)
White Light White 2 4 Connect to 12V+ dash lighting for white backlight.
Ground Black 3 4 Connect to a good common ground.
Amber Light Orange 4 4 Connect to 12V+ dash lighting for amber backlight.
12V+ ACC (Ignition) Red 5 4 Connect to 12V+ ignition circuit so power is ON when ignition is turned on.
Not Used Red 1 3 Not used. Cut and seal wire.
Not Used Black 2 3 Not used. Cut and seal wire.
Signal Green 3 3 LC-1: Connect to the LC-1’s BROWN wire.
Menu Button + Red 1 2 Connect to red MENU button wire.
Menu Button - Black 2 2 Connect to black MENU button wire.
Not Used Green 3 2 Not used.
Warning Output + Red 1 1 Normal operating mode: 0V output. Warning mode: 12V output.
Warning Output - Black 2 1 Ground for warning output.
LC-2: Connect to the LC-2’s YELLOW wire.
LM-2: Connect to the LM-2’s Lime Green Wire, connect the LM-2’s yellow wire to the
same ground as the gauge.
1
Wiring
Use 20 AWG stranded or heavier wire for installation. Route wires away from
any moving parts and hot engine components. Secure wires firmly along their
route. Cut and seal all unused wire connections.
Note: As a safety precaution, the RED (Pin 5) and PURPLE (Pin 1) 12V+
connections should be fused. We recommend using a 1 Amp, 3 AG fast-acting
type cartridge fuse.
MENU Button Installation (Optional)
Installation of the remote MENU button is only necessary if you want to use the
RECALL and WARNING features of the gauge. Installation of the MENU
button is NOT required if you do not wish to use the RECALL or WARNING
features.
Mount the included MENU button in a location that is convenient. Connect the
red wire from the button to Connector 2, Pin 1 (Red) and the black wire on the
button to Connector 2, Pin 2 (Black). See Fig 1.
Programming Full Dial Low Warning (WARN LO)
This gauge can be configured to show a full dial low warning (flashing amber
backlight) when the gauge goes BELOW a specific value (i.e. AFR goes below
10).
1. To access WARN LO programming mode, press and hold the
MENU button until the pointer moves to 25% scale (approx 1
second). Release the MENU button after the pointer has reached
25% scale.
2. After releasing the MENU button the pointer will move to the current
low warning set point. Factory default is 0% scale (WARN LO
deactivated).
3. To change the set point, press the MENU button repeatedly to move
the pointer by 2% increments. Once the pointer reaches 100%
scale, pressing the MENU button will decrease the pointer position
by 2% increments.
4. Once the pointer indicates your desired low warning set point leave
the MENU button untouched for 5 seconds. The low warning set
point will be saved and the gauge will return to normal operating
mode.
To turn the low warning OFF, repeat steps 1-4 above and change the low
warning set point to 0% or 2% scale. Setting the low warning set point to 0%
or 2% deactivates the low warning feature.
Viewing and Clearing Peak Value (RECALL)
1. To view the peak value, press the MENU button one time.
2. To exit RECALL mode press the MENU button one time.
3. To clear the stored peak value press and hold the MENU button for
3 seconds while in RECALL mode.
External Warning Output (Optional)
When warning mode is active the gauge outputs a 12V+ DC signal (500mA)
on Pin 1 of Connector #1 (See Fig 1). This output is 0V when warning mode
is not active. This output can be used to activate an external warning light or
activate a switch.
Do not install Connector 1 if external warning output is not required.
Signal Input
The gauge is setup to work with the Innovate Motorsports’ factory wideband
output of 0v = 7.35 A/F and 5v = 22.39 A/F.
Lens Protective Film
The gauge comes with a soft protective plastic film on the lens. Carefully
remove the protective film when gauge installation is complete.
Lens Cleaning
The gauge lens is made of acrylic plastic. Do not use any chemicals or
abrasives on the lens. To prevent scratching, caution must be used when
cleaning. To clean, wipe lightly with a damp soft cloth.
Programming Full Dial High Warning (WARN HI)
This gauge can be configured to show a full dial high warning (flashing amber
backlight) when the gauge goes ABOVE a specific value (i.e. AFR goes above
17).
1. To access WARN HI pro gramming mode, press and hold the remote
button until the pointer moves to 75% scale (approx 3 seconds).
Note: the pointer will stop at 25% scale for approx 1 second (for
WARN LO programming mode), continue holding the button until the
pointer has reached 75% scale. Release the button after pointer
has reached 75% scale.
2. After releasing the button the pointer will move to the current high
warning set point. Factory default is 100% scale (WARN HI
deactivated).
3. To change the set point, press the MENU button repeatedly to move
the pointer by 2% increments. Once the pointer reaches 0% scale,
pressing the MENU button will increase the pointer position by 2%
increments.
4. Once the pointer indicates your desired high warning set point leave
the MENU button untouched for 5 seconds. The high warning set
point will be saved and the gauge will return to normal operating
mode.
To turn the high warning OFF, repeat steps 1-4 above and change the high
warning set point to 98% or 100% scale. Setting the high warning set point to
98% or 100% deactivates the high warning feature.
Full Dial Warning (ON/OFF)
If desired, the full dial warning can be turned OFF so that only the External
Warning Output activates when a high or low warning condition exists. To
turn Full Dial Warning OFF (or ON):
1. Press and hold t he MENU button until the pointer moves to 100%
scale (approx 4 seconds). Note: the pointer will stop at 25% scale
for approx 1 second, then 75% for approx. 1 second. Do not release
the MENU button until the pointer has reached 100% scale.
Release the button after the pointer reaches 100% scale.
2. After releasing the button the gauge backlighting will indicate
whether Full Dial Warning is currently ON or OFF. Gauge
backlighting will flash to indicate Full Dial Warning Mode is ON.
Gauge will remain unlit to indicate Full Dial Warning Mode is OFF.
3. Press the remote button to switch between Full Dial Warning ON
(flashing backlight) and OFF (no backlighting).
4. To save your changes, leave the MENU button untouched for 5
seconds. Full Dial Warning Mode (ON or OFF) will be saved and
the gauge will return to normal operating mode.
Doc# 11-0127 (Rev. C)