Ingersoll-Rand ARO 662608, ARO 662609, ARO 662605, ARO 662606 User Manual

OPERATOR’S MANUAL 66260X
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
INCLUDE MANUAL: 6564X-X AIR MOTOR (97999-174), AIRLINE SAFETY INFORMATION (100400-76) & S-633 GENERAL INFORMATION (PN 97999-624).
6” AIR MOTOR 100:1 RATIO 0 - 10,000 PSI. RANGE
662605, 662606, 662608 & 662609
PUMP ASSEMBLY
READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
RELEASED: 8-26-09 REVISED: 3-17-10 (REV. G)
SERVICE KITS
Use only genuine ARO® replacement parts to assure com-
y
patible pressure rating and longest service life. 65130 packing kit.
y
61355 for air motor service only.
y
SPECIFICATIONS
Model Series . . . . . . . . . 662605, 662606, 662608 & 662609.
Type . . . . . . . . . . . . . . . . . Air Operated Grease Pump
Ratio . . . . . . . . . . . . . . . 100:1
Air Motor Diameter. . . . . . . . . . . . . . 6” (15.2 cm)
Stroke. . . . . . . . . . . . . . . . . . . . . . 4” (10.2 cm)
Air lnlet (female) . . . . . . . . . . . . . 1/2-14 N.P.T.F.
Material Outlet (female). . . . . . . 1/2 - 14 N.P.T.F.
Dimensional Data . . . . . . . . . . . . . . . . see chart
PERFORMANCE
Air Inlet Pressure Range . . . . .
0 - 100 p.s.i.g (0 - 6.9 bar)
Fluid Pressure Range . . . . . . . 0 - 10,000 p.s.i.g (0 - 690 bar)
Maximum Delivery/ Min . . . . 2.1 lbs (0.95 kg)
OPERATING AND SAFETY PRECAUTIONS
WARNING
UAL INCLUDED FOR ADDITIONAL OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT IN­FORMATION.
WARNING
explosion resulting in severe injury or death. Do not exceed maximum operating pressure of 10,000 p.s.i.g (690 bar) at 100 p.s.i.g (6.9 bar) inlet air pressure. Do not run pump without using a regulator to limit air supply pressure to the pump.
WARNING
equipment failure resulting in severe injury or prop­erty damage. Do not exceed the maximum material pressure of any component in the system.
INLET PRESSURE TO PUMP MOTOR FLUID PRESSURE
Pump ratio is an expression of the relationship between the pump motor area and the lower pump end area. EXAMPLE: When 100 p.s.i.g (6.9 bar) inlet pressure is supplied to the motor of a 100:1 ratio pump it will develop a maximum of 10,000 p.s.i.g (690 bar)  uid pressure (at no  ow) - as the  uid control is opened, the  ow rate will increase as the motor cycle rate increases to keep up with the demand.
terial lines is exposed to elevated temperatures. Example: Material lines located in a non-insulated roof area can warm due to sunlight. Install a pressure relief valve in the pumping system.
READ THE GENERAL INFORMATION MAN-
EXCESSIVE INLET PRESSURE. Can cause
EXCESSIVE MATERIAL PRESSURE. Can cause
NOTICE
PUMP RATIO X
Thermal expansion can occur when the  uid in the ma-
MAXIMUM PUMP
=
662605 662606 662608 662609
“A”
“B”
Figure 1
NOTE: Dimensions are shown in inches and (mm), supplied for reference only and are typically rounded up to the nearest 1/16 inch.
MODELS
662605, 662606 662608, 662609
“A” (mm)
39-5/8” (1006) 49-7/16” (1256)
IMPORTANT
This is one of four documents which support the pump.
Replacement copies of these forms are available upon request.
66260X MODEL OPERATOR’S MANUAL 6564X-X AIR MOTOR OPERATOR’S MANUAL 100400-76 AIRLINE SAFETY INFORMATION MANUAL
S-633
GENERAL INFORMATION LUBRICATION PISTON PUMPS
“B” (mm)
25-7/16” (646) 35-1/4” (895)
Drum Size
120 lb.
400 lb. (55 gal.)
INGERSOLL RAND COMPANY LTD
P.O. BOX 151 y ONE ARO CENTER y BRYAN, OHIO 43506-0151
(800) 276-4658 y FAX (800) 266-7016
PARTS LIST / LOWER PUMP END
Item Description
1 Tube
2 Rod
3 Adapter (1) 92621 4 Pin (1) 92624 5 BaIl Guide (1) 92623 6 BalI (1) Y16-211 7 Piston and CyIinder (1) 66714 8 Gasket (1) 92628
9 Tube (1) 92627 10 Primer Rod (1) 90131 11 Washer (1) 90136 12 Foot Valve Sleeve (1) 4170 13 Snap Ring (1) Y147-77 14 Cup (1) 90757 15 Body (1) 90756 16 Washer (1) F21-56 17 Foot Valve Seat (1) 93269-1 18 Washer (1) 90133 19 Washer (1) 92630 20 Elastic Stop Nut (1) 95977302 21 Primer Tube (1) 92626
(size in inches)
(662605 & 662606)
(662608 & 662609)
(662605 & 662606)
(662608 & 662609)
Qty Part No.
(1) 92625-1 (1) 92625-2 (1) 92629-1 (1) 92629-2
INSTALLATION
Remove pump from packaging material and install and secure pump to cover, bung or other mounting accessory as ordered. See  gure 2 for view of complete assembly.
1.
Before connecting pump, first blow out material line with air.
.
2
After the system is hooked up, pump a small amount of material through the line. This material should be discarded. (Do this to clear any foreign material out of lines).
OPERATING INSTRUCTIONS
Be sure material hose, lines and other components are able to withstand pressure developed by pumps.
When a pump is installed and ready to operate: Connect air
1. supply to air motor inlet. Regulate air pressure from p.s.i.g (2.07 bar) to 50 p.s.i.g (3.4 bar). Allow pump to cycle slowly to prime with material and bleed all air from system
.
MAINTENANCE
If the pump is to be inoperative for a lengthly period of time (a few hours), disconnect air and relieve all pressure from system. Periodically flush pump with a solvent that is compatible with material being pumped. Disassembly should be done on a clean work bench with clean cloths to keep parts clean. If replacement parts are necessary, consult drawings contain­ing parts for identi cation. Before reassembling, lubricate parts where required. When assembling “0” rings or parts adjacent to “0” rings, care must be exercised to prevent damage to “0” rings and “0” ring groove surfaces.
Clean threads with solvent and apply Loctite 271 sealant to threads.
See View “A”
17
View “A”
13
14
15
TORQUE REQUIREMENTS
(1 & 9) 300 ft lbs (406.8 Nm) minimum.
Figure 2
1
2
3
4
5
6
7
8
9
10
11 12
16
18
19
20 21
Page 2 of 4 66260X