Husqvarna S13, S26, S36, S26, S13, S36 Operator's Manual

Operator s manual
US
S-Line Dust Extractor
13, S26, S36
S
Please read the operator’s manual carefully and make sure you understand the instructions before using
the machine.
1. SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
WARNING – To reduce the risk of fire, electric shock or injury:
Cables damaged through crushing or splitting can be dangerous if used and should be replaced
immediately. Risk of personal injury.
Make sure the assembly area is firm, so the dust extractor does not tip over. Risk of personal and
material injury.
Risk of pinching when handling the toggle fasteners.
The machine must not be used in environments where explosive gases may be present. Serious risk of
explosion.
Improper connection of the equipment-grounding conductor can result in a risk of electrical shock.
Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the machine. If it will not fit the outlet. Have a proper outlet installed by a qualified electrician.
Before using the machine, make sure that the power & voltage corresponds with the voltage shown on
the machines rating plate.
Do not leave machine when plugged in. Unplug cord from outlet when not in use and before cleaning or
servicing machine.
Do not use outdoors or on wet surface, this machine is for indoor and dry use only.
Do not allow to use as a toy. Close attention is necessary when used by or near children.
Use only as described in this manual. Use only manufacturers recommended attachments.
Operators shall be adequately instructed on the use of the machine
This machine is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge.
Do not use with damaged cord or plug. If the machine is not working as it should, has been dropped,
damaged, left outdoors or dropped in water. Make sure it is repaired by a qualified person.
Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp edges
or corners. Do not run the machine over cord. Keep cord away from heated surfaces.
Do not unplug by pulling on cord. To unplug, grasp the plug. Not the cord.
Make sure the cord is unplugged when performing service or maintenance to the product.
Do not handle plug or machine with wet hands.
Regularly inspect cord and plug for damage. If cord is damaged, it must be replaced by a qualified
person in order to avoid hazard.
Do not put any object into openings. Do not use with any opening blocked (accept during filter cleaning
procedure). Keep free of dust, hair and anything that may reduce airflow.
Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
Turn off all controls before unplugging.
Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they
may be present.
Do not pick up any type of liquids.
Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
Use extra care when cleaning on stairs.
Do not use without dust bag and/or filters in place. Replace collection system and/or filters as described
in manual.
If using an extension cord make sure the cord rating is suitable for this machine.
Do not modify machine from its original design.
Keep children and unauthorized persons away from machine when in use.
All repairs must be performed by a qualified service person. Use only manufacturer-supplied or
equivalent replacement parts.
Do not expose machine to rain or moisture. Store indoors only.
Connect to a properly grounded outlet only. See grounding instructions.
Make sure that you read and understand the instructions for the main product to ensure that you know
what personal equipment to wear, what safety equipment to use and how to work in a safe mode.
THERMAL PROTECTION
The dust extractor is equipped with a safety thermal protector to prevent motor from overheating.
Should thermal protector activate, turn off machine, unplug power cord and check for full dust bag, vacuum hose clog or filter blockage. It may take up to 45 minutes for the thermal protector to reset.
GROUNDING INSTRUCTION
The dust extractor must be grounded. If it should malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the risk of electric shock. The dust extractor is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
SAFETY LABEL
The following label appears on the machine, next to the
machines rating plate. Replace label if it is missing, becomes damaged or illegible. Failure to follow this warning label may result in fire, electric shock or injury.
1.1. Type plate
CHINA
CHINA
CHINA
2. UNPACKING
When unpacking the machine, please check that the following accessories are included:
The hose with end fittings.
Wand.
Floor nozzle.
If any of the above-mentioned parts are missing, please contact your local distributor or our sales representative. For models that do not already have the front casters assembled due to packaging limitations. Assemble the front casters using the using bolt or nut and washer that are included in the package depending on your application. Protect the envir Plea
se dispose of packaging materials and used machine components in an environmentally safe way according
to local disposal regulations. Always remember to recycle.
onment:
2.1 Product overview S13 S26
!
"
#
$
!
"
#
$
1 Hose 2 Suction Pipe 3 Floor tool 4 Rubber blades
S36
3. FUNCTION
The machine is designed for vacuuming and separating dry, non-combustible dust with an explosion limit value of >0.1mg/m
3
.
The dust extractor is started by the switch.
Type
Models without automatic start
Autostart function models
Red switch 2 step
0: Motor off, 1: Motor on
N/A
Black switch 3 step
N/A
0: Motor off, 1: Motor on, 2: Automatic start
Dust-laden air is then sucked through the inlet valve at high speed via the suction hose. The air is slowed down by the cyclone and coarse dust particles are separated out, partly by centrifugal force and partly by gravity. Air and finer particles then pass through the double filter system where separation is made. The machine is designed for filter cleaning by reverse air pulse. The separated dust accumulates in the cyclone until the machine is switched off, when it drops through the bottom flap into the plastic bag. The filter cleaning process is not completed before it is clear that the dust inside the tank has fallen down into the collection bag. In some extreme cases the adhesive ability of the dust must be broken manually. This can be done by hitting the dust through the bag or tapping the tank using i.e. a rubber hammer.
Automatic start function:
When you use the dust extractor together with another machine, there is an electrical outlet on the dust extractor. Connect the machine to this outlet. Then when you start it up the dust extractor will also start after 5orms55. 1-2 seconds. When you turn it off, the dust extractor will continue to run for approximately 10 seconds. To empty the hose. Then stop
4. FILTER CLEANING
The filter must be cleaned from time to time. This must be done before changing the bag collection system and should also be done when work is completed or when there is poor suction. Procedure: Cover the inlet, if applicable, use attached cover. First let the machine build up vacuum for four to five seconds then quickly push down on the key and release it. Repeat the procedure five times. It is important to let the machine rebuild the vacuum in between every repetition.
Turn off the motor and wait until it stops completely, then uncover the inlet.
If suction remains poor, the pre-filter needs to be replaced. If suction still remains poor afterwards, the Hepa filters needs to be replaced. See instructions in chapter 6. FILTER CHANGE.
5. DUST STORAGE SYSTEM
The dust extractors are mainly equipped with Longopac system for effective dust storage or a regular plastic bag system depending on model. Longopac is a 22 m long plastic tube that will be divided into plastic bags using the zip ties attached with the machine.
To assemble a new Longopac bag: Release the belt holding the last bag. Remove the holder, put in a new Longopac bag & pull out the inner end upwards. Assemble the holder on to the machine and strap the opening facing upwards with the belt. Pull down the outside end and close it using a zip tie. All dust extractors can be used with original Husqvarna dust bags for single use. Also all models can be fitted with the longopac system. Only change Longopac or regular bag after filter cleaning cycle have been completed.
6. FILTER CHANGE
Risk of dust dispersion – Use personal safety equipment Unhealthy dust can be spread during filter change. Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask conforming to protection class FFP3.
Wear breathing mask Wear ear protection Wear protective glasses
Pre-filter
Loosen the 3 clamps and remove the top. Take the bag from the new filter. Lift out the filter and place it gently in a plastic bag. This bag must be properly disposed. Insert a new filter.
Important:
If you are removing the Pre-filter in order to clean it. Hitting the filter with force or use of compressed air will destroy the filter. It can handle water, but high pressure water cleaning will destroy it.
Hepa Filter
Loosen the two nuts on each filter cover cap. Carefully lift the filter into a clean plastic bag, use the bag from the new filter. This bag must be properly disposed. Insert a new filter in reverse order.
Important:
Hepa filters can’t be cleaned, trying this might destroy it. When installing the replacement filter, make sure to not touch the inside of the filter. Any kind of force/damage on the inside of filter media will destroy the new filter.
Recommended intervals for filter change: Socks filter every 6 months and Hepa filter every 12 month.
7. SERVICE
When cleaning and servicing the machine, you must switch off the machine and remove the plug from
the outlet.
Avoid cleaning with a high pressure cleaner. If necessary, do not direct at the openings on the machine,
especially the opening for cooling air.
Before moving the machine from the work area, the machine must be cleaned.
All other equipment must be regarded as contaminated and be treated thereafter.
If possible, use a special suitable room.
Proper personnel protective equipment must be used. Dust can be spread when the coarse filter and the
absolute filter are replaced that can be hazardous to health. Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask conforming to protection class FFP3.
All parts which are contaminated after service must be properly disposed of in plastic bags according to
all regulations.
If the machine has to be used for other purposes, it is extremely important that the machine is cleaned,
to avoid the spread of hazardous dust.
Do not puncture the Hepa filter. Risk of dust dispersion.
WARNING
Remember to switch off the machine and pull the plug out of the outlet before servicing.
Replacement parts, Filters and Dust collection system
Part no:
Description
S13
S26
S36
590426101
Longopac (4-bags)
1 1 1
590396101
Plastic bags (25-pcs)
1 1 1
590397401
Pre-filter S13
1
N/A
N/A
590426501
Pre-filter S26
N/A
1
N/A
590448501
Pre-filter S36
N/A
N/A
1
590396601
HEPA FILTER S-LINE
1 2 3
590402901
HEPA FILTER S-LINE USA
1 2 3
8. WARRANTY
All Husqvarna devices and accessories have a 12-month factory warranty for material and manufacturing defects. The warranty extends to 36 months when returning the attached warranty slip. Do not attempt to repair the suction apparatus without the consent of the manufacturer. The warranty does not cover defects which are the result of normal wear and tear, negligence, defective use, unauthorised repair or the suction apparatus being connected to the incorrect voltage. In the event of any complaint, the suction apparatus or an agreed part of it must be returned to us or our authorised representative for warranty examination and for any warranty repair or replacement.
9. PROBLEM SOLVING
The dust extractors are designed and manufactured for severe environments and tasks, but the user must note that the machine must be protected from knocks and blows. Filter, seals, attachments, and connections are carefully adapted and selected with regard to the operator’s work environment. Therefore, the operator and service personnel must treat the machine with care in order for it to work correctly for many years.
Issue
Cause
Solution
Motor doesn’t start
No power
Plug in machine
Cable defective
Replace cable
Switch defective
Replace switch
Soft start defective
Replace soft start
Motor stops immediately after starting Wrong fuse
Connect to correct fuse
Shortcut in cable/machine
Order service
Motor runs but there is not suction
Hose not connected
Connect hose
Hose clogged/blocked
Clean hose
No dust collection bag
Fit dust collection system
Motor runs but poor suction
Hole in hose
Replace hose
Filter clogged
Clean filter/Replace filter
Loose top cover
Adjust
Defective gaskets
Replace affected gaskets
Dust blown from motor
Wrongly assembled or damaged filter system
Adjust/Replace filters Abnormal noise
Order service
SAVE THESE INSTRUCTIONS!
10. TECHNICAL DATA
Data
Unit
S13 120 V
S26 120 V
S26 230 V
S36 120 V
S36 230 V
Voltage
(single phase)
V
120
120
230
120
230
Power (max)
kW
1,2
2,4
2,4
3,2
3,6
HP
1,6
3,2
3,2
3,2
4,8
Current (max)
A
10,0
20,0
10,0
20,0
15,7
airflow (max)
m3/h
219
438
438
485
600
cfm
129
258
258
285
353
Vacuum (max)
kPa
24
24
24
18
28
Water lift
ln
100
100
100
80
110
Main hose
Metric
(mm)
4m x 38
7,5m x 51
7,5m x 51
10m x 63
10m x 63
USCS
13’ x 1,5”
24’ x 2”
24’ x 2”
32’ x 2,5”
32’ x 2,5”
Inlet
Metric
(mm)
51
63
63
63
63
USCS
2”
2,5”
2,5”
2,5”
2,5”
Pre-filter
EN779-F8
%
@1um
>99,5
>99,5
>99,5
>99,5
>99,5
Pre-filter area
Metric
1,5 m²
3 m²
3 m²
4,5 m²
4,5 m²
USCS
16 ft²
32 ft²
32 ft²
48 ft²
48 ft²
Hepa filter
EN1822-H13
99,99%
@0.3um
1 2 2 3 3
Total HEPA filter
area
Metric
1,2 m²
2,4 m²
2,4 m²
3,6 m²
3,6 m²
USCS
13 ft²
26 ft²
26 ft²
39 ft²
39 ft²
Sound level
dB(a)
70
70
70
70
70
Dust collection
system
Type
Plastic bag
Longopac
Longopac
Longopac
Longopac
Dimensions
(L*W*H)
Metric
(mm)
680x400x1100
756x546x1275
756x546x1275
840x620x1500
840x620x1500 USCS
26x15,8x43,3 ”
29x21,5x50,2 ”
29x21,5x50,2 ”
33x24,5x60 ”
33x24,5x60 ”
Weight
Metric
29 kg
47 kg
47 kg
63 kg
63 kg
USCS
66 lbs
105 lbs
105 lbs
140 lbs
140 lbs
11. PLUGS
MODEL
PLUG TYPE
RECEPTACLE
TYPE
RECEPTACLE
MAX AMPS
CABLE &
PLUG
MAX
AMPS
S13 120 V
NEMA 5-15P
N/A
N/A
15 A
S13 230 V
SOCKET F GROUNDED
SOCKET F
5 A
10 A
S26 120 V
NEMA 5-20P
N/A
N/A
20 A
S26 230 V US
NEMA L6-15P
N/A
N/A
15 A
S26 230 V
SOCKET F GROUNDED
N/A
N/A
10 A
S36 120 V US
NEMA 5-20P
N/A
N/A
20 A
S36 230 V 30A
NEMA L6-30P
NEMA L6-30
20 A
30 A
S36 230 V 50A
NEMA L6-50P
NEMA L6-50
35 A
50 A
S36 230 V
IEC 60309 16 A
N/A
N/A
16 A
The grounding methods of S13 120V machine follow the UL1017 section 11.3.1 part b) as below:
For a grounded, cord-connected appliance rated less than 15 A and intended for use on a nominal 120-V supply circuit, the instructions in either item 1 or 2:
1) This appliance is for use on a nominal 120-V circuit, and has a grounded plug that looks like the plug illustrated in sketch A in Figure 20. A temporary adaptor that looks like the adaptor illustrated in sketches B and C may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet (sketch A) can be installed by a qualified electrician. The green colored rigid ear, lug, or the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw.
Exception: In Canada, the use of a temporary adaptor is not permitted by the Canadian Electrical Code, C22.1.
2) This appliance is for use on a nominal 120-V circuit and has a grounding attachment plug that looks like the plug illustrated in sketch A in Figure 20. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance.
The grounding methods of S26 120V, S26 230V, S36 120V US, S36 230V 30A AND S36
230V 50A follow the UL1017 section 11.3.1 part c) as below:
For all other grounded, cord-connected appliances: This appliance is for use on a circuit having a nominal rating more than 120 V (or This appliance is rated more than 15 A and is for use on a circuit having a nominal rating of 120 V) and is factory-equipped with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance. If the appliance must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel.
Original instructions
www.husqvarnacp.com
1158771-26
2017-03-24
Loading...