HP MSM310 Quick Start Manual

Page 1
In
VIEW Certified
The MSM310 is a Wi-Fi Alliance authorized Wi-Fi CERTIFIED 802.11a/b/g product. The Wi-Fi CERTIFIED Logo is a certification mark of the Wi-Fi Alliance. The MSM310 is certified under the SpectraLink Voice Interoperability for Enterprise Wireless (VIEW) Certification Program when it operates in autonomous mode or in controlled mode in conjunction with an MSM7xx Controller.
This Quickstart shows you how to get started using the MSM310 Access Point (US J9374A/B, WW J9379A/B).
After reading this Quickstart, you can visit www.hp.com/go/procurve/manuals and download documents of particular interest such as the MSM3xx / MSM4xx Access Points Management and Configuration Guide and the MSM7xx Controllers Management and Configuration Guide.
Hardware overview
MSM310 Access Point Quickstart
Package contents
MSM310, documentation, two 2.4-GHz (2-dBi) / 5-GHz (2-dBi) dual-mode omnidirectional antennas.
Reset button
Press and quickly release the button to reset the MSM310. To reset to factory default settings, press and hold the reset button until the status lights flash three times, then release. For details, see Resetting to factory defaults in the MSM3xx / MSM4xx Access Points Management and Configuration Guide.
Note: To reconnect to the management tool after a factory reset, your computer must be
connected to Ethernet Port 1.
Radio and antennas
The MSM310 has a single radio with two antennas for diversity.
The antenna connectors are reverse-polarity SMA jacks. Antennas or cable connectors must use RP-SMA plugs. Antennas can be mounted directly on the MSM310. When a single antenna is used, it is recommended to connect it to the Main antenna connector.
Optional external antennas are available from HP ProCurve. On the HP ProCurve Website, see the Accessories section for the MSM310.
Ethernet ports
The MSM310 has two 10/100 Mbps Ethernet ports with RJ-45 connectors. Port 1 supports Power over Ethernet (PoE) 802.3af. In controlled mode, Port 1 should be used. In autonomous mode, Port 1 or Port 2 can be used.
Page 2
MSM310 Access Point Quickstart 2 HP ProCurve Networking
About controlled mode and autonomous mode
The MSM310 can operate in one of two modes: controlled (the default) or autonomous. Switching modes resets all configuration settings to factory defaults.
Controlled mode: To become operational, the MSM310 must establish a management
tunnel with an MSM7xx Controller via Ethernet Port 1 (do not use Port 2 in controlled mode). The controller manages the MSM310 and provides all configuration settings. Discovery of the service controller is automatic if default settings are used on the MSM310 and the controller, and both devices are on the same subnet. See Working with controlled APs in the MSM7xx Controllers Management and Configuration Guide.
Autonomous mode: Once switched to autonomous mode, the MSM310 operates as a
stand-alone AP. An autonomous MSM310 is configured and managed via its web-based management tool as described in Initial configuration (autonomous mode) on page 3.
Status light behavior in controlled mode
During startup/discovery in controlled mode, the MSM310 status lights provide the following information:
Status light behavior Description
Power light blinks once every two seconds. The MSM310 is starting up.
Power light blinks once per second. The MSM310 is looking for an IP address, or
building the list of VLANs on which to perform discovery. The management tool is available until discovery occurs.
Power light, Ethernet light, and Radio light blink in sequence from left to right.
Power light is on. Radio and Ethernet lights blink alternately until the secure management tunnel is established.
Power light and Radio light blink alternately and quickly. Ethernet light is off.
Power light and Radio light blink slowly. The MSM310 is attempting to establish a
Power light and Ethernet light blink slowly. The MSM310 is attempting to establish wired
Once the discovery process is complete, and the MSM310 has established a secure management tunnel to a controller, the Power light remains on and the Ethernet and Radio lights blink to indicate the presence of traffic.
The MSM310 has obtained an IP address and is attempting to discover a controller.
The MSM310 has found a controller and is attempting to establish a secure management tunnel with it.
The MSM310 has received a discovery reply from two or more controllers with the same priority setting. The MSM310 is unable to connect with either controller until the priority conflict is resolved.
local mesh link to a master node.
connectivity.
Status light behavior in autonomous mode
In autonomous mode, the status lights provide the following information:
Light State Description
Power Off The MSM310 has no power.
Blinking The MSM310 is starting up. If the Power light continues to
blink after several minutes, it indicates that the software failed to load. Reset or power cycle the MSM310. If this condition persists, contact HP ProCurve Customer Care.
On The MSM310 is fully operational.
Ethernet Off The port is not connected or there is no activity.
Blinking The port is transmitting or receiving data.
Radio Blinking The radio is transmitting or receiving data.
Important information to read before installing
Warning: PROFESSIONAL INSTALLATION REQUIRED. For indoor installation only.
Prior to installing or using the MSM310, consult with a professional installer trained in RF installation and knowledgeable in local regulations including building and wiring codes, safety, channel, power, indoor/outdoor restrictions, and license requirements for the intended country. It is the responsibility of the end user to ensure that installation and use comply with local safety and radio regulations.
Surge protection and grounding: If you plan on connecting an outdoor antenna to the
MSM310, make sure that proper lightning surge protection and grounding precautions are taken according to local electrical code. Failure to do so may result in personal injury, fire, equipment damage, or a voided warranty. The HP ProCurve hardware warranty provides no protection against damage caused by static discharge or a lightning strike.
Cabling: You must use the appropriate cables, and where applicable, surge protection, for your given region. For compliance with EN55022 Class-B emissions requirements, use shielded Ethernet cables.
Plenum installation: The MSM310 can be installed in a plenum (UL2043 rating). It should be installed in a similar orientation as in a ceiling installation. However, it is left to a qualified installer to determine how to install/secure the MSM310 in a plenum in an appropriate and safe manner. Plenum-rated cables and attachment hardware must be used.
Country of use: In some regions, you are prompted to select the country of use during setup. Once the country has been set, the MSM310 will automatically limit the available wireless channels, ensuring compliant operation in the selected country. Entering the incorrect country may result in illegal operation and may cause harmful interference to other systems. See Regulatory Notice for European Union and EFTA member countries on page 5.
Page 3
MSM310 Access Point Quickstart 3 HP ProCurve Networking
Caution: External Antennas: When using an external antenna, depending on the
country of use, the antenna selected, and your radio settings, it may be mandatory to reduce the radio transmission power level to maintain regulatory compliance. For specific power limits for your country, consult the Antenna Power-Level Setting Guide available on the HP ProCurve manuals page for the MSM3xx/4xx Access Points at www.hp.com/go/procurve/manuals.
To set the radio transmission power level, for controlled access points see Transmit power control in the MSM7xx Controllers Management and Configuration Guide. For autonomous access points, see Transmit power control in the MSM3xx / MSM4xx Access Points Management and Configuration Guide.
Safety: Take note of the following safety information during installation:
If your network covers an area served by more than one power distribution system, be
sure all safety grounds are securely interconnected.
Network cables may occasionally be subject to hazardous transient voltages (caused by
lightning or disturbances in the electrical power grid).
Handle exposed metal components of the network with caution.
The MSM310 is powered-on when Ethernet Port 1 is plugged into a PoE power source
or when an external power supply is connected.
The MSM310 and all interconnected equipment must be installed indoors within the
same building (except for outdoor models / antennas), including all PoE-powered network connections as described by Environment A of the IEEE 802.3af standard.
Installation
When mounting the MSM310 on a wall or ceiling, ensure that the surface to which you attach the MSM310 and the fasteners you use can support at least .9 kg (2 pounds). Allow extra weight for cables.
If you intend to install the MSM310 in a plenum, see Plenum installation under Important information to read before installing on page 2.
Powering the MSM310
The MSM310 can be powered by:
A PoE-enabled switch. Various PoE-enabled switches are available from HP ProCurve.
An HP ProCurve 1-Port Power Injector (J9407A).
An HP ProCurve MSM31x Power Supply (J9405A).
Note: For controlled mode configuration, instead see Working with controlled APs in the
MSM7xx Controllers Management and Configuration Guide.
In autonomous mode, the MSM310 is managed via its web-based management tool using at least Microsoft Internet Explorer 7/8 or Firefox 3.x.
Caution: Wireless Security
For initial configuration convenience, a factory-default MSM310 that has been switched to autonomous mode has all wireless security options disabled. It is strongly recommended that after performing this procedure, you enable a wireless security option to properly safeguard the wireless network from intruders. See Wireless protection in the MSM3xx / MSM4xx Access Points Management and Configuration Guide.
Note: Do not power on the MSM310 until directed.
A. Configure your computer
1. Disconnect your computer LAN port and configure it to use a static IP address in the
range 192.168.1.2 to 192.168.1.254, and a subnet mask of 255.255.255.0. Set the default gateway to 192.168.1.1, and DNS server to 192.168.1.1. For example to do this in Windows Vista, use Control Panel > Network and Sharing Center > Manage Network
Connections > Local Area Connection, right-click Properties then select Internet Protocol Version 4 (TCP/IPv4) > Properties.
2. Disable any wireless connection on your computer.
B. Connect the cables and power on the MSM310
1. Connect the cables:
If using a PoE switch, use standard Ethernet cables to connect your computer and the
MSM310 to an unused factory-default PoE switch.
If using a PoE injector, use a crossover Ethernet cable to connect your computer to
the data in port of the PoE injector and a standard Ethernet cable to connect the MSM310 to the data and power out port of the PoE injector.
If you are using a power supply, use a crossover Ethernet cable to connect your
computer to the MSM310 Ethernet port.
2. Power on the MSM310:
If using a PoE switch or injector, power it on.
If using a power supply, connect it to the MSM310 then power on the supply.
Initially, the MSM310 power light will blink once every two seconds. Wait approximately a minute until it begins blinking once per second before proceeding to the next step.
Initial configuration (autonomous mode)
This procedure describes how to switch a factory-default MSM310 to autonomous mode and then perform its initial configuration that enables you to establish a wireless connection through the MSM310 to the Internet.
C. Switch the MSM310 to autonomous mode
Note: A factory-default MSM310 is assumed.
1. In a Web browser enter the address: https://192.168.1.1.
2. A security certificate warning is displayed the first time you connect to the management
tool. This is normal. Select whatever option is needed in your Web browser to continue
Page 4
MSM310 Access Point Quickstart 4 HP ProCurve Networking
to the management tool. The security warning will not appear again unless you change the IP address of the MSM310.
3. On the Login page, specify admin for both Username and Password and then select
Login. The MSM310 management tool home page opens.
4. Select Switch to Autonomous Mode and confirm the change. The MSM310 restarts in
autonomous mode.
Note: To avoid a delay after switching modes, clear the ARP (address
resolution protocol) cache on your computer. In Windows for example, from the Windows Start menu, select Run and enter “arp -d” (without the quotes). Select OK.
D. Log in
1. Wait until the Power light stops blinking and remains on.
2. On the Login page, specify admin for both Username and Password and select Login.
3. On the License Agreement page, read the agreement and select Accept License
Agreement.
4. The registration page appears. It is recommended that you register later by selecting
Maintenance > Registration.
5. If a Country prompt appears, select the country in which the MSM310 will operate.
Caution: The correct country must be selected. See Country of use on page 3.
6. At the password prompt it is recommended that you change the default password and
select Save. Passwords must be at least six characters long and include four different characters.
The management tool is organized with menus and sub-menus. Instructions for making menu selections, such as “select Wireless > Local mesh” instruct you to select the Wireless menu and then the Local mesh sub-menu, as follows:
E. Assigning an IP address to the MSM310
By default the MSM310 operates as a DHCP client. This means that if the network has a DHCP server, the MSM310 will automatically receive a new IP address in place of its default address of 192.168.1.1 upon connecting to the network. Use one of the following methods to assign an IP address to the MSM310:
Pre-configure the DHCP server to assign a specific IP address to the MSM310. To do
this you need to specify the MSM310 Ethernet MAC address and a reserved IP address on the DHCP server. The MSM310 Ethernet MAC address is printed on the MSM310 label identified as Ethernet Base MAC, and listed on the management tool Home page as Ethernet base MAC address.
Let the DHCP server automatically assign an IP address. By default, the DHCP server
will assign an IP address once the MSM310 connects to the network. Once the DHCP server has assigned the MSM310 an IP address, you can then find the IP address of the MSM310 by looking for its Ethernet base MAC address in the DHCP server log. For example after Step F.4 below, you could go to the DHCP server log to retrieve the IP address assigned to the MSM310.
Assign a static IP address to the MSM310. The address must be on the same subnet as
the network to which the MSM310 will connect.
1. Select Network > DNS, and set the DNS server address. Select Save.
2. Select Network > Ports > Bridge port.
3. Select Static and then Configure. Configure settings as follows:
IP address: Set an address that is on the same subnet as the network to which
the MSM310 will connect once installed. Respect any DHCP server-mandated static address ranges.
Mask: Set the corresponding mask for the IP address.
Default gateway: Set the IP address of the gateway on the network.
4. Select Save. Connection to the management tool is lost.
F. Test the wireless network
For the purposes of this procedure, the network must have a DHCP server and an Internet connection. Broadband routers typically include a DHCP server.
1. Disconnect your computer from the PoE switch or injector or the MSM310.
2. Power off the MSM310:
If using a PoE switch or injector, disconnect the Ethernet cable from the MSM310.
If using a power supply, disconnect it.
3. Use a standard Ethernet cable to connect the switch or the data in port of the injector to
the network.
4. Reconnect and power on the MSM310:
If using a PoE switch or injector, use a standard Ethernet cable to reconnect the
MSM310 to the PoE switch or the data and power out port of the injector.
If using a power supply, use a standard Ethernet cable to connect the MSM310 to the
network, and reconnect the MSM310 power supply.
5. Enable the wireless network interface of your computer, and verify that it is set to obtain
an IP address automatically. For example, to do this in Windows Vista, use Control Panel > Network and Sharing
Center > Manage Network Connections > Wireless Network Connection, right-click Properties and select Internet Protocol Version 4 (TCP/IPv4) > Properties, and make sure that Obtain an IP address automatically and Obtain a DNS server address automatically are both enabled.
Page 5
MSM310 Access Point Quickstart 5 HP ProCurve Networking
6. By default, the MSM310 creates a wireless network named HP ProCurve. Connect your
computer to this wireless network. For example, in Windows Vista from the Start menu, select Connect to, and then HP ProCurve from the list of available wireless networks. You may have to wait a short time for this wireless network name to appear in the wireless networks list.
7. Confirm that you can browse the Internet using the wireless network.
G. Performing additional configuration
Configure your computer LAN port and connect it to the same network as the MSM310. Re­launch the MSM310 management tool at https://<IP address> where <IP address> is the MSM310 IP address from Step E above.
Note: See the Caution regarding WIRELESS SECURITY on page 3.
Enabling access to other resources
By default, the MSM310 only permits traffic that is addressed to the default gateway on the network (which enables you to connect to the Internet). To enable access to other resources:
1. Select VSC > Profiles and then select the HP ProCurve profile.
2. On the Add/Edit Virtual Service Community page clear the Wireless security filters
checkbox.
3. Select Save.
Regulatory Notice for European Union and EFTA member countries
As of July 1st 2010, all wireless devices sold in EU countries and any countries that participate in the EU free market must meet stringent Dynamic Frequency Selection (DFS) requirements for radar detection and avoidance (EN 301.893 v1.5.1). The MSM310 is compliant.
Compliance notes
Software version 5.3.5 is released for both rev A and rev B MSM310 APs.
On the rev A MSM310, the 5 GHz DFS channels are enabled and can be used.
On the rev B MSM310, the following additional 5 GHz DFS channels are disabled and cannot be used:
Channels 52, 56, 60 and 64 in the 5250-5350 MHz band
Channels 100, 104, 108, 112, 116, 132, 136 and 140 in the 5470-5725 MHz band.
Note: Customers will not have to disable these 5 GHz DFS channels on rev A MSM310
APs received prior to July 1st, 2010.
For non-EU/EFTA customers using the WW version of the MSM310, there is no change to the availability of DFS channels.
Page 6
MSM310 Access Point Quickstart 6 HP ProCurve Networking
© Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
February 2010 Printed in Document part # 5998-0469
*5998-0469*
Loading...