HP PROLIANT DL360 G3 User Manual

HP ProLiant DL360 Generation 3
Server
Setup and Installation Guide
Part Number 293974-001
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the U.S. and other countries.
Intel and Pentium are trademarks of Intel Corporation in the U.S. and other countries.
UNIX is a trademark of The Open Group in the U.S. and other countries.
Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided “as is” without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
September 2002 (First Edition) Part Number 293974-001

Contents

About This Guide
Intended Audience............................................................................................................. ix
Important Safety Information ............................................................................................ ix
Symbols on Equipment ..................................................................................................... ix
Rack Stability .................................................................................................................... xi
Symbols in Text.................................................................................................................xi
Related Documents........................................................................................................... xii
Getting Help ..................................................................................................................... xii
HP Technical Support................................................................................................ xii
HP Website ............................................................................................................... xiii
HP Authorized Reseller ............................................................................................ xiii
Reader’s Comments ........................................................................................................ xiii
Chapter 1
Planning the Server Installation
HP ProLiant DL360 Generation 3 Server Features ......................................................... 1-1
Server Installation Overview........................................................................................... 1-1
Optimum Environment.................................................................................................... 1-3
Space and Airflow Requirements ............................................................................. 1-3
Temperature Requirements....................................................................................... 1-4
Power Requirements ................................................................................................. 1-4
Grounding Requirements .......................................................................................... 1-5
Rack Planning Resources ................................................................................................ 1-5
Rack Warnings and Cautions .......................................................................................... 1-6
Server Warnings and Cautions ........................................................................................ 1-6
Server Shipping Contents................................................................................................ 1-7
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide iii
Contents
Chapter 2
Installing Hardware Options
Accessing Internal Server Components ...........................................................................2-2
Accessing Internal Components when the Server is out of the Rack........................2-2
Accessing Internal Components when the Server is in the Rack ..............................2-2
Identifying System Board Components ...........................................................................2-6
Installing Additional Memory..........................................................................................2-7
Replacing an Expansion Board........................................................................................2-9
Removing an Expansion Board.................................................................................2-9
Inserting an Expansion Board into the PCI Riser Board Assembly ........................2-11
Installing or Replacing an Optical Device .....................................................................2-13
Installing Hot-Plug Hard Drives ....................................................................................2-15
Installing a Second Processor and Processor Power Module (PPM).............................2-16
Installing a Hot-Plug Redundant Power Supply ............................................................ 2-19
Hot-Plug Power Supply Setup.................................................................................2-19
Converting Hot-Plug Power Supply Bay 2 .............................................................2-20
Installing a Hot-Plug Redundant Power Supply......................................................2-22
Hot-Plug DC Power Supply Wiring Setup..............................................................2-23
Installing the Battery-Backed Write Cache Enabler ......................................................2-25
Chapter 3
Server Installation
Server Installation Procedures .........................................................................................3-1
Measuring with the Template....................................................................................3-1
Installing the Universal Rack Rails ...........................................................................3-3
Installing the Server into the Rack ............................................................................3-5
Attaching the Cable Tray ..........................................................................................3-7
Connecting the Peripheral Device Cables and Power Cord............................................ 3-8
Securing the Cables in the Cable Tray........................................................................... 3-10
Powering Up the Server.................................................................................................3-12
Installation Sequence ..................................................................................................... 3-13
Operating System Purchased Separately.................................................................3-13
Preconfigured Operating System.............................................................................3-14
Registering the Server.................................................................................................... 3-15
Routine Maintenance ..................................................................................................... 3-15
Optional Installation Service..........................................................................................3-15
iv HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
Chapter 4
Server Configuration and Utilities
ROM-Based Setup Utility ............................................................................................... 4-1
Redundant ROM Support................................................................................................ 4-1
Safety and Security Benefits..................................................................................... 4-2
Access to Redundant ROM Settings......................................................................... 4-2
Disaster Recovery ..................................................................................................... 4-2
ROMPaq..........................................................................................................................4-3
SmartStart Software ........................................................................................................ 4-4
SmartStart Autorun Menu ............................................................................................... 4-5
SmartStart Scripting Toolkit............................................................................................ 4-5
Insight Manager............................................................................................................... 4-6
Survey Utility ..................................................................................................................4-6
Enterprise Diagnostics LX32 Utility ............................................................................... 4-7
Option ROM Configuration for Smart Arrays ................................................................ 4-7
Automatic Server Recovery ............................................................................................ 4-8
Power-On Self-Test......................................................................................................... 4-8
System Firmware Update ................................................................................................ 4-8
Auto-Configuration Process ............................................................................................ 4-9
Boot Options....................................................................................................................4-9
System Maintenance Menu ............................................................................................. 4-9
Integrated Management Log.......................................................................................... 4-10
Embedded NIC Configuration....................................................................................... 4-10
Integrated Lights-Out Setup .......................................................................................... 4-10
Contents
Appendix A
Regulatory Compliance Notices
Regulatory Compliance Identification Numbers............................................................ A-1
Federal Communications Commission Notice............................................................... A-1
Class A Equipment .................................................................................................. A-2
Class B Equipment................................................................................................... A-2
Declaration of Conformity for Products Marked with the FCC Logo –
United States Only ................................................................................................... A-3
Modifications ........................................................................................................... A-3
Cables....................................................................................................................... A-3
Canadian Notice (Avis Canadien) .................................................................................. A-4
Class A Equipment .................................................................................................. A-4
Class B Equipment................................................................................................... A-4
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide v
Contents
European Union Notice ..................................................................................................A-4
Japanese Notice............................................................................................................... A-5
Taiwanese Notice............................................................................................................ A-5
Laser Devices.................................................................................................................. A-5
Laser Safety Warnings .............................................................................................A-6
Compliance with CDRH Regulations ......................................................................A-6
Compliance with International Regulations ............................................................. A-6
Laser Product Label.................................................................................................. A-6
Laser Information.....................................................................................................A-7
Battery Replacement Notice ........................................................................................... A-7
Power Cords.................................................................................................................... A-8
Mouse Compliance Statement ........................................................................................A-9
Appendix B
Electrostatic Discharge
Preventing Electrostatic Damage.................................................................................... B-1
Grounding Methods ........................................................................................................ B-2
Appendix C
Server Error Messages
Appendix D
Troubleshooting
When the Server Does Not Start.....................................................................................D-2
Diagnosis Steps...............................................................................................................D-4
Problems After Initial Startup.........................................................................................D-9
Other Information Resources........................................................................................D-13
Appendix E
LEDs, Switches, and Jumpers
Status Indicators.............................................................................................................. E-1
Front Panel LED Indicators...................................................................................... E-2
Rear Panel LED Indicators....................................................................................... E-3
System Board LEDs ................................................................................................. E-5
Switches.......................................................................................................................... E-6
System Maintenance Switch (SW2)......................................................................... E-6
Hot-Plug Redundant Power Supply/PCI Switch (SW1) Settings............................. E-8
Debug LED Switch (SW3) Settings......................................................................... E-8
vi HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
Clearing and Resetting System Password Settings ...................................................E-9
Clearing and Resetting System Configuration Settings............................................E-9
Setting the NIC Operating Mode ............................................................................ E-10
Appendix F
Server Specifications
Operating and Performance Specifications for the ProLiant DL360 Generation 3 ServerF-1
Appendix G
Battery
Battery Replacement ...................................................................................................... G-1
Index
Contents
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide vii
This guide is designed to be used as step-by-step instructions for installation and as a
reference for operation, troubleshooting, and future upgrades for the HP
ProLiant DL360 Generation 3 server.

Intended Audience

This guide is intended for anyone configuring an HP ProLiant DL360 Generation 3
server. A moderate level of server-based knowledge and experience is assumed.

Important Safety Information

Before installing this product, read the Important Safety Information document
provided.

About This Guide

Symbols on Equipment

The following symbols may be placed on equipment to indicate the presence of
potentially hazardous conditions:
WARNING: This symbol, in conjunction with any of the following symbols, indicates the presence of a potential hazard. The potential for injury exists if warnings are not observed. Consult your documentation for specific details.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide ix
About This Guide
Weight in kg Weight in lb
This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure.
This symbol on an RJ-45 receptacle indicates a network interface connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.
This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.
These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system.
This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.
WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling.
x HP ProLiant DL360 Generation 3 Server Setup and Installation Guide

Rack Stability

WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:
The leveling jacks are extended to the floor.
The full weight of the rack rests on the leveling jacks.
The stabilizing feet are attached to the rack, if it is a single-rack
installation.
The racks are coupled together in multiple-rack installations.
Only one component is extended at a time. A rack may become unstable if
more than one component is extended for any reason.

Symbols in Text

These symbols may be found in the text of this guide. They have the following
meanings.
WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life.
About This Guide
CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or loss of information.
IMPORTANT: Text set off in this manner presents clarifying information or specific
instructions.
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points of
information.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide xi
About This Guide

Related Documents

For additional information on the topics covered in this guide, refer to the following documentation:
HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide
ProLiant Servers Cabling Matrix: www.hp.com/servers/proliant/manage
HP ProLiant DL360 Generation 3 Server Hardware Installation and
Configuration Poster
Servers Troubleshooting Guide:
www.hp.com/servers/proliant/manage
HP ProLiant DL360 Generation 3 Server High-Density Deployment white paper
For general online reference and specifications, refer to
www.hp.com/servers/proliant

Getting Help

If you have a problem and have exhausted the information in this guide, you can get further information and other help in the following locations.

HP Technical Support

In North America, call the HP Technical Support Phone Center at 1-800-652-6672. This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. Outside North America, call the nearest HP Technical Support Phone Center. For telephone numbers of worldwide Technical Support Centers, refer to
Before calling, refer to the Servers Troubleshooting Guide for a list of information to have available.
Documentation CD or website
www.hp.com
xii HP ProLiant DL360 Generation 3 Server Setup and Installation Guide

HP Website

For information on this product, as well as the latest drivers and flash ROM images
www.hp.com.
go to

HP Authorized Reseller

For the name of your nearest HP authorized reseller:
In the United States, call 1-800-345-1518.
In Canada, call 1-800-263-5868.
About This Guide
Elsewhere, refer to
www.hp.com for locations and telephone numbers.

Reader’s Comments

HP welcomes your comments on this guide. Please send your comments and
suggestions by email to
ServerDocumentation@hp.com.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide xiii
Planning the Server Installation
If planning to deploy and configure multiple servers in a single rack, consult the HP
ProLiant DL360 Generation 3 Server High-Density Deployment white paper at
www.compaq.com/products/servers

HP ProLiant DL360 Generation 3 Server Features

For a list of features, which are standard on the HP ProLiant DL360 Generation 3
server, refer to
www.compaq.com/products/servers/proliantdl360
A generation identifier (G3), located on the front of the server, indicates the model of
the server purchased. The generation identifier is required to accurately identify the
model for service and support.
1

Server Installation Overview

The following steps give an overview of the required procedures for installing the
server:
IMPORTANT: Before beginning the following procedures, refer to the Important Safety Information guide that shipped with the server.
1. Select an appropriate site for the rack.
2. Unpack the server and rack-mounting hardware.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 1-1
Planning the Server Installation
3. Install PCI or PCI-X expansion boards (optional).
4. Install other options.
Other options include additional memory, hard drives, a second processor, a second hot-plug power supply, and external storage devices. Refer to Chapter 2, “Installing Hardware Options.”
Before running the System Configuration Utility, install hardware options. Installation of additional memory and most PCI boards can be done after the System Configuration Utility is run. The System Configuration Utility is run during the SmartStart portion of the installation sequence.
IMPORTANT: Do not attempt to change the factory settings for reserved switches. Inaccurate settings can seriously degrade system performance.
5. Set internal switches, if necessary. For detailed information on relevant switches,
refer to Appendix E, “LEDs, Switches, and Jumpers.”
6. Use the rack template to identify the proper location for server installation. Refer
to “Measuring with the Template,” in Chapter 3, “Server Installation.”
7. Install the universal rack rails. Refer to “Installing the Universal Rack Rails” in
Chapter 3, “Server Installation.”
8. Mount the server in the rack. Refer to “Installing the Server into the Rack,” in
Chapter 3, “Server Installation.”
9. Install the fixed cable tray for managing cables on the server rear panel.
These cables include keyboard, mouse, monitor, network, and power cables.
Refer to “Attaching the Fixed Cable Tray,” in Chapter 3, “Server Installation.”
10. Connect the power cord and peripheral devices. Refer to “Connecting the
Peripheral Device Cables and the Power Cord,” in Chapter 3, “Server
Installation.”
11. Secure the power cord and peripheral device cables in the fixed cable tray. Refer
to “Securing the Cables in the Cable Tray,” in Chapter 3, “Server Installation.”
1-2 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide

Optimum Environment

When installing these servers in a rack, select a location that meets the environmental
standards described in the following paragraphs.

Space and Airflow Requirements

To allow for servicing and adequate airflow, observe the following spatial
requirements when deciding where to install an HP-branded, Compaq-branded, telco,
or third-party rack:
Leave a minimum clearance of 63.5 cm (25 inches) in front of the rack.
Leave a minimum clearance of 76.2 cm (30 inches) in the back of the rack.
Leave a minimum clearance of 121.9 cm (48 inches) from the back of the rack to
the rear of another rack or row of racks.
The servers draw in cool air through the rack front door and expel warm air through
the rack rear door. Therefore, the front and rear rack doors must be adequately
ventilated to allow ambient room air to enter the front of the cabinet and warm air to
escape from the rear of the cabinet.
IMPORTANT: Do not block the ventilation openings.
Planning the Server Installation
Compaq branded 9000 and 10000 Series racks provide proper server cooling from
flow-through perforations in the front and rear doors that provide 64 percent open
area for ventilation.
CAUTION: When using a Compaq branded 7000 Series rack, the high airflow rack door insert must be installed [P/N 327281-B21 (42U) and P/N 157847-B21 (22U)] to provide proper front-to-back airflow and cooling.
CAUTION: When using a Compaq branded 7000 Series rack, an extension kit must be installed to allow sufficient clearance for cabling and cabling hardware at the back. Refer to information.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 1-3
www.compaq.com/quickspecs for part numbers and ordering
Planning the Server Installation
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If the 42U server rack includes closing front and rear
doors, 5,350 sq cm (830 square inches) of holes evenly distributed from top to bottom must be available to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels
of the rack must be a minimum of 7 cm (2.75 inches).
CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels, results in improper cooling that can lead to thermal damage.

Temperature Requirements

To ensure continued safe and reliable equipment operation, install or locate the system in a well-ventilated, climate-controlled environment.
The HP maximum recommended ambient operating temperature (TMRA) for most server products is 35°C (95°F). The temperature in the room where the rack is located must not exceed 35°C
(95°F).

Power Requirements

WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over the facility’s wiring and installation requirements.
The installation of this equipment shall be in accordance with local/regional electrical regulations governing the installation of information technology equipment by licensed electricians. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA 75, 1992 Edition (code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product’s rating label or the user documentation supplied with that option.
1-4 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
When installing more than one server, additional power distribution devices may be
required to safely provide power to all devices. Observe the following guidelines:
The power load must be balanced between available AC supply branch circuits.
The overall system AC current load must not exceed 80 percent of the branch
circuit AC current rating.

Grounding Requirements

For proper operation and safety, the server must be properly grounded. In the United
States, install the equipment in accordance with NFPA 70, 1999 Edition (National
Electric Code) Article 250, as well as any local and regional building codes. In
Canada, install the equipment in accordance with Canadian Standards Association,
CSA C22.1, Canadian Electrical Code. In all other countries, the installation must
follow any regional or national electrical wiring codes, such as the International
Electrotechnical Commission (IEC) 364, parts 1 through 7. Furthermore, ensure that
all power distribution devices used in the installation—such as branch wiring and
receptacles—are listed or certified grounding-type devices.
Because high ground leakage currents associated with multiple servers connected to
the same power source, HP recommends the use of a power distribution unit (PDU)
that is either permanently wired to the building’s branch circuit or includes a
non-detachable cord that is wired to an industrial-style plug. NEMA locking-style
plugs or those complying with IEC 60309 are considered suitable for this purpose.
HP does not recommend using common power outlet strips for this equipment.
Planning the Server Installation

Rack Planning Resources

For Rack Builder Pro Configuration Tool and Rack Products documentation, go to
www.compaq.com/rackbuilder
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 1-5
Planning the Server Installation

Rack Warnings and Cautions

Before installing a rack, carefully review the following warnings and cautions.
WARNING: To reduce the risk of personal injury or equipment damage, always ensure that the rack is adequately stabilized before extending a component out of the rack. Extend only one component at a time. A rack may become unstable if more than one component is extended for any reason.
WARNING: To reduce the risk of personal injury or equipment damage, ensure that:
The leveling jacks are extended to the floor.
The full weight of the rack rests on the leveling jacks.
The stabilizers are attached to the rack for single-rack installation.
The racks are coupled together in multiple-rack installations.
WARNING: When installing the server in a telco rack, ensure that the rack frame is adequately secured to the top and bottom of the building structure.
WARNING: To reduce the risk of personal injury or equipment damage, at least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as 115 kg (253 lb), can stand more than
2.1 m (7 ft) tall, and may become unstable when moved on its casters.
Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both sides.
CAUTION: Always begin by mounting the heaviest item on the bottom of the rack.
Continue to populate the rack from the bottom to the top.

Server Warnings and Cautions

Before installing the server, carefully review the following warnings and cautions.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
1-6 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
WARNING: To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an
important safety feature.
Plug the power cord into a grounded (earthed) electrical outlet that is
easily accessible at all times.
Unplug the power cord from the power supply to disconnect power to the
equipment.
CAUTION: Protect the server from power fluctuations and temporary interruptions
with a regulating uninterruptible power supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure.
CAUTION: Do not operate the server for long periods without the access panel. Operating the server without the access panel results in improper airflow and improper cooling that can lead to thermal damage.

Server Shipping Contents

Planning the Server Installation
Unpack the server box, and locate the materials and documentation for installing the
server. All rack-mounting hardware for installing the server into the rack is included
with the rack or the server.
In addition to these supplied items, the following items may be needed:
Application software diskettes
Options to be installed
Phillips screwdriver
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 1-7
2
Installing Hardware Options
This chapter provides information and procedures for installing hardware options on
HP ProLiant DL360 Generation 3 servers. For additional instructions, refer to the
installation documentation shipped with each option kit, the hardware installation and
configuration poster shipped with the server, and the labels attached to the inside of
the server access panel.
To streamline the installation process, read the installation instructions for all of the
hardware options and identify similar steps before beginning installation.
After installing all hardware options, proceed with the server installation procedures
in Chapter 3, “Server Installation.”
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 2-1
Installing Hardware Options

Accessing Internal Server Components

This section defines standard procedures to access the inside of the server. Procedures will vary depending on whether the server is in the rack and powered on or out of the rack.

Accessing Internal Components when the Server is out of the Rack

With the server not yet installed in the rack, accessing internal components requires the removal of the access panel.
Removing the Access Panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching them.
CAUTION: Before removing the server access panel, be sure that the server is
powered down and that the power cord is disconnected from the server or the electrical outlet.
CAUTION: Electrostatic discharge can damage electronic components. Be sure you are properly grounded before beginning any installation procedure.
To remove the access panel lift up on the hood latch, slide panel toward rear of server, and remove the panel.

Accessing Internal Components when the Server is in the Rack

The universal rack rail allows the mounting of either fixed or sliding rails. The sliding rail and cable management system option allows the ProLiant DL360 Generation 3 server to be mounted on sliding rails that support in-rack serviceability. Rack depths of 24 in (61 cm) to 36 in (91 cm) are supported. The cable management system provides a clean, effective way to route server cables.
2-2 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
Installing Hardware Options
To access internal components:
1. Power down the server.
a. Shut down the operating system as directed in the operating system
instructions.
CAUTION: Whenever installing hardware or performing maintenance procedures requiring access to internal components, it is recommended that all server data be backed up to avoid loss.
b. Press the unit identification button on the server front panel (1). An LED
illuminates blue on the server front and rear panels.
c. Press the server Power On/Standby button (2) to power down the server. The
Power On/Off LED (2) turns from green to amber indicating standby mode.
Figure 2-1: Activating the front unit identification LED
and powering down the server
2. If the server has a sliding rail solution:
a. Loosen the thumbscrews securing the server in the rack.
b. Slide the server out of the rack until the rail locks engage.
c. Disconnect the power cord.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 2-3
Installing Hardware Options
d. Remove the access panel. Refer to the “Removing the Access Panel” section
earlier in this chapter.
3. If the server has a universal rail solution:
a. Disconnect the power cord and cables from the server rear panel (including
cables extending from expansion boards), moving from left to right.
b. Loosen the server thumbscrews securing the cable tray to the universal rack
rail and to the server (1) and remove the cable tray from the server (2).
Figure 2-2: Removing the cable tray from the server
2-4 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
Installing Hardware Options
c. Move to the front of the rack and loosen the thumbscrews securing the server
in the rack (1).
d. Grasp the front panel thumbscrews, and extend the server from the rack. The
cables remain clamped in the cable tray. The rail release latches engage automatically.
e. Press in and hold the rail release latches (2).
f. Holding the rail release latches, extend the server until the latches clear the
rack.
g. Pull the server completely out of the rack and set it on a flat, level
surface (3).
Figure 2-3: Removing the server from the rack
h. Remove the access panel. Refer to the “Removing the Access Panel” section
earlier in this chapter.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 2-5
Installing Hardware Options

Identifying System Board Components

Use the following figure and table to locate the system board and to identify the system board connectors and components for option installation or service events.
Figure 2-4: Identifying system board components
2-6 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
Installing Hardware Options
Table 2-1: System Board Connectors and Components
Item Description Item Description
1 PCI riser board slot 1 connector 10 Power signal connector
2 Battery 11 System power connector
3 DIMM slots (four) 12 PPM socket 2
4 Processor Power Module (PPM)
socket 1 (shown with PPM installed)
5 Processor 1 socket (shown with
processor/heatsink installed)
6 Processor 2 socket 15 Redundant Power Supply/PCI install
7 Fan board connector 16 PCI riser board slot 2 connector
8 SCSI board connector 17 System maintenance switch (SW2)
9 Optical device/floppy board signal
connector
13 Smart Array 5i memory connector
14 Debug LED switch bank (SW3)
switch bank (SW1)

Installing Additional Memory

Server memory can be expanded by installing Double Data Rate Synchronous
DRAM (DDR SDRAM). The system supports up to four PC2100 ECC registered
DDR SDRAM Dual Inline Memory Modules (DIMMs) installed in four sockets on
the system board. Memory must be added two equivalent modules at a time.
Refer to Figure 2-4 and to Table 2-1 for DIMM slot location and socket numbers.
This information is also available on the hood label. Memory must be installed in the
lowest DIMM socket number to the highest.
The following guidelines must be observed when installing additional memory:
DIMMs installed in the server must be PC2100 registered DDR SDRAM, 3.3 V, 64 bits wide, and ECC.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 2-7
Installing Hardware Options
All DIMMs installed must be the same speed. Do not install DIMM modules supporting different speeds. For example, DIMM modules supporting speeds of 266 MHz and 200 MHz should not be installed together.
To facilitate successive DIMM installations, install the DIMMs in ascending sequential order, starting with DIMM socket 1A.
DIMMs are installed in banks of two DIMMs per bank. Bank A is DIMMs 1 and 2, and Bank B is DIMMs 3 and 4.
CAUTION: Use only HP DIMMs. DIMMs from other sources can adversely affect data integrity.
Refer to www.compaq.com/quickspecs for DIMM option kits.
CAUTION: Electrostatic discharge can damage electronic components. Be sure you are properly grounded before beginning any installation procedure. Refer to Appendix B, “Electrostatic Discharge,” for more information.
To install a DIMM onto the system board:
1. Access internal server components. Refer to “Accessing Internal Server Components” section earlier in this chapter.
2. Open the DIMM socket latches.
3. Align the key slot in the bottom edge of the DIMM with the tab in the expansion
socket.
4. Insert the DIMM at the same angle as the DIMM socket on the system board. As the DIMM enters the socket, the latches close.
IMPORTANT: Misaligned DIMMs do not seat.
5. Press down firmly on the DIMM while pushing the latches inward until the latches snap into place.
6. Reverse the procedures performed in the “Accessing Internal Server Components” section earlier in this chapter.
2-8 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide

Replacing an Expansion Board

To install an expansion board, complete the procedures described in the following subsections.

Removing an Expansion Board

The expansion board and PCI riser board assembly must be removed to replace an expansion board.
CAUTION: To avoid damaging the system or expansion boards, remove all AC power cords before installing or removing an expansion board. When the front panel power switch is in the Off position, auxiliary power is still connected to the PCI expansion slot and may damage the card.
1. Access internal server components. Refer to the “Accessing Internal Server
Components” section earlier in this chapter.
2. Disconnect any cables leading from any existing expansion board in the system
board.
Installing Hardware Options
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 2-9
Installing Hardware Options
3. Loosen the PCI riser board thumbscrew (1).
4. Lift the front of the assembly slightly (2) and then pull it out of the server chassis
PCI support slot (3).
Figure 2-5: Removing the PCI riser board assembly and expansion board from PCI expansion board slot 1
5. Remove expansion board from PCI riser board assembly.
2-10 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
Installing Hardware Options

Inserting an Expansion Board into the PCI Riser Board Assembly

To install an expansion board:
CAUTION: Do not discard the expansion slot cover. If the PCI expansion board is removed in the future, the expansion slot cover must be reinstalled to maintain proper cooling.
CAUTION: When installing an expansion board with a mezzanine board attached, remove the bracket between the two boards.
NOTE: The PCI slots only accept 3.3 volt or universal PCI expansion boards. Expansion boards that are 5 volt cannot be used in this server.
1. Remove the expansion slot cover from the PCI riser board assembly (1).
2. Align the expansion board with the guiding groove.
3. Slide the expansion board into the slot until the board seats firmly (2).
Figure 2-6: Installing an expansion board into the PCI riser board
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide 2-11
Loading...
+ 88 hidden pages