Intended audience
This document is for the person who installs racks and rack products. This procedure is performed only by
trained personnel. HP assumes you are qualified in performing installations and trained in recognizing
hazards in rack products.

Contents
Configuration factors ..................................................................................................................... 5
Rack configuration software ........................................................................................................................ 5
HP eCo-Enterprise Configurator ......................................................................................................... 5
Optimum environment ................................................................................................................................ 5
Space requirements ......................................................................................................................... 5
Power requirements ......................................................................................................................... 6
Temperature requirements ................................................................................................................. 6
Airflow requirements ........................................................................................................................ 6
Populating your new rack ........................................................................................................................... 6
Additional rack considerations .................................................................................................................... 7
General component placement guidelines .................................................................................................... 8
Preparing the rack for component installation ................................................................................. 10
Checking the hardware ............................................................................................................................ 10
Hardware kit contents .................................................................................................................... 10
Required tools ............................................................................................................................... 11
Removing the rack doors .......................................................................................................................... 11
Removing the front door ................................................................................................................. 11
Removing the rear doors ................................................................................................................ 13
Removing the side panels ......................................................................................................................... 13
Stabilizing requirements ........................................................................................................................... 15
Rack stabilizer option kit................................................................................................................. 16
Rack baying option kit ................................................................................................................... 17
Rack tie-down option kit ................................................................................................................. 17
Installing components .................................................................................................................. 19
Installing components ............................................................................................................................... 19
Installing the cage nuts ............................................................................................................................. 19
Installing the hook-and-loop components ..................................................................................................... 21
Installing the cable management brackets ................................................................................................... 22
Rack options .............................................................................................................................. 23
Ordering rack options .............................................................................................................................. 23
Specifications ............................................................................................................................. 25
HP G2 rack specifications ........................................................................................................................ 25
HP 10622 G2 Rack specifications ............................................................................................................. 25
HP 10636 G2 Rack specifications ............................................................................................................. 25
HP 10642 G2 Rack specifications ............................................................................................................. 25
HP 10647 G2 Rack specifications ............................................................................................................. 25
HP 10642 1200 mm Full Frame Rack specifications .................................................................................... 25
HP 10647 1200 mm Full Frame Rack specifications .................................................................................... 26
HP 10842 G2 Rack specifications ............................................................................................................. 26
HP 10642 Extended Depth Rack specifications ........................................................................................... 26
HP 10647 Extended Depth Rack specifications ........................................................................................... 26
Electrostatic discharge ................................................................................................................. 27
Preventing electrostatic discharge .............................................................................................................. 27

Grounding methods to prevent electrostatic discharge .................................................................................. 27
Technical support ........................................................................................................................ 28
Before you contact HP .............................................................................................................................. 28
HP contact information ............................................................................................................................. 28
Acronyms and abbreviations ........................................................................................................ 29
Index ......................................................................................................................................... 30

Configuration factors
Rack configuration software
To help you plan your rack configuration more efficiently, HP provides eCo-Enterprise Configurator, a
powerful web-based service that enables you to build, store, and export end-to-end rack configurations.
HP strongly recommends that you configure the rack using the eCo-Enterprise Configurator, which
provides factory default racking. The latest version of the software is available on the HP website
HP eCo-Enterprise Configurator
(http://h30099.www3.hp.com/eGlue/eco/begin.do
HP Custom Builder was retired from service on 12 December 2005.
If you require factory default racking for the HP hardware portfolio, you can still use the HP eCo-Enterprise
Configurator, which is available on the HP website
(http://h30099.www3.hp.com/eGlue/eco/begin.do
).
).
If you require custom rack configuration capabilities, contact the HP Customer Business Center or an HP
authorized partner for assistance.
The HP eCo-Enterprise Configurator now provides factory default racking for HP hardware. This approach
is aligned with the strategic direction to meet the needs and expectations of valued customers. If you
require a custom rack configuration, contact the HP Customer Business Center or an authorized partner
for assistance.
Optimum environment
Specific requirements for space, power, temperature, and airflow must be met to provide optimum
performance with minimum maintenance for your rack environment.
For additional information, refer to the Best Practices document on the HP website
Space requirements
(http://h18004.www1.hp.com/products/servers/proliantstorage/racks
When deciding where to place your rack:
• At least 1219 mm (48 in) of clearance is needed all the way around the pallet and above the rack
to enable the removal of the packing material.
• At least 1219 mm (48 in) of clearance is needed in front of the rack to enable the door to open
completely.
).
• At least 762 mm (30 in) of clearance is needed in the rear of the rack to provide access to
components.
• At least 380 mm (15 in) of clearance is needed around a power supply to facilitate servicing.
Configuration factors 5