Honeywell PCR 310, PCR 300RC, PCR 410, PCR 300 PRODUCT DATA

Series PCR-300/-310/-410/-300RC
ELECTRONIC COLD STORE CONTROLS
PRODUCT DATA
Features
User friendly programming
Compressor control with delayed start-up
Evaporator fan control; fan in combination with
compressor, operating continuously or switched via the evaporator temperature.
Defrost control for electrical heating or hot-gas
defrosting; initiated via programmable time intervals, at PCR-300RC by real-time clock
Alarm output (not for PCR-310)
PCR-300
PCR-310
Red digital display, good visibility
Module housing for 35 mm standard DIN rail at PCR-
300 and PCR-300RC
Snap-in installation housing at PCR-310 and PCR-410
for aperture 28.5 x 70.5 mm
Mains transformer integrated at PCR-300, PCR-300RC
External transformer at PCR-310, PCR-410
2 PTC sensors with stainless steel sleeves for room
temperature and defrost termination
Specification (1)
Application
PCR-300, PCR-310, PCR-410 and PCR-300RC are microprocessor-controlled cold store controls for refrigeration and deep freeze systems.
The control switch the compressor, evaporator fan and the defrost heating depending on the cold store temperature and the adjusted parameters.
Material
Housing
ABS-plastic, self-extinguishing
Power supply
Power consumption
Control performance
Display
Resolution
Display accuracy
Measuring range
Inputs
PCR-300, PCR-300RC
mains transformer installed: 230 V, ±10 %, 50/60 Hz
PCR-310, PCR-410 12 V AC ±10%, 50/60 Hz or 12 V DC ±10% external Transformer TR-310: Prim.: 230 V AC ±10%, 50/60 Hz Sec.: 12 V AC
2.5 Watt
on/off
3-digit, 7-segment, LED red, height 14.2 mm
1 K
±0.5 K internally, ±1 digit at 25 °C
-55 °C to +50 °C
2 PTC sensors
Continued on page 2
Copyright © 2009 Honeywell GmbH • Subject to change without notice EN0H-1923GE23 R0709
SERIES PCR-300
Specification (2)
Outputs
compressor: 1 relay with
changeover contact, 8 A, 230 V AC, resistive load
evaporator fan: 1 relay with N.O. contact, 8 A (5 A PCR-300RC), 230 V AC, resistive load
defrost heating: 1 relay with N.O. contact, 8 A (5 A PCR-300RC), 230 V AC, resistive load
alarm:
PCR-300, PCR-300RC: Opto­bidirectional triode thyristor, 250 VAC, min. load 40 mA, max. load 80 mA
PCR-410: 1 relay with N.O. contact, 8 A, 230 V AC, resistive load
Sensor
Ambient temperature/humidity
Data back up
Connectors
Protective rating
PTC sensor, cable length 2.5 m, accuracy ±2 %
range of use:
-30 °C to +80 °C cable not fixed
-40 °C to +80 °C cable fixed
in operation: 0° to 50 °C, 30 to 85 % R.H. excluding dew
in storage:
-20 °C to +80 °C
Non-volatile memory EEPROM, Real time clock with back up battery (PCR-300RC)
250V / 10 A screw-type terminal strips, max. 1.5 mm²
Housing: IP 20 front panel: IP 52, protection class 2
Dimensions and Weight
Dimensions of housing (mm) Type
W H D
PCR-300 70 85 61 approx. 0.42
PCR-310 Transformer
PCR-410 Transformer
PCR-300RC 70 85 61 approx. 0.42
70 52
70 52
32 47
32 47
74 34
74 34
Weight
(kg)
approx. 0.52
approx. 0.52
Installation
Operate only in dry places
Snap-in installation housing:
Fit unit in a recess 28.5 x 70.5 mm
maximum wall thickness: 22 mm
Secure housing with the mounting frame
4 DIN standard modular housing:
Open out the side mounting tabs
Clip the unit on to 35 mm rail
press tabs in again
Respect the wiring diagram
Tighten screws of connectors carefully