Honeywell T991A Catalog Page

Temperature Controllers
M23881
BULB LENGTH IS 3-9/16 (91).ON 55 TO 175 F AND 15 TO 75 C RANGE.
1
1
KNOCKOUT FOR 1/2-INCH CONDUIT (2)
4-3/16
(106)
2
(51)
1/2
(13)
3/8
(10)
1-3/16
(51)
17/32
(13)
4-3/16
(106)
5-5/8 (143)
2-1/4
(57)
2-1/8
(54)
15/16 (24)
7/32 DIA.
(3)
T991A Proportional Temperature Controller
Proportional (135 ohm) remote bulb controllers for modulating control of water or air temperature in ducts, tanks and similar applications.
• Fast response models (for duct mounting) have coiled sensing element giving at least four times faster response than standard models
• Ambient temperature compensated for the case and tubing
• Setpoint may be read and adjusted through cover
• Throttling dial inside case adjusts proportional throttling range
Dimensions in inches (millimeters) Type: Modulating Remote bulb
Application: Provide modulating control of water or air temperature
in ducts or tanks
Color: Gray Voltag e: 24 Vac to 30 Vac Frequency: 50 Hz; 60 Hz Output Type: Analog Number of Sensor Inputs: 1
Setpoint Temperature
Product Number
T991A1004/U
T991A1012/U
T991A1061/U
T991A1079/U
T991A1095/U
T991A1186/U
T991A1194/U
T991A1210/U
T991A1244/U
T991A1269/U
T991A1343/U
358 customer.honeywell.com 70-6910
Range
(F) (C) (F) (C) (F) (C) (inch) (mm) (ft) (m)
0 F to 100 F
0 F to 100 F
160 F to 260 F
160 F to 260 F
5 F to 95 F
55 F to 175 F
55 F to 175 F
59 F to 167F
55 F to 175 F
55 F to 175 F
55 F to 175 F
Maximum Operating Tem per atu re
-18 C to
125 F 52 C 3 F to
+38 C
-18 C to
125 F 52 C 3 F to
+38 C
71 C to
280 F 138 C 3 F to
127 C
71 C to
280 F 138 C 3 F to
127 C
-15 C to
125 F 52 C 3 F to
+35 C
13 C to
200 F 93 C 3 F to
79 C
13 C to
200 F 93 C 3 5 F to
79 C
15 C to
200 F 93 C 3 F to
75 C
13 C to
200 F 93 C 3 5 F to
79 C
13 C to
200 F 93 C 3 5 F to
79 C
13 C to
200 F 93 C 3 5 F to
79 C
Throttling Range Bulb Size
1.7 C to
16.7 C
1.7 C to
16.7 C
1.7 C to
16.7 C
1.7 C to
16.7 C
1.7 C to
16.7 C
1.7 C to
16.7 C
1 9 C to 20 C
1.7 C to
16.7 C
1 9 C to 20 C
1 9 C to 20 C
1 9 C to 20 C
1/2 in. diameter x 4 3/16 in. long
1/2 in. diameter x 4 3/16 in. long
1/2 in. diameter x 4 3/16 in. long
1/2 in. diameter x 4 3/16 in. long
1/2 in. diameter x 4 3/16 in. long
1/2 in. diameter x 4 3/16 in. long
1/2 in. diameter x 3 9/16 in. long
1/2 in. diameter x 4 3/16 in. long
1/2 in. diameter x 3 9/16 in. long
1/2 in. diameter x 3 9/16 in. long
1/2 in. diameter x 3 9/16 in. long
30 F
30 F
30 F
30 F
30 F
30 F
36 F
10 F
36 F
36 F
36 F
13 mm diameter x 107 mm long
13 mm diameter x 107 mm long
13 mm diameter x 107 mm long
13 mm diameter x 107 mm long
13 mm diameter x 107 mm long
13 mm diameter x 107 mm long
13 mm diameter x 90 mm long
13 mm diameter x 107 mm long
13 mm diameter x 90 mm long
13 mm diameter x 90 mm long
13 mm diameter x 90 mm long
Capillary Length
5 ft 1.5 m One 135 Ohm
20 ft 6.1 m One 135 Ohm
5 ft 1.5 m One 135 Ohm
20 ft 6.1 m One 135 Ohm
5 ft 1.5 m One 135 Ohm
5 ft 1.5m One 135 Ohm
20 ft 6.1m One 135 Ohm
5 ft 1.5m One 135 Ohm
5 ft 1.5m One 135 Ohm
20 ft 6.1m One 280 Ohm
5 ft 1.5m One 280 Ohm
Analog Output Sensor Element Includes
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Copper bulb
Copper bulb
Copper bulb
Copper bulb
Copper bulb Celsius scale
Copper bulb
Copper bulb
Copper bulb Celsius Scale
Copper bulb 107324A Duct
Copper bulb
Copper bulb 107324A Duct
Bulb holder
Bulb holder
Temperature Controllers
131524A
M17276A
Product Number
T991A1350/U
T991A1426/U
T991A1715/U
T991A1756/U
T991A1764/U
T991A2069/U
Setpoint Temperature Range
(F) (C) (F) (C) (F) (C) (inch) (mm) (ft) (m)
55 F to 175 F
0 F to 100 F
0 F to 100 F
55 F to 175 F
0 F to 100 F
0 F to 100 F
Maximum Operating Temperature
13 C to
200 F 93 C 3 5 F to
79 C
-18 C to
125 F 52 C 3 F to
+38 C
-18 C to
125 F 52 C 3 F to
+38 C
13 C to
200 F 93 C 3 5 F to
79 C
-18 C to
125 F 52 C 3 F to
+38 C
-18 C to
125 F 52 C 3 F to
+38 C
Throttling Range Bulb Size
1 9 C to 20 C
1.7 C to
16.7 C
1.7 C to
16.7 C
1 9 C to 20 C
1.7 C to
16.7 C
1.7 C to
16.7 C
7/64 in. diameter x 24 ft. long
1/2 in. diameter x 4 3/16 in. long
1/8 in. diameter x 76 3/8 in. long
1/8 in. diameter x 76 3/8 in. long
7/64 in. diameter x 24 ft. long
1/8 in. diameter x 76 3/8 in. long
36 F
10 F
10 F
36 F
30 F
30 F
2 8 mm diameter x 7 3 m long
13 mm diameter x 107 mm long
3 mm diameter x 1 9 m long
3 mm diameter x 1 9 m long
2 8 mm diameter x 7 3 m long
3 mm diameter x 1 9 m long
Remote Bulb Controller Accessories
Product Number Description
107323A/U Remote Bu b Shield Assembly, 3/8 in. diameter bulbs, < 5 in. long
Capillary Length
24 ft 7.3 m One 135 Ohm
5 ft 1.5 m One 135 Ohm
5 ft 1.5 m One 135 Ohm
5 ft 1.5 m One 135 Ohm
24 ft 7.3 m One 135 Ohm
20 ft 6.1 m One 135 Ohm
Analog Output Sensor Element Includes
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Potentiometer
Copper averaging element
Copper bulb 107324A Duct
Copper fast response element
Copper fast response element
Copper averaging element
Copper fast response element
Bulb holder
131524A duct coil holder
131524A duct coil holder
131524A duct coil holder
M17284A
107323A
Commercial
107324A/U Capillary Holder Assembly for duct insertion, 8 3/8 in. long
107408/U Heat Conductive Compound, 4 ounces
112620AA/U Well Assembly., 3 3/4 in. (95 mm) insertion, 3/8 in. (10 mm) diameter, copper
112620BB/U Well Assembly., 5 1/2 in. (140 mm) insertion, 3/8 in. (10 mm) diameter, copper
112622AA/U Well Assembly., 4 in. (102 mm) insertion, 1/2 in. (13 mm) diameter, copper
112624AA/U Well Assembly., 4 3/4 in. (121 mm) insertion, 1/2 in. (13 mm) diameter, stainless steel
112628AA/U Well Assembly., 4 3/4 in. (121 mm) insertion, 1/2 in. (13 mm) diameter, stainless steel
112630AA/U Well Assembly., 4 1/4 in. (108 mm) insertion, 1/2 in. (13 mm) diameter, copper
112632AA/U Well Assembly., 4 1/4 in. (108 mm) insertion, 1/2 in. (13 mm) diameter, stainless steel
112634AA/U Well Assembly., 4 1/4 in. (108 mm) insertion, 1/2 in. (13 mm) diameter, copper
131524A/U Capillary Holder Assembly., 8 3/8 in. long, duct insertion
M17275A
Components
107324A
M17401A
193987GA/U Encapsulated platinum sensing element used with the T7075 and T775. 2 5/8 in long,
3/8 in diameter, 6 in. leads.
70-6910 359