Honeywell W8600F User Manual

APPLICATION

LCD
N
W8600F Air Cleaner Monitor
INSTALLATION INSTRUCTIONS
The W8600F AirCleaner Monitor isan option available for use with theF50F and F52F Honeywell Electronic Air Cleaners (EAC). The series two F50F and F52F require a solid state power supply that is compatible with the W8600F driver board. Any series one F50E, F or F52F can be upgraded to use the W8600F when the power supply is replaced and the driver board (included in W8600F kit) is installed.
The W8600F function indicator panel has four liquid crystal display (LCD) arrowheads that point to ON, BATTERY,SERVICE or FAULT. See Fig. 1. The arrowheads darken to indicate the existing EAC condition. See Table 1.

INSTALLATION

When Installing this Product..
1. Read these instructions carefully. Failure to follow the instructions could damage the product or cause a hazardous condition.
2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application
3. Installer must be a trained, experienced service technician.
4. After completing the installation, use these instruc­tions to check out the product operation.
Location
The styling of the W8600F is designed to blend with the latest T8600 family of Honeywell Chronotherm¨ IV Deluxe Programmable Thermostats. A special mounting template is included for mounting next to the T8600. The W8600F can also be mounted at any other convenient location in the living area or equipment room. See Fig. 2.
NOTE: The W8600Fshares no common electricalcon-
nections with the thermostat.
ON BATTERY SERVICE
FAULT
Air Cleaner Monitor
FUNCTION INDICATOR PANEL
RESET BUTTO
M11965
Fig. 1. W8600F Air Cleaner Monitor features.
Table 1. Description of W8600F Function Indicator
Panel.
Indicators Condition
ON EAC ispowered and systemblower is
BATTERY Battery thatmaintains W8600F
SERVICE EAC prefilter and cells need to be
FAULT •Shortingof collectorplates.
running.
memory is low and needs to be replaced.
a
.
washed
•Continuous ionizer or collector plate arcing.
•Power supply failure.
•Excessive current.
•Major reduction in high voltage.
•EAC prefilter and cells are past SERVICE level of dirt and need to be washed immediately. Call a service technician.
a
The reset button is located on the bottom of W8600F. After the prefilters and cells are cleaned and reinstalled, press this button to turn off the SERVICE indicator and reset the wash frequency timer.
® U.S. Registered Trademark Copyright © 2002 Honeywell International Inc. • • All Rights Reserved
69-1200-2
W8600F AIR CLEANER MONITOR
F
MOUNTING HOLES (2)
EAC
F52-ATTIC
On
Battery Service Fault
Air Cleaner Monitor
EAC
RETURN AIR DUCT
W8600F
W8600F
EAC
CLOSET
Fig. 2. W8600F mounting locations.
W8600F
W8600F
EAC
CEMENT BLOCK WALL
W8600
EAC
GARAGE/DRYWALL
M11966

Mounting

The following mounting instructions assume that the W8600F is mounted next to a T8600 Thermostat. If installing the monitor at another location, modify the procedure to fit the installation.
1. Hold the mounting template (included in the W8600F kit) next to the T8600 as shown in Fig. 3.
2. Mark the holes for the screw anchors and the 3-conductor thermostat cable.
3. Remove the template and drill the holes.
4. Remove the W8600F from the base.
5. Position the W8600F base over the holes and
install the anchors and screws (included in the bag assembly). Tighten the screws until the base is mounted firmly on the wall.
69-1200—2 2
THERMOSTAT WALLPLATE
Fig. 3. Positioningmounting template.
MOUNTING TEMPLATE
WIRING HOLE
M11971