Apex
Flexibility that meets
your requirements

Apex
Easy to Install
• Sensor can be remotely mounted
up to 100m from the transmitter
• On board relays allow for local
audible / visual alarms
• Strong integral 316 STST mounting bracket
• Large easy access cable entries
• Easy access terminal blocks
• Wide range of accessories
Easy to Use
• Intuitive menu operating system
• Clear on screen instructions guide user
• Simple four button operation
• Multiple language options
• Transmitter recognises new
sensor cartridges
• Easy to change gas types
• Large clear backlit graphical LCD display
Easy to Maintain
• Simple plug in under power
sensor cartridge
• Smart cartridges are supplied pre-calibrated
• Common sensor and transmitter for all
gas types
• Simple filter replacement
Apex takes the best elements of gas detection
design and combining them into one unit.
Apex provides the highest performance,
installation flexibility, a wide range of
accessories and a choice of communication
outputs. All this is provided in a package
that is easy to install, operate and maintain.
Typical applications include:
Petrochemical
Exploration drilling rigs, production platforms,
FPSOs, oil and gas terminals, chemical plants,
oil and gas tankers
Heavy Industrial
Steel manufacture, ship building
Manufacturing
Automotive, glass and ceramics, aerospace,
printing and coating, cosmetics
Pharmaceutical
Research labs, solvent storage areas, process
areas, demineralisation plants
Transmitter
The robust hazardous area approved Apex
transmitter housing and mounting bracket is
made from 316 Stainless Steel. It has a large
backlit LCD display, simple 4 button operation,
3 fully configurable relay outputs and selectable
sink, source or isolated 4-20mA signal.
The sensor and transmitter is common for all
gas types.
Sensor
The Apex Sensor can be mounted directly on
the transmitter or remotely up to 100m away.
The same sensor is used for both catalytic and
electrochemical type sensor cartridges.
Sensor
Smart Cartridge
Smart cartridge
The sensor can be fitted with a choice of over
40 toxic gas ranges and wide range of detectable
flammable gases. Each cartridge is pre-calibrated
and simply plugs into the sensor. The Intrinsically
Safe design allows cartridges to be changed with
the unit under power. The transmitter recognises
a newly fitted sensor cartridge and automatically
reads all the configuration information from it.
Transmitter

General Specication
General Specification
Power Supply 24VDC nominal (18-32VDC)
Power Consumption (typical) Apex 3W toxic, 4.6W catalytic
Outputs
Relay outputs A1, A2 and Fault 2A at 30VDC* selectable normally open or normally closed and normally energised or normally de-energised
Analogue signal 4-20mA sink, source or isolated output
Digital output LonWorks (optional) - only available on ATEX certified version
Material and Weight 316 Stainless Steel 5.25kg (11.55lbs)
Accuracy Baseline ±3%, at 50% FSD ±4%
Repeatability ±2% at 50% FSD
Linearity <5% FSD
Response Time (typical)
Catalytic T50 <5 seconds, T90 <10 seconds
Toxic T50 <12 seconds, T90 <30 seconds
Stability (typical)
Temperature <±5% FSD (zero), <±5% FSD (span)
Time <±3% FSD / year (zero), <±4% FSD / year (span)
Operating Temperature -40°C to +65°C (-40°F to +150°F).
Operating Humidity 0-99% (non condensing)
Environmental Protection IP66 / 67 to BS EN60529:1992 (Equiv. NEMA 4X / NEMA 6)
Approvals CE Approved to all applicable European directives. EMC EN50270: 1999 type 2
Performance Standards Exam (DMT) EN50054 / 50057 / 50271. CSA C22.2 No.152 (with cartridge 2110B3754)
Certification ATEX II 2 GD EEx d ia IIC, CSA Class 1, Division 1 groups B, C and D C22.2 No.152
Available Gases and Ranges *
Gas Formula Ranges Cell type
Flammable
Various 0-100% LEL or 0-10% LEL CAT
Ammonia NH
Arsine AsH
Boron Trichloride BCI
Bromine BR
Carbon Monoxide CO 0-100ppm, 0-200ppm or 0-500ppm ECC
Chlorine Cl
Chlorine Dioxide ClO
Diborane B
Dichlorosilane SiH
Ethylene Oxide C
Fluorine F
Germane GeH
Hydrogen H
Hydrogen Bromide HBr 0-12ppm ECC
Hydrogen Chloride HCl 0-20ppm ECC
Hydrogen Cyanide HCN 0-20ppm ECC
Hydrogen Fluoride HF 0-12ppm ECC
Hydrogen Sulphide H
Nitric Oxide NO 0-100ppm ECC
Nitrogen Dioxide NO
Oxygen O
Ozone O
Phosphine PH
Propylene Oxide C
Silane SiH
Sulphur Dioxide SO
CAT- Electrocatalytic, ECC- Electrochemical Cell.
* For other gases and ranges not listed contact Honeywell Analytics.
* Oxygen detection products must only be used to detect oxygen depletion in air.
Operating temperature of electrochemical cell cartridges is cell dependent. LCD display operates over -20°C to +65°C
UL Class 1, Division 1 groups B, C and D, and Class 1, Zone 1 AExd [ia] IIC
ATEX and UL T4 -40°C to +80°C (-40°F to +176°F), T5 -40°C to +55°C (-40°F to +131°F)
CSA T4 -40°C to +75°C (-40°F to +167°F), T5 -40°C to +55°C (-40°F to +131°F)
* CSA / UL rating 1A at 28VDC
0-50ppm, 0-100ppm, 0-400ppm or 0-1000ppm ECC
3
0-0.2ppm ECC
3
0-6ppm ECC
3
0-0.4ppm ECC
2
0-2ppm, 0-5ppm or 0-15ppm ECC
2
2
2H6
0-10ppm ECC
2Cl2
O 0-25ppm ECC
2H4
0-4ppm ECC
2
0-0.8ppm ECC
4
0-1000ppm ECC
2
S 0-15ppm, 0-20ppm, 0-50ppm or 0-100ppm ECC
2
0-12ppm ECC
2
0-21% V / V ECC
2
3
0-1.2ppm ECC
3
O 0-50ppm ECC
3H6
0-2ppm, 0-20ppm ECC
4
0-8ppm, 0-10ppm, 0-15ppm, 0-50ppm ECC
2
0-0.4ppm ECC
0-0.4ppm ECC
0-0.4ppm ECC

Contact Honeywell Analytics:
Find out more
www.honeywellanalytics.com
Europe, Middle East, Africa, India
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Our Product Range
Contact Honeywell Analytics:
Find out more
www.honeywellanalytics.com
Europe, Middle East, Africa, India
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Americas
Honeywell Analytics Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
Contact Honeywell Analytics:
Find out more
www.honeywellanalytics.com
Europe, Middle East, Africa, India
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Americas
Honeywell Analytics Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
Asia Pacific
Honeywell Analytics Asia Pacific
#508, Kolon Science Valley (I)
187-10 Guro-Dong, Guro-Gu
Seoul, 152-050,
Korea
Tel: +82 (0)2 2025 0300
Fax: +82 (0)2 2025 0329
analytics.ap@honeywell.com
Contact Honeywell Analytics:
Find out more
www.honeywellanalytics.com
Europe, Middle East, Africa, India
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Americas
Honeywell Analytics Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
www.honeywell.com
Technical Services
ha.emea.service@honeywell.com
Asia Pacific
Honeywell Analytics Asia Pacific
#508, Kolon Science Valley (I)
187-10 Guro-Dong, Guro-Gu
Seoul, 152-050,
Korea
Tel: +82 (0)2 2025 0300
Fax: +82 (0)2 2025 0329
analytics.ap@honeywell.com
Fixed Gas Monitoring
Honeywell Analytics offers a wide range
of fixed gas detection solutions for a
diverse array of industries and applications
including: Commercial properties, industrial
applications, semiconductor manufacturers,
energy plants and petrochemical sites.
Detection of flammable, oxygen and toxic »
gases (including exotics)
Innovative use of 4 core sensing
»
technologies – paper tape,
electrochemical cell, catalytic bead
and infrared
Capability to detect down to Parts Per
»
Billion (ppb) or Percent by Volume (%v/v)
Cost effective regulatory compliance
»
solutions
Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions.
Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations,
standards, and guidelines. This publication is not intended to form the basis of a contract.
H_Apex_DS0284_V6_EMEA
10/08
© 2008 Honeywell Analytics
Portable Gas Monitoring
When it comes to personal protection from
gas hazards, Honeywell Analytics has a wide
range of reliable solutions ideally suited for
use in confined or enclosed spaces.
These include:
Detection of flammable, oxygen and »
toxic gases
Single gas personal monitors – worn by
»
the individual
Multi-gas portable gas monitors – used
»
for confined space entry and regulatory
compliance
Multi-gas transportable monitors – used
»
for temporary protection of area
during site construction and
maintenance activities
Technical Services
At Honeywell Analytics, we believe in the
value of great service and customer care.
Our key commitment is providing complete
and total customer satisfaction. Here are just
a few of the services we can offer:
Full technical support »
Expert team on hand to answer »
questions and queries
Fully equipped workshops to ensure
»
quick turnaround on repairs
Comprehensive service engineer network
»
Training on product use and maintenance »
Mobile calibration service »
Customised programmes of »
preventative/corrective maintenance
Extended warranties on products
»
11137