Contents

About This Guide
Audience Assumptions..................................................................................................................................v
Technician Notes...........................................................................................................................................v
Where to Go for Additional Help.................................................................................................................vi
Telephone Numbers...............................................................................................................................vi
Chapter 1
Illustrated Parts Catalog
Chapter 2
Identifying Enclosure and Component Features
Buttons and LEDs on Enclosure Rear....................................................................................................... 2-1
Disk Drives and Drive Blanks................................................................................................................... 2-2
Controller Module ..................................................................................................................................... 2-4
Fan Assembly............................................................................................................................................ 2-5
Power Supply Unit .................................................................................................................................... 2-6
Chapter 3
Removing and Replacing Components
Preventing Electrostatic Damage .............................................................................................................. 3-1
Grounding Methods ............................................................................................................................ 3-1
Replacement Procedures for Hot-Pluggable Components ........................................................................ 3-2
Disk Drive or Drive Blank.................................................................................................................. 3-2
Fan Assembly ..................................................................................................................................... 3-3
Power Supply Unit.............................................................................................................................. 3-3
Controller Module............................................................................................................................... 3-4
Battery Packs and Cache (in the Controller Module) ......................................................................... 3-4
Mounting Bracket Covers................................................................................................................... 3-6
Replacement Procedures for Non-Hot-Pluggable Components ................................................................ 3-6
Midplane Board .................................................................................................................................. 3-7
Backplane Board................................................................................................................................. 3-9
Ribbon Cable ...................................................................................................................................... 3-9
UID Circuit Board ............................................................................................................................ 3-10
VRM Power Supply.......................................................................................................................... 3-10
HP StorageWorks Modular Smart Array 20 Maintenance and Service Guide iii
Contents
Chapter 4
Specifications
Power Specifications..................................................................................................................................4-1
Environmental Specifications ....................................................................................................................4-1
Physical Specifications ..............................................................................................................................4-2
iv HP StorageWorks Modular Smart Array 20 Maintenance and Service Guide
This maintenance and service guide can be used for reference when servicing the HP StorageWorks Modular Smart Array 20 enclosure.
WARNING: To reduce the risk of personal injury from electric shock and hazardous energy levels, only authorized service technicians should attempt to repair this equipment. Improper repairs can create conditions that are hazardous.

Audience Assumptions

This guide is for service technicians. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazard in products with hazardous energy levels and are familiar with weight and stability precautions for rack installations.

Technician Notes

WARNING: Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
WARNING: To reduce the risk of personal injury from electric shock and hazardous energy levels, do not exceed the level of repairs specified in these procedures. Because of the complexity of the individual boards and subassemblies, do not attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create conditions that are hazardous.
WARNING: To reduce the risk of electric shock or damage to the equipment:
Disconnect power from the system by unplugging all power cords from the power
supplies.
Do not disable the power cord grounding plug. The grounding plug is an important
safety feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily
accessible at all times.

About This Guide

HP StorageWorks Modular Smart Array 20 Maintenance and Service Guide v
About This Guide
CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in.) of clearance at the front and back of the enclosure.
CAUTION: The enclosure is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only.
NOTE: Any indications of component replacement or printed wiring board modifications may void any warranty.

Where to Go for Additional Help

In addition to this guide, the following information sources are available:
User documentation
Service Quick Reference Guide
Service training guides
Service advisories and bulletins
QuickFind information services
Systems Insight Manager software

Telephone Numbers

For the name of the nearest HP authorized reseller:
In the United States, call 1-800-345-1518.
In Canada, call 1-800-263-5868.
For HP technical support:
In the United States and Canada, call 1-800-633-3600.
Outside the United States and Canada, refer to
http://www.hp.com.
vi HP StorageWorks Modular Smart Array 20 Maintenance and Service Guide
Illustrated Parts Catalog
The spare parts for the enclosure are illustrated on the following page.
1
HP StorageWorks Modular Smart Array 20 Maintenance and Service Guide 1-1
Illustrated Parts Catalog
Figure 1-1: Enclosure parts
1-2 HP StorageWorks Modular Smart Array 20 Maintenance and Service Guide
Illustrated Parts Catalog
Item Description Spare part number
1 Chassis Not spared
2 Power supply unit 349800-001
3 Fan assembly 349798-001
4 Button and LED panel Not spared
5 UID circuit board 361183-001
6 Controller module Module shell (sheet metal) with controller board,
349797-001 Upper battery pack with cable, 349799-001 Lower battery pack, 307132-001 Cache board with battery, 309521-001
7 Enclosure lid Not spared
8 VRM power supply 361741-001
9 Midplane 349795-001
10 Backplanes (two identical boards
per enclosure)
11 Mounting bracket cover (bezel ear) 349801-001 (supplied in a kit with item 14)
12 Hard drive Not spared as part of enclosure
13 Drive blank Not spared as part of enclosure
14 Mounting bracket cover (bezel ear) 349801-001 (supplied in a kit with item 11)
15 Ribbon cable (connects item 5 to
item 9)
Not shown
Return kit 349803-001
361740-001
361739-001
HP StorageWorks Modular Smart Array 20 Maintenance and Service Guide 1-3
Loading...