Up to two Intel® Quad-Core 5500 sequence processors
3.
Two 3.5" non-hot plug hard drives using a quick release
drive carrier
Rear View:
1.
Serial Port
2.
Video Port
3.
(2) USB Ports
4.
(2) 1Gbit NIC
5.
Optional Dedicated Management port
6.
UID
7.
Optional low profile x16 PCI-e Gen 2
8.
Power Button
9.
Health LED
At A Glance
The HP ProLiant SL160z G6 server is part of a new family, HP ProLiant SL6000, of HP server solutions optimized for scaleout customers to greatly reduce costs, maximize power efficiency, by sharing power supplies and fans, and maintain total
flexibility.
Two independent HP ProLiant SL160z G6 Servers go into the 2U HP ProLiant z6000 G6 Chassis. The HP ProLiant SL160z
G6 Server is a two socket Intel server with 18 DDR3 DIMM sockets and support for a low profile x16 PCI-e Gen 2 and an
internal x4 PCI-e Gen 2 slot.
The HP ProLiant SL160z G6 is optimized for applications needing large amounts of memory and I/O expansion.
Processors
Memory
Internal Drive Support
Network Controller
Storage Controllers
Expansion Slots
:
Supports up to two Intel® Quad-Core 5500 sequence processors
Quad-Core Intel® Xeon® processors 5500 sequence with 4MB or 8 MB Level 3 cache (depends on model)
Intel® 5520 Chipset
:
Up to 144GB, using PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated
at 3 DIMMs per Channel in 18 slots.
Up to 24GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully
populated at 2 DIMMs per Channel in 12 slots.
:
Support for up to two 3.5" non-hot plug Serial ATA (SATA) hard drives using a quick release drive carrier
Internal storage capacity of up to 2.0TB (2 x 1TB 3.5" SATA)
:
HP NC362i Integrated Dual Port Gigabit Server Adapter
:
Non-Hot Plug SATA Models: HP Embedded SATA RAID Controller (RAID 0, 1, 10)
NOTE:
Transfer rate: up to 3 Gb/s SATA
:
Up to two available PCI Express 2.0 slots:
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 1
QuickSpecs
HP ProLiant SL160z Generation 6 (G6)
Overview
Standard Slot 1: low-profile x16 PCI-Express 2.0
Optional Slot 2: low-profile internal only x4 PCI-Express 2.0
Management
HP ProLiant Onboard Administrator Powered by Lights-Out 100 with optional LO100i Advanced Licenses for
Virtual KVM and Virtual Media
The HP ProLiant Easy Set-up CDs and ISO image downloads offer Assisted and Manual single server
installation, setup, and deployment capability. Capabilities provided are:
HP Insight Diagnostics
Smart Components - a self-executable software consisting of driver and firmware
HP Smart Update Manager - a single system and multi-server deployment tool for Windows environments that
works with Smart Components to provide customers with easy-to-use GUI and Script-based deployment
capacity
SmartStart Scripting Toolkit - an automated scalable deployment utility
Insight Management Agents for environmental monitoring that is similar to and consistent with that of HP
ProLiant 300 series servers and above servers and that allows integration to HP Systems Insight Manager
(SIM).
Array Configuration Utility (ACU)
Array Diagnostics Utility (ADU)
Operating Systems and Virtualization Software Support for ProLiant Servers
Supports Windows, RHEL, SLES, Solaris, VMware, and Citrix Essentials for XenServer
USB Ports
Three USB ports (two front, one internal)
NOTE:
internal USB header.
Optical Drive
External support only
Power Supply
The 2U chassis supports three power supply options:
Form Factor
HP ProLiant z6000 G6 Chassis - 2U
HP ProLiant SL160z Server - 1U server tray
Deployment/Serviceability
HP ProLiant SL160z G6 models have two different rail kits to choose from:
Customer Self Repair (CSR): HP products are designed with many CSR parts to minimize repair time and allow
for greater flexibility in performing defective parts replacement
Warranty
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of
HP Authorized Channel Partners. Hardware diagnostic support and repair is available for one year from date of
purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to
warranty services are available through HP Care Pack services or customized service agreements. SATA hard
drives have a one year warranty. SAS Midline drives have a one-year warranty. SAS Enterprise drives have a
three-year warranty.
NOTE:
accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1)
Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers
decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but
may involve added complexity. Customers may choose to have HP replace Optional CSR parts at no charge.
:
AutoRun
Assisted Installation Microsoft Windows 2003 Server and Microsoft Windows 2008 Server.
OS and SW available for Manual Installation are listed on each servers' QuickSpecs
:
In order to utilize the internal USB port the USB cable (P/N: 536769-B21) must be connected to the
:
:
Common Slot Power Supplies enable power capping and hot-pluggability
HP 1200W CS HE Silver Power Supply (Hot Plug, Autoswitching) (optional)
HP 750W CS HE Gold Power Supply (Hot Plug, Autoswitching) (optional)
HP 460W CS HE Gold Power Supply (Hot Plug, Autoswitching) (optional)
:
:
10U bulk rail kit - Used to fit in HP 10000 series racks
One 10U bulk rail kit will hold up to five z6000 chassis, thus ten SL160z G6 servers
2U rail kit - Used to fit in 3rd party racks or to sell one z6000 chassis at a time
One 2U rail kit will hold one z6000 chassis, thus two SL160z servers
:
Server Warranty includes 1 year Parts, 1 year labor, and 1 year on-site service. Warranty repairs may be
:
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 2
QuickSpecs
Overview
Additional information regarding worldwide limited warranty and technical support is available at:
Available through Configure To Order only. See Factory Integration Models section for
more details.
NOTE:
HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE:
Turbo indicates the maximum potential frequency increment when using Intel® Turbo
Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE:
DDR3 speed is the maximum memory speed of the processor. Actual memory speed may
depend on the quantity and type of DIMMs installed.
NOTE:
For the Intel 5500 Series, the letter preceding the model number indicates the
performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes
Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
HP ProLiant SL160z Generation 6 (G6)
Upgradeability
Chipset
Cache Memory
Memory Protection
Upgradeable to two processors
Intel® 5520 Chipset
8 MB (1 x 8MB) Level 3 cache
NOTE:
All processor models except for those identified below.
4 MB (1 x 4MB) Level 3 cache
NOTE:
For processors L5506, E5504, E5502.
Advanced memory protection
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 4
QuickSpecs
Standard Features
HP ProLiant SL160z Generation 6 (G6)
Memory
Type
Standard (per server tray)
Maximum (RDIMM) (per
server tray)
Maximum (UDIMM) (per
server tray)
NOTE:
Depending on the memory configuration and processor model, the memory speed may run
at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at:
www.hp.com/go/ddr3memory-configurator
NOTE:
Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy
Efficient Features, see:
DDR3 Registered (RDIMM) or Unbuffered (UDIMM)
6 GB (3 x 2 GB) UDIMMs
144 GB (18 x 8 GB) for Registered Memory configurations
24 GB (12 x 2 GB) for Unbuffered Memory configurations
.
www.hp.com/go/proliant-energy-efficient
.
Network Controller
Expansion Slots
Storage Controller
HP NC362i Integrated Dual Port Gigabit Server Adapter
Slot #
1
NOTE:
* Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment
number.
** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest
Device ID by bus (starting with the lowest bus).
Non-Hot Plug SATA
Models:
NOTE:
NOTE:
NOTE:
Pack is needed to install storage controller drivers during a Windows operating system installation
from a CD.
Technology
PCI-
Express 2.0
All slots can accept universal keyed PCI cards.
Transfer rate: 3.0 Gb/s SATA
A HP Smart Array Controller is required for SAS HDD
An external diskette drive, USB floppy drive key or virtual FDD using LO100 Advanced
Bus Width
x16x16
HP Embedded SATA RAID Controller (RAID 0, 1, 10)
Connector
Width
*
Bus
Number
10
*
Device
No.
**
Form
Factor
Low Profile
Notes
3.3 volts
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 5
QuickSpecs
Standard Features
HP ProLiant SL160z Generation 6 (G6)
Storage
Maximum Internal
Storage
Interfaces
Optical Drives
Diskette Drives
Drive Bays
Non-Hot Plug SATA
Parallel
Network RJ-45
Serial
Pointing Device (Mouse)
Graphics
Keyboard
USB
Management
Health LED
Power
UID
DVD-ROM / DVD RW drives via USB only
Via USB only
None ship standard
Up to 2 Non-hot plug SATA 3.5" drives
2.0TB
None
2 10/100/1000 NIC ports (plus 1 optional dedicated port for the HP
ProLiant Lights Out 100i Remote Management)
1
0 (via USB only)
1
0 (via USB only)
3 (two front, one internal)
NOTE:
In order to connect a USB device internally, the internal USB
Cable G6 Kit must be used (536769-B21)
NOTE:
Please see the following URL for additional information
regarding USB support:
Can support two SL160z server trays in the 2U chassis.
HP ProLiant SL160z G6 Server - 1U server tray
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 6
QuickSpecs
Standard Features
HP ProLiant SL160z Generation 6 (G6)
Embedded Systems
Management
Server Management
Stand Alone Software
Products
HP ProLiant Onboard
Administrator Powered
by LO100 with LO100i
Advanced Licenses
HP Insight Rapid
Deployment software
HP Systems Insight
Manager
HP ProLiant Onboard Administrator Powered by Lights-Out 100 is
standard with this server and has LO100i Advanced Licenses for Virtual
KVM and Virtual Media available as options.
Features:
Embedded IPMI reporting
System event log access
Remote Serial console (serial redirection)
Browser, Telnet access
SMASH-CLP compliant
IPMI 2.0 compliant
DCMI 1.0 compliant
Secure Socket Layer Encryption
Secure Shell Encryption
Virtual media (Floppy, CD, USB 2.0) with Advanced Licenses
Virtual KVM with Advanced License
HP Insight Rapid Deployment software (RDP) extends HP Systems
Insight Manager with a complete deployment solution for HP ProLiant
servers. RDP provides a central location to configure server hardware,
deploy Windows, Linux and VMware ESX operating environments and
install HP ProLiant Support Pack drivers using images and scripted
profiles. For more information, visit:
HP Systems Insight Manager (HP SIM) provides a unified, secure and
extensible standards-based environment to centrally manage servers,
storage and other infrastructure devices, (both HP and non-HP) across
multiple operating system platforms.
For additional information, please see:
http://www.hp.com/go/rdp
http://www.hp.com/go/insight
.
.
Core Infrastructure
Management
Easy Set-up CD and
ISO Image Web
downloads
Subscriber's Choice
ROMPaq, software and
latest drivers
Subscriber's Choice Driver and Support Alerts/Notifications is a webbased email subscription service that provides software and driver
change notifications for ProLiant products. Sign up at:
http://www.hp.com/go/subscriberschoice
receive various new alerts as they become available, on a weekly or
monthly basis.
The latest software, drivers, and firmware fully optimized and tested for
your ProLiant server and options; downloaded from Software and
Drivers download pages website at:
from
www.hp.com/servers/easysetup
HP Insight Management Agents for Systems Insight Manager
(SIM) Integration
HP Systems Management Homepage
Array Configuration Utility (ACU)
Array Diagnostics Utility (ADU)
HP Insight Diagnostics
and customize your profile to
http://www.hp.com/go/support
. Contains the following:
and
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 7
QuickSpecs
Standard Features
HP ProLiant SL160z Generation 6 (G6)
Industry Standard
Compliance
Security
Security - Trusted
Platform Module
ACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0
DCMI 1.0
SMASH CLP compliant
Power-on password
Setup password
Diskette boot control
Secure Sockets Layer (SSL)
Secure Shell (SSH)
The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used
to authenticate the server platform. These artifacts can include passwords, certificates and
encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature
available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a
Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user
data and to ensure that a server running Windows Server 2008 has not been tampered with while
the system was offline.
Server Power Cords
UPS and PDU Power
Cord Matrix
NOTE:
For more information about TPM, including a white paper, go to:
http://www.hp.com/go/TPM
NOTE:
ProLiant OS pre-installed units will come with the partition required for TPM deployment.
NOTE:
The TPM key is unique to every TPM deployed server and must be retained. Misplacing or
losing the key could result in data loss.
One 6' Highline (IEC-IEC) power cord ships standard
NOTE:
HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002)
that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are
primarily connected to PDU's in data center racks so they now ship standard with only a PDU
power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle
(NEMA-15), the NEMA power cord (227099-001) must be ordered separately.
If customers require a local power cord, they can check the power cord matrix for the appropriate
cord. Please see the following power cord matrix:
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page.
Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions,
requirements, and specifications for UPS and PDU units. Please see the following link:
www.hp.com/products/powercords
.
http://www.hp.com/go/powercordmatrix
.
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 8
QuickSpecs
Standard Features
HP ProLiant SL160z Generation 6 (G6)
Power Supply
Common Slot ProLiant
HP has a new design for ProLiant power- the new Common Slot Power Supply bay. This design
provides the customer with commonality in power supplies across multiple platforms to save on
the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs.
Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power
Supplies. The new HP Common Slot power supplies are designed for the highest power efficiency
without degrading performance of the ProLiant server. Power Supplies have efficiency ratings up
to 92%. There are three Right Size power options available depending on the configuration of your
server. To make sure you select the correct power supply to meet your configuration, please use
the HP Power Advisor at:
www.hp.com/go/hppoweradvisor
Compliant, Hot Plug and Redundant.
It is highly recommended that you use the HP Power Calculator in defining the "Right-Size" power
supply for your needs. HP offers three Power Supply Options:
460Watts, Common Slot,92% Efficiency
750Watts, Common Slot, 92% Efficiency
1200Watts, Common Slot, 90% Efficiency
The HP ProLiant Common Slot Power supplies meet multiple Energy Efficiency Initiatives: Climate
Savers Computing Initiative GOLD and ECOS Consulting 80PLUS GOLD for the 460w and 750w
Power Supplies and Climate Savers Computing Initiative Silver, ECOS Consulting 80PLUS Silver
for 1200w Power Supply. HP has also been working with the EPA on developing an ENERGY
STAR? Computer Server specification and plans on offering models that meet the requirements
when they are published. Please visit the ENERGY STAR website at:
updates on the specification development process and approved platforms.
www.hp.com/go/proliant-energy-efficient
. All HP Common Slot power sources are UL, CE Mark
or
www.energystar.gov
for
System Fans
Operating Systems and
Virtualization Software
Support for ProLiant
Servers
Optional power supplies can be purchased through power supply option kits (see Power Supply
Options for part numbers).
3 system fans ship standard in z6000 chassis
Microsoft Windows Server
Microsoft Windows Server Hyper-V
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
VMWare
Citrix Essebtials for XenServer
NOTE:
For more information on HP's Certified and Supported ProLiant Servers for OS and
Virtualization Software and latest listing of software drivers available for your server, please visit
our Support Matrix at:
http://www.hp.com/support/SL160G6
http://www.hp.com/go/ossupport
.
and our driver download page
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 9
QuickSpecs
Standard Features
HP ProLiant SL160z Generation 6 (G6)
Rack Airflow
Requirements
Rack Support
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for
maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow
5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom to permit adequate
airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must
be a minimum of 7 cm (2.75 inches)
CAUTION:
This arrangement ensures proper airflow. Using a rack without blanking panels results in improper
cooling that can lead to thermal damage.
NOTE:
CD provided with the server, or to the server documentation located in the Support section at the
following URL:
HP ProLiant SL160z G6 models have two different rail kits to choose from:
If a third-party rack is used, observe the following additional requirements to ensure
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack.
For additional information, refer to the Setup and Installation Guide or the Documentation
www.hp.com/servers/SL160
.
Factory Express
Portfolio for Servers
and Storage
HP Enterprise
Configurator
10U bulk rail kit - Used to fit in HP 10000 series racks
One 10U bulk rail kit will hold up to five z6000 chassis, thus ten SL160z G6 servers
2U rail kit - Used to fit in 3rd party racks or to sell one z6000 chassis at a time
One 2U rail kit will hold one z6000 chassis, thus two SL160z servers
For additional information, please visit:
HP Factory Express offers configuration, customization, integration and deployment services for
HP servers and storage products. Customers can choose how their factory solutions are built,
tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading,
asset tagging, and custom packaging. HP products supported through Factory Express include a
wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP
BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries
and configurable network switches.
For more information on Factory Express services for your specific server model please contact
your sales representative or go to:
The HP eConfigure Enterprise Configurator now provides factory default racking for our HP
hardware portfolio. This approach is aligned with our strategic direction to meet the needs and
expectations of our valued customers. If you require "custom" rack configuration, please contact
HP's Customer Business Center or an Authorized Partner for assistance.
http://www.hp.com/products/configurator
www.racksolutions.com
http://www.hp.com/go/factory-express
.
.
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 10
Loading...
+ 23 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.