QuickSpecs
HPE Smart Array P721m Controller

Overview

Page 1
HPE Smart Array P721m Controller
The HPE Smart Array P721m is a PCI-Express (PCIe) 3.0 mezzanine card supporting direct attached and Shared SAS Storage for the Gen8 Blade servers through its support of the latest SCSI technology and advanced RAID capabilities. The P721m can support up to 227 zoned direct attached SAS or SATA hard drives per controller. This controller can support t to 4 P2000 G3 SAS array systems), and direct attach to D2600, D2700, D6000 and MDS600.
What's New
Support for HPE MSA2040 Storage
Models
HP Smart Array P721m/2GB FBWC 6Gb 4-ports Ext Mezzanine SAS Controller
650072-B21
HP Smart Array P721m/512 FBWC 6Gb 4-ports Ext Mezzanine SAS Controller
655636-B21
NOTE: HPE Smart Array P721m/512M Controller is only for shared storage connectivity. For connecting
SmartCache features enabled by default.
HPE ProLiant Gen8 BladeSystem servers. It provides new levels of reliability, connectivity, and storage performance for HPE
ape drives, shared storage (up
D2600/D2700/D6000 or MDS600, one must use P721m/2G FBWC controller.
NOTE: HPE Smart Array P721m/2G FBWC controller comes with Smart Array Advanced Pack 2.0 and HPE
Page 2
QuickSpecs
HPE Smart Array P721m Controller

Standard Features

Page 2
The Smart Array Advantage
The Hewlett Packard Enterprise innovative design and integration work within the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HPE Smart Array family brings an unparalleled return on investment.
Data Compatibility. Data Compatibility with all Serial Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase.
Consistent Configuration and Management Tools. All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain HPE server storage.
Pre-Failure Warranty. Pre-Failure Warranty means Systems Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HPE Support Center or refer to your HPE Server documentation.
Key Features
Storage interface (SAS/SATA)
gy
read performance by bypassing the Smart Array firmware for the optimal performance path to
nse is not required
Online Management Features
Online array expansion
Online and high performance offline Rapid Parity Initialization (RPI)
o Eight (8) 6Gb/s SAS physical links distributed equally across 4 external 2x ports to
support up to 4 6Gb/s SAS Switches
o 6Gb/s SAS technology delivers up to 600 MB/s theoretical bandwidth per physical
link.
o 6Gb/s SATA technology delivers up to 600 MB/s theoretical bandwidth per physical
link for directly attached SATA drives.
o Mix-and-match SAS and SATA drives to the same controller. Deploy drive technolo
as needed to fit the computing environment.
o Support for SAS tape drives, SAS tape autoloaders and SAS tape libraries.
RAID controller features
o 512 MB or 2 GiBytes cache o RAID 0, 1, 10, 5, 50, 6, 60, 1 ADM, 10 ADM
NOTE: RAID for Shared Storage is controlled by the controller of the array.
o Recovery ROM protects against ROM corruption.
Smart Array PCIe mezzanine card that connects to a HPE 6Gb/s SAS BL Switch through the c-
Class enclosure high-speed mid-plane supporting shared SAS storage.
2 GiBytes Flash Backed Write Cache (FBWC) provides read ahead caching and write back
caching with indefinite write cache data retention in the case of unexpected power outage.
Software consistency on most current shipping Smart Array family products: HPE
SmartStorage Administrator, HPE Systems Insight Manager, and HPE Intelligent Provisioning. The HPE Smart Storage Administrator configures and manages a host of Smart Array controllers and other storage devices using a single interface. It replaces the HPE Array Configuration Utility (ACU) with an updated design and configuration enhancements.
The HPE SSD Smart Path feature included in the Smart Array software stack improves SSD
the SSD.
The HPE SmartCache licensed feature is a controller-based read caching solution in a DAS
environment that caches the most frequently accessed data ("hot" data) onto lower latency SSDs to dynamically accelerate application workloads. HPE Smart Cache lice on P721m with 2GiBytes FBWC. HPE Smart Cache requires a minimum of 1 GiByte FBWC.
Online capacity expansion
Online logical drive extension
Online RAID level migration
Online stripe size migration
Online mirror split, recombine, and rollback
Page 3
QuickSpecs
HPE Smart Array P721m Controller
Standard Features
Page 3
Unlimited global online spares assignment
Performance
Eight (8) 6Gb/s SAS physical links distributed across 4 external 2x ports which supports up to
Capacity
Dependent upon attached arrays. See drive enclosure QuickSpecs for details
Availability
Provides increased server uptime by providing advanced storage functionality:
Fault Prevention
The following features offer detection of possible failures before they occur, allowing preventive action to be taken:
Fault Tolerance RAID Descriptions
Keeps data available and server running while a failed drive is being replaced; two fault tolerance configurations are supported for the internal connections including:
(Distributed Data Guarding): Supported with a minimum of 3 drives. This allocates one
RAID 50
User selectable expand and rebuild priority
User selectable RAID level and stripe size
User selectable read and write cache sizes
Supports Predictive Spare Activation
four 6Gb/s SAS Switches
6Gb/s SAS (600MB/s theoretical bandwidth per physical link)
PCIe 3.0
Up to 2 GiBytes Flash Backed Write Cache
Online RAID level migration between any RAID levels
Online stripe size migration
Online capacity expansion
Online logical drive extension
Online active drive replacement
Unlimited global online spare
S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at HPE detects
possible hard disk failure before it occurs, allowing replacement of the component before failure occurs.
Drive Parameter Tracking monitors drive operational parameters, predicting failure and
notifying the administrator.
Dynamic Sector Repairing continually performs background surface scans on the hard disk
drives during inactive periods and automatically remaps bad sectors, ensuring data integrity.
Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure
preventative maintenance.
RAID 6 (Advanced Data Guarding): Supported with a minimum of 4 drives. This allocates two
sets of parity data across drives. This level of fault tolerance can withstand a double drive failure without downtime or data loss.
RAID 60: Supported with a minimum of 8 drives. This volume is composed of two or more
RAID 6 sub-volumes (parity groups) where data is striped across each parity group as if it were a single physical drive. Each RAID 6 parity group can sustain up to two drive failures without incurring data loss.
RAID 5
set of parity data across drives. This level of fault tolerance can withstand a single drive failure without downtime or data loss.
: Supported with a minimum of 6 drives. This volume is composed of two or more
Page 4
QuickSpecs
HPE Smart Array P721m Controller
Standard Features
Page 4
RAID 5 sub-volumes (parity groups) where data is striped across each parity group as if it were a single physical drive. Each RAID 5 parity group can sustain a single drive failure without
drive array to the data and the other half to the mirrored data, providing two copies of the
Fault Recovery
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure:
corruption. A new version of firmware can be flashed to the ROM while the controller maintains
n of firmware. If the firmware becomes corrupt, the controller will
Ease of Use
Consistency and upgradeability on most shipping HPE Smart Array products make them unique in the industry:
HPE SmartCache
HPE SmartCache is a controller-based read caching solution in a DAS environment that caches the most frequently accessed data ("hot" data) onto lower latency SSDs to dynamically accelerate application workloads. The Gen8 supported HDD for bulk storage and any
HPE
The basic
For more information please visit http://www.hp.com/go/smartcache
HPE SSD Smart Path
The HPE SSD Smart Path feature included in the Smart Array software stack improves Solid State Disk (SSD) read performance. With up to 4x better SS
SSD Smart path chooses the optimum path to the SSD and accelerates reads for all RAID levels and RAID 0 writes. It is configurable through the archite
SSD Smart Path is ideal for read intensive workloads and is included as a base feature on SSD Smart Path feature:
incurring data loss.
RAID 1 & 10 (Drive Mirroring): Supported with a minimum of 2 drives. This allocates half of
the data.
RAID 1 ADM & 10 ADM (Advanced Data Mirroring): Supported with a minimum of 3 drives.
RAID 1 ADM creates redundant copies of the data using 3 drives. RAID 10 ADM stripes data across two or more sets of RAID 1 ADM volumes. This level of fault tolerance can withstand a double drive failure within a RAID 1 ADM volume without downtime or data loss.
Recovery ROM: This feature provides unique redundancy that protects from a ROM image
the last known working versio revert back to the previous version of firmware and continue operating. This reduces the risk of flashing firmware to the controller.
DRAM ECC corrects against single bit data and address corruption.
GUI based configuration, management and diagnostic software tools
Common data format between generations of products
HPE SmartCache architecture is flexible and supports any HPE ProLiant
HPE ProLiant Gen8 supported SSD as an accelerator.
SmartCache is deployed and managed using the HPE SmartStorage Administrator (HPE SSA).
HPE SmartCache architecture is comprised of the following three elements:
Bulk storage: The first element is the bulk storage device, which is any supported HDD
attached to the HPE Smart Array controller.
Accelerator: The second element, the accelerator, is a faster/lower latency SSD device that
caches data.
Metadata: The final element is metadata, information held in a relatively small storage area
that maps the location of information residing on the accelerator and bulk storage devices.
D read performance, HPE
HPE SmartStorage Administrator providing seamless management with the Smart Array
cture. HPE
HPE Smart Array P-series controllers. The following operating systems are supported by the HPE
Page 5
QuickSpecs
HPE Smart Array P721m Controller
Standard Features
Page 5
Microsoft Windows 2008 Server
Microsoft Windows 2008 R2 Server
Microsoft Windows 2012 Server
Page 6
QuickSpecs
HPE Smart Array P721m Controller
Compatib
ility
Page 6
Supported Servers
HPE ProLiant BL420c Gen8
HPE ProLiant BL460c Gen8
HPE ProLiant BL465c Gen8
HPE ProLiant BL660c Gen8
NOTE:
NOTE:
QuickSpecs
http://h71069.www7.hp.com/quickspecs/overview.html
Operating Systems and Virtualization Software Support for ProLiant Servers
Microsoft Windows Server 2008 with SP2
Microsoft Windows Server 2012
Microsoft Windows Server 2008 R2 with SP1
Microsoft Windows Small Business Server 2011
SLES 10 SP4
SLES 11 SP1
Red Hat Enterprise Linux 5
VMware ESX/ESXi 4.1
VMware ESXi 5.0
NOTE: For more information on Hewlett Packard Enterprise Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at:
http://www8.hp.com/us/en/products/servers/management/operating support-matrix.html
Software Suite
Most current shipping Smart Array products share a common set of configuration, management and diagnostic tools, including software consistency of tools reduces the cost of training for each successive generation of product and takes much of the ownership by reducing training and technical expertise necessary to install and maintain storage.
HPE Systems Insight Manager
Powerful server and server options/storage manager tool
HPE SmartStorage Administrator
Comprehensive management for HPE Smart Storage products
For more information please visit: http://www.hp.com/go/hpssa
HPE Storage
Initial System Configuration Wizard is the easiest and simplest
For BL420c Gen8 & BL460c Gen8 - P721m is a Type B mezzanine .It can only be installed
on mezzanine slot 2 which requires a second processor for functionality. The BL420c, BL465c, and BL460c Gen8 can only support one Type B mezzanine.
For BL465 Gen8 - P721m is a Type B mezzanine and can only be installed on mezzanine
slot 2
For BL660c Gen8 - P721m is a Type B mezzanine. It can only be supported on mezzanine
slot 2 and mezzanine slot 3. The BL660c Gen8 can support up to two Type B mezzanines.
For more information on internal vs. external connections, please refer to proper blade
please visit:
-environments/os-
HPE SmartStorage Administrator and HPE Systems Insight Manager. This
guesswork out of troubleshooting field problems. These tools lower the total cost of
HPE server
Monitors over 1200 system wide parameters
Configuration/Diagnostic Utilities
(HPE SSA)
Simplified and intuitive interface and functionality
Advanced scripting and diagnostic features
Page 7
QuickSpecs
HPE Smart Array P721m Controller
Compatibility
Page 7
Management Utility
method for configuring the storage system initially.
Command Line Interface (CLI) for command level method of
configuring and managing the storage
Main User Interface for multi-server environments that need
customization for creation of storage Luns and targets.
P2000 G3 Arrays can be configured using Storage Management
Utility (SMU) or Command Line Interface (CLI) both of which are embedded in the P2000 G3 Array controller firmware.
Page 8
QuickSpecs
HPE Smart Array P721m Controller

Service and Support

Page 8
Service and Support
HPE Technology Services
Capitalizing on understands your increasingly complex business technology environment. That's why it makes sense to team up with the people who know best - the experienced professionals at HPE Services.
Protect your business beyond warranty with HPE Pointnext operational services When you buy HPE Pointn choices designed to meet your IT and business need.
HPE
Hewlett Packard Enterprise
servers
software. You can choose the type and level of service that is most suitable for your IT and
business needs.
Proactive Care delivers high levels of system availability through proactive service
management and advanced technical response.
Recommended HPE Pointnext operational services for optimal satisfaction with your HPE product
Optimized
3-Year HPE 6 hour Call to Repair Response, Proactive Care
Combined reactive and proactive support for hardware and software helping optimize your systems a delivering high levels of availability through proactive service management and advanced technical response. Hardware problem resolution to return the hardware in operating condition within 6 hours of the initial service request. A Technical Account Man resolved.
https://www.hpe.com/h20195/v2/GetPDF.aspx/4AA3
HPE
This easy hardware operations.
Standard Care
3-Year HPE 24x7 4 hour Response, Proactive Care
This service gives you combined reactive and proactive support including rapid access to our Advanced Solution Center to manage and prevent problems and a Technical Support Specialist with a br knowledge that will engage with additional technical expertise as needed from global resources.
https://www.hpe.com/h20195/v2/Ge
HPE
This easy hardware operations.
Related Services
HPE Proactive Care Personalized Support - Environmental Option
the industry plus extra technical skills to your IT team. This option is only available
as an add-on to HPE Proactive Care Support.
HPE Proactive Select Service
https://www.hpe.com/h20195/V2/GetPDF.aspx/4AA2-3842ENN.pdf
Insight Online/Insight
HPE Insight Remote Support provides 24 X 7 remote monitoring, proactive notifications, and problem
HPE ProLiant server and HPE BladeSystem capabilities requires a service partner who
Hewlett Packard Enterprise infrastructure hardware and software
HPE Options, it's also a good time to think about what level of service you may need.
ext operational services provide total care and support expertise with committed response
Foundation Care services offer scalable reactive support-packages for
and
HPE
Care
nd
ager, as your single point of contact, will own your call or issue end to end until
-8855EEE.pdf
Installation of ProLiant Add On Options Service
-to-buy, easy-to-use HPE Care Pack service helps ensure that your new Hewlett Packard Enterprise or software is installed smoothly, efficiently, and with minimal disruption of your IT and business
oad level of technical
Hewlett Packard Enterprise vast
tPDF.aspx/4AA3-8855EEE.pdf
Installation of ProLiant Add On Options Service
-to-buy, easy-to-use HPE Care Pack service helps ensure that your new Hewlett Packard Enterprise or software is installed smoothly, efficiently, and with minimal disruption of your IT and business
The Personalized Support option provides an assigned Account Support Manager who can bring best practices from across
Provides a flexible way to purchase HPE best-in-class consultancy and technical services. You can buy Proactive Select Service Credits when you purchase your hardware and then use the credits over the next 12 months.
Page 9
QuickSpecs
HPE Smart Array P721m Controller
Service and Support, HPE Care Pack, and Warranty Information
Page 9
Remote Support
resolution. This comes at no additional cost with your HPE solution. Learn more about Insight Remote
HPE Support Center
Personalized online support portal with access to information, tools and experts to support Hewlett
NOTE: *The HPE Support Center Mobile App is subject to local availability
Parts and materials
Hewlett Packard Enterprise will provide HPE-supported replacement parts and materials necessary to
Parts and components that have reached their maximum supported lifetime and/or the maximum usage
replaced by HPE due to malfunction.
For more information
To learn more on HPE BladeSystem services, please contact your Hewlett Packard Enterprise sales
http://www.hp.com/services/bladesystem
Warranty
The warranty for this device is 3 years parts only.
http://www.hp.com/services
Support http://www.hp.com/go/insightremotesupport and Insight Online
http://h18013.www1.hp.com/products/servers/management/insight-online/index.html
Packard Enterprise business products. Submit support cases online, chat with HPE experts, access support resources or collaborate with peers. Learn more
The HPE Support Center Mobile App* allows you to resolve issues yourself or quickly connect to an agent for live support. Now, you can get access to personalized IT support anywhere, anytime. HPE Insight Remote Support and HPE Support Center are available at no additional cost with a HPE warranty, HPE Care Pack or Hewlett Packard Enterprise contractual support agreement.
maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements.
limitations as set forth in the manufacturer's operating manual, product QuickSpecs, or the technical product data sheet will not be provided, repaired, or replaced as part of these services.
The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives
http://www.hp.com/go/hpsc
representative or Hewlett Packard Enterprise Authorized ServiceOne Channel Partner. Or visit:
.
Pre-Failure Warranty: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HPE Support Center or refer to your HPE Server Documentation.
Enhancements to warranty services are available through Care Pack services.
NOTE: For more information, visit HPE Pointnext operational services at:
Page 10
QuickSpecs
HPE Smart Array P721m Controller

Related Options

Page 10
HPE Hard Drives
NOTE: Please see supported HPE Disk Enclosure QuickSpecs for a list of
compatible hard drives.
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04111505
(
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04111697
(
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04140213
(HPE MDS600)
HPE SAS Switches
HPE 6Gb SAS Switch Single Pack for HPE BladeSystem c-Class
BK763A
HPE 6Gb SAS Switch Dual Pack for HPE BladeSystem c-Class
BK764A
NOTE: Please see the QuickSpecs for Technical Specifications and additional information at:
https://www.hp
NOTE:
or greater to enable support for P721m.
HPE c Class Blade Enclosures
HP BLc7000 Enclosure with 1 Phase 2 Power Supply 4 Fan ROHS ICE License
507014-B21
HP BLc7000 Enclosure with 1 Phase 6 Power Supply 10 Fan FI ROHS ICE License
507015-B21
HP BLc7000 Enclosure with 3 Phase 6 Power Supply 10 Fan INTL ROHS ICE License
507016-B21
HP BLc7000 Enclosure with 3 Phase 6 Power Supply 10 Fan ENG ROHS ICE License
507017-B21
HPE BLc3000 Platinum Enclosure with 4 AC Power Supplies 6 Fans ROHS 8 Insight Control Licenses
696908-B21
HPE BLc3000 Platinum Enclosure with 4 AC Power Supplies 6 Fans ROHS Trial Insight Control License
696909-B21
HP BLc3000 Enclosure with 4 AC Power Supplies 6 Fan Full ICE License
508664-B21
HP BLc3000 Enclosure with 4 AC Power Supplies 6 Fan Trial ICE License
508665-B21
HP BLc3000 Enclosure with 2 AC Power Supplies 4 Fan Trial ICE License
536841-B21
HPE Disk Enclosures
Disk Enclosures
HPE D2000 Disk Enclosures
HP D2600 Disk Enclosure
NOTE: Supports 12 LFF drives, and SAS 6Gb/s and SATA 3Gb/s.
AJ940A
HPE D2700 Disk Enclosure
NOTE: Supports 25 SFF drives, and SAS 6Gb/s and SATA 3Gb/s.
AJ941A
NOTE: Please see the supported Disk Enclosure QuickSpecs for a list of compatible hard drives:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04111697
(HPE D2000 Disk Enclosure)
HPE D6000 Dual I/O Module Disk Enclosure NOTE:NOTE: Please see the supported Disk Enclosure QuickSpecs for a list of compatible hard drives: https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04111505 (HPE D6000 Disk Enclosure)
QQ695A
HPE MSA 2040 Storage
HP MSA 2040 SAS Dual Controller LFF Storage
C8S54A
HP MSA 2040 SAS Dual Controller SFF Storage
C8S55A
NOTE: Please see the supported MSA QuickSpecs for a list of compatible hard drives: https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04123144
HPE D6000 Disk Enclosure)
HPE D2600 and D2700 Disk Enclosure)
e.com/h20195/v2/GetHTML.aspx?docname=c04123176
Please note that the 6Gb SAS switch should have firmware version 3.0.8.0
Page 11
QuickSpecs
HPE Smart Array P721m Controller
Related Options
Page 11
HPE P2000 G3 Modular Smart Array Systems
P2000 G3 SAS Controller
HP P2000 G3 SAS MSA Array System Controller
AW592B
P2000 Chassis
P2000 Controller-less Chassis (AC-powered)
HP P2000 LFF Modular Smart Array Chassis
NOTE: Will accept one or two controllers or Disk Enclosure I/O modules.
AP838B
HP P2000 SFF Modular Smart Array Chassis
NOTE: Will accept one or two controllers, not I/O modules.
AP839B
Configured Units, 6 Gb SAS Systems
HP P2000 G3 SAS MSA Dual Controller LFF Array System
AW593B
HP P2000 G3 SAS MSA Dual Controller SFF Array System
AW594B
Disk Enclosures
HP P2000 Dual I/O LFF Drive Enclosure
AP843B
HPE P2000 LFF Drive Enclosure I/O Module
NOTE:
AP838A to create a single I/O JBOD.
AJ844B
HPE D2700 SFF Disk Enclosure, twenty-five 2.5" drive bays
NOTE:
controller LFF or SFF array head.
AJ941B
HPE Tape Backup
Tape Autoloaders
HPE StoreEver 1/8G2 LTO-6 Ultrium 6250 SAS Tape Autoloader
COH18A
HPE StoreEver 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader
AK377B
HPE StoreEver 1/8 G2 LTO-5 Ultrium 3000 SAS Tape Autoloader
BL536B
Tape Libraries
HPE StoreEver MSL2024 1 LTO-6 Ultrium 6250 SAS Tape Library
COH20A
HPE StoreEver MSL2024 2 LTO-6 Ultrium 6250 SAS Tape Library
COH21A
HP MSL2024 1 LTO-4 Ultrium 1760 SAS Tape Library
AK378B
HPE StoreEver MSL4048 2 LTO-6 Ultrium 6250 SAS Tape Library
COH23A
HP MSL4048 2 LTO-4 Ultrium 1760 SAS Tape Library
AK380B
HPE StoreEver MSL4048 0-drive Tape Library
AK381A
HPE StoreEver MSL8096 2 LTO-6 Ultrium 6250 SAS Tape Library
COH25A
No cable included. Designed exclusively for use with the LFF chassis
With two .5m mini-SAS to mini-SAS cables. Used with single or dual
Page 12
QuickSpecs
HPE Smart Array P721m Controller

Technical Specifications

Page 12
Disk Drive and Enclosure Protocol Support
SAS protocol: 6Gb/s, 3Gb/s
SATA protocol: 6Gb/s,3Gb/s
SAS Connectors
4 external 2x ports to support up to 4 6Gb/s SAS Switches
SAS Port Link Rate
6Gb/s per physical link
Memory Bus Speed
DDR3-1333MHz and 40-bit wide bus (512MB cache module) or 72-bit wide bus (2GB cache module)
Physical Drives Supported
Up to 227 zoned physical drives
Logical Drives Supported
64 logical drives
Maximum Capacity
Variable depending upon enclosure
Memory Addressing
64-bit, supporting servers memory space greater than 4 GiB (4.4 GB)
RAID Support
RAID 6, 60 (Advanced Data Guarding) RAID 5, 50 (Distributed Data Guarding) RAID 1, 10 (Drive Mirroring) RAID 1 ADM, 10 ADM (Advanced Data Mirroring) RAID 0 (Striping)
Upgradeable Firmware
Flashable ROM with redundant firmware images
Environment-friendly Products and Approach
End-of-life Management and Recycling
Hewlett Packard Enterprise offers end-of-life product return, trade-in, and recycling programs, in many geographic areas, returned to Hewlett Packard Enterprise will be recycled, recovered or disposed of in a responsible manner.
http://www8.hp.com/us/en/hpe/hp information/livingprogress/environmentalprogress/product recycling.html#.V
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by This information (product disassembly instructions) is posted on the Hewlett Packard Enterprise web site. These instructions may be used by recyclers and other WEEE treatment facilities as well as HPE OEM customers who integrate and
sell Hewlett Packard Enterprise equipment.
http://www8.hp.com/us/en/hpe/hp information/livingprogress/environmentalpr recycling.html#.V-lPA_krKiM
-
-lPA_krKiM
re-
-
for our products. Products
-
treatment facilities.
ogress/product-
Page 13
QuickSpecs
HPE Smart Array P721m Controller

Summary of Changes

Page 13
Date
Version History
Action
Description of Change
23-Oct-2017
Version 11
Added
Care Pack naming and Service and Support- Parts and Materials updated.
07-Oct-2016
From Version 9 to 10
Changed
QuickSpecs was rebranded.
18-Apr-2014
From Version 8 to 9
Changed
Models and Related Options were revised.
08-Nov-2013
From Version 7 to 8
Added
HPE MSA 2040 Storage was added to HPE Disk Enclosures.
10-Sep-2013
From Version 6 to 7
Changed
Standard Features, Service and Support, HPE Care Pack,
Specifications were revised.
10-Jun-2013
From Version 5 to 6
Changed
Overview: Updated Whats New with: Up to 4x better Solid
Related Options: Updated HPE SAS Switches section.
Added
Standard Features: Added SP Smart Cache and HPE SSD Smart Path sections.
25-Feb-2013
From Version 4 to 5
Changed
Overview Section: Updated What's New and product
Array Systems
Added
Overview Section: Added D6000 and MDS600
Support for ProLiant Servers.
03-Oct-2012
From Version 3 to 4
Changed
Changes were made in Overview, Standard Features and Technical Specifications sections.
28-Sep-2012
From Version 2 to 3
Changed
Changes were made in Overview, Standard Features and Technical Specifications sections.
17-Aug-2012
From Version 1 to 2
Changed
Changes were made in Overview, Standard Features and Technical Specifications sections.
and Warranty Information, Related Options, and Technical
State Disk (SSD) read performance with the SSD Smart Path firmware and driver based feature for Smart Array controllers.
Standard Features: Updated Key features section
descriptions in Models.
Standard Features Section: Updated RAID Controller Features in Key Features.
Compatibility Section: Updated NOTE in Supported Servers
Related Options Section: Completely updated HPE Hard Drives, HPE SAS Switches, HPE c Class Blade Enclosures, HPE Disk Enclosures and HPE P2000 G# Modular Smart
Compatibility Section: Added Microsoft Windows Server 2012 to Operating Systems and Virtualization Software
Page 14
QuickSpecs
HPE Smart Array P721m Controller
Summary of Changes
14
Sign up for updates
© Copyright 2017 Hewlett Packard Enterprise Development LP. The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Ent services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical
Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries.
C04111449
erprise products and
or editorial errors or omissions contained herein.
- 14404 - Worldwide - V11 - 23-October-2017
Page
Loading...