APPLICATION
W8600A AIR
WATCH™
INSTALLATION INSTRUCTIONS
Indicator
The W8600A is available for use with Honeywell media
or electronic air cleaners.
The W8600A function indicator panel has four liquid
crystal display (LCD) arrowheads that point to Battery, Air
Cleaner, UV Air Treatment, and Humidifier. (See Fig. 1.)
A blinking arrowhead indicates service is needed.
LCD
FUNCTION
INDICATOR
PANEL
RESET BUTTON
M14696
Indicator features.
Battery
Air Cleaner
UV Air Treatment
Humidifier
Honeywell.com/yourhome
Fig. 1. W8600A AIR
TM
WATCH™
INSTALLATION
Location
The W8600A is designed to blend with the latest T8600
family of Honeywell Chronotherm® IV Thermostats. The
W8600A can also be mounted at any other convenient
location in the living area of the home. See Fig. 2.
A
M
S
y
s
t
e
m
H
e
a
Tue
Wake
t
Room
F
a
n
DST
A
u
t
o
T
M
Battery
Air Cleaner
UV Air Treatment
Humidifier
H
o
n
e
y
w
e
ll.c
o
m
/y
o
u
r
h
o
m
e
M14697
Fig. 2. W8600A mounting location.
Mounting
These mounting instructions assume that the W8600A is
mounted next to a T8600 Thermostat. When installing at
another location, modify the procedure to fit the
installation:
Remove the W8600A from the base.
1.
Mark the holes for the mounting screws (provided)
2.
using the base as a template. See Fig. 3.
Drill the holes.
3.
Position the base over the holes and install the
4.
screws.
Tighten the screws until the base is mounted firmly
5.
on the wall.
Replace the W8600A onto the base.
6.
THERMOSTAT
WALLPLATE
MOUNTING HOLES (2)
Fig. 3. Using base as mounting template.
W6800A BASE
WIRING HOLE
M14695
® U.S. Registered Trademark
Copyright © 2000 Honeywell • • All Rights Reserved
69- 1448
W8600A AIRWATCH™ INDICATOR
Set DIP Switches
Set the DIP switches according to equipment
1.
installed in the home:
a. Use default position set at the factory when all
devices (air cleaner, UV air treatment system,
humidifier) are installed in the home.
b. Move DIP switch to left (off position) when a
device is not installed in the home.
NOTE: The UV air treatment system and the
humidifier settings are for one year. The
air cleaner settings are selectable according to homeowner activities and needs.
Determine the air cleaner filter run time you desire
2.
and set the DIP switches accordingly:
a. If air cleaner filter is used, select desired filter
time of 3, 6, 9 or 12 months. Follow the settings
on the back of the W8600A to set the DIP
switches for the desired number of months.
b. If air cleaner filter is not used, move the filter
time DIP switches 4 and 5 to the left (off).
c. Use factory default settings to change the
media filter or wash the electronic filter every
three months.
Install Batteries
Remove the back cover by pressing in on the tab
1.
on the bottom edge (top is hinged).
Install two AAA alkaline batteries (provided), in the
2.
harness on the back of the unit.
Observe that the W8600A performs a self-test,
3.
beeping and flashing the LCD display individually
for each device (air cleaner, UV air treatment system, humidifier) installed in the home.
Press and hold the black reset button on the bot-
4.
tom of the device for five seconds or until the display stops flashing to start the timers.
Observe Battery LCD:
5.
a. On solidly means unit is correctly powered.
b. Flashing indicates battery requires replacing.
SERVICE
The unit beeps every fifteen minutes to indicate an LCD
is flashing. This means that service or a replacement part
is required.
Replace or service the part corresponding with the
1.
LCD flashing.
Replace the batteries within 30 seconds of removal
2.
to maintain the correct indication time.
Within 30 seconds after replacing the batteries, if
3.
the LCD is blank, remove and install new batteries.
Press and hold the black button on the bottom of
4.
the device to reset the timer after servicing or
replacing parts.
TROUBLESHOOTING
If arrow is
LCD
Battery Batteries need
Air Cleaner Media filter needs
UV Air
Treatment
Humidifier Humidifier pad
flashing or unit
is beeping... Reset by...
changing.
replacing or
electronic filter
needs washing.
UV lamps need
replacing in UV air
treatment system.
needs replacing.
Changing batteries
within 30 seconds of
removing old batteries
to maintain correct
indication time.
Pressing and holding
reset button for 10
seconds or until arrow
is no longer displayed.
Pressing and holding
reset button for 10
seconds or until arrow
is no longer displayed.
Pressing and holding
reset button for 10
seconds or until arrow
is no longer displayed.
Home and Building Control Home and Building Control
Honeywell Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North 35 Dynamic Drive
Golden Valley, MN 55422 Scarborough, Ontario
69-1448 G.H. 9-00 www.honeywell.com/your home/
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.