Honeywell TB-WALL, TR20 Series Catalog Page

Temperature Sensors
TB-WALL 10K ohm NTC Type II Temperature Sensors
Honeywell 10K ohm NTC Type II remote wall sensors are for use with the TB7200, TB7300, and TB7600 Series communicating thermostats and other devices requiring a 10K ohm NTC Type II sensor. These robust sensors provide accurate and stable temperature readings using a 10K ohm NTC thermistor element. The TB-WALL sensors can also be used for temperature averaging applications.Two or three TB wall sensors can be used and are quickly configured with the onboard dip switches. Temperature averaging with the usual 4, 9, 16, 25, etc. sensors can also be done with the TB wall sensors.
Dimensions, Approximate: 5 in. high x 3 3/8 in. wide x 1 3 5/32 in.
deep (125 mm high x 86 mm wide x 29 mm deep)
Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Shipping Temperature Range: -22 F to +122 F (-30 F to +50 F)
Product Number Application Sensor Type Description
TB-WALL-1014/U Wall temperature sensor 10 K ohm NTC @ 77 F Type II Wall Sensor
TB-WALLOVR-1014/U Wall temperature sensor with override 10 K ohm NTC @ 77 F Type II Wall Sensor with Override
Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Mounting: Wall mount Used With: TB7600, TB7300, TB7200 Series communicating
thermostats
TR20 Series Wall Modules
The TR21, TR22, TR23, TR24, and TR29 are a family of direct wired wall modules for use with Honeywell Excel 600, 500, 100, and 80 controllers; Excel 10 W7750, W7751A, W7752, and W7753 controllers; W7761 Controller; and Spyder Unitary Controllers. All models have a space temperature sensor.
• Models available with user selectable setpoint adjustment dials in Fahrenheit, Celsius and Relative Scales
• Models available with occupied/unoccupied override (bypass) with LED
• Models available with 3-position (auto/0/1) or 5-position (auto/0/1/2/3 speed) fan switch
• LONWORKS network jack on all models except the TR21 and TR21­A models
• Models available with on board humidity sensor, humidity output: 0­10Vdc, 0-5 Vdc, 4-20ma selectable
• Sensor can be mounted inside of the enclosure or directly to the wall or duct using the mounting clips supplied with the unit.
Commercial
Components
Application: Networked Sensor Application Type: Wall Module Dimensions, Approximate: 4 13/16 in. high x 3 in. wide x 7/8 in. deep
(122mm high x 76.5 mm wide x 22 mm deep)
Color: White Operating Temperature Range: 45 F to 99 F (7 C to 37 C) Setpoint Temperature Range: 55 F to 85 F (13 C to 30 C) Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C) Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Switch Positions (Fan) Comments Includes
Also used with the T7350 and
Special 10K ohm for use only
Also used with T7350
LON Jack
Also used with T7350
70-6910 473
Product Number Application
TR21/U Networked
TR21-A/U For use only
TR21-H/U Networked
TR21-J/U Networked
TR22/U Networked
Sensor
when averaging multiple sensors
Sensor
Sensor
Sensor
Network Jack Sensor Type
None 20 K ohm NTC
None Unique 10K ohm
LonWorks Bus
LonWorks Bus
LonWorks Bus
non-linear
non-linear, two 20Ks in parallel
20 K ohm NTC non-linear
20 K ohm NTC non-linear
20 K ohm NTC non-linear
Mounting: Mounted on a standard 2 x 4 inch junction box or on a 60
mm diameter junction box.
Comments: Also used with the T7350 and TB8220 Thermostats Used With: Spyder, Excel 600, 500, 100, 80 and Excel 10, 15 Series
Controllers
Approvals CE: Approved Federal Communications Commission: FCC Part 15, Class B Underwriters Laboratories, Inc: UL94 plastic enclosure
TB8220 Thermostats
when averaging multiple sensors, can also be used with T7350, TB8220 Thermostats
Thermostat
Thermostat
Humidity and LON Jack
Selectable Setpoint dials in Fahrenheit, Celsius, and Relative (- to +) and LON Jack
Loading...